Pitco Frialator L22-303 Key Locations and Functions, To turn the appliance OFF, To start a cook

Page 4

I8 Water Cooker Computer Service

Pitco P/N PP11375

1.0Key Locations and Functions:

Program Key Temperature Key Clock Key

Key Indicators

1

0

2

3

4

5

6

7

8

9

Key Indicators

Product Keys

8 Digit Display

Product Keys

1.1To turn the appliance ON:

If power is applied to the appliance(plugged in) and the control is off, the display will be blank. Turn on the control by pressing the power on/off switch located on the right side of the control to the ON position. The control will then briefly display the software version number, and then display either [READY], [ACT xxx’F] (where xxx is the current vat temperature) or [FILLING] if the appliance is being filled with water.

1.2To turn the appliance OFF:

Press the power on/off switch to the OFF position. The control display will be blank.

1.3To start a cook:

When the control display shows either [READY] or [ACT xxx’F], press the desired product key. For example, press product key 4 to start cook timer 4. The key indicator above the product key will begin to flash, and the cook timer should appear on the computer display. If multiple cook timers are running, the cook timer with the least amount of time remaining will be displayed.

1.4To cancel a cook:

4

Press the product key to cancel a running cook timer. If there are no other cook timers running, the computer will return to normal operation and display either [READY] or [ACT xxx’F] (where

xxxis the current vat temperature).

1.5To Check Actual and Set Temperatures:

Press the temperature key to check the actual vat temperature. The control will momentarily display [ACT xxx’F] (where xxx is the current vat temperature) and then return to normal operation.

4

L22-303 Rev 0 (01/07)

Image 4
Contents I8 Water Cooker Computer Table of Contents Control Alarm Displays To cancel a cook To Check Actual and Set TemperaturesKey Locations and Functions To turn the appliance OFFTo set the Cook Temperature To enter Level 1 Programmingstore managerShake Time To enter Level 2 Options Programmingstore managerHold Time Fahrenheit or Celcius Temperature Display Password SettingsBeeper Volume Setting Xxx’F, or FillingControl or Timer Mode Setting To Enter Level 3 Service Programmingservice technicianOffset Temperature Setting Cancel Delay Setting Minimum On Cycle Time SettingCancel Type Setting Diagnostics MenuDrain SwitchDVI Input Left Basket LiftLBL OutputRight Basket LiftRBL Output Heat DemandHD OutputRecovery Test Value More Service Menu OptionsLow Ready Level Adjustment High Ready Level AdjustmentLow Dead Band Adjustment High Dead Band AdjustmentControl Temperature Average Setting Display Temperature Average SettingControl Alarm Displays Minimum Fill Time SettingFilling Pilot Flame Sense Timer Adjustment Open Probe AlarmHigh Temperature Alarm Drain Valve AlarmHeat Failure Alarm System Failure AlarmElectrical ConnectionsJ1 Connection Type NominalResistance Probe Resistance ChartTemp Ohms Physical Dimensions Page Page L22-303 Rev 0 01/07