Pitco Frialator L22-303 service manual Table of Contents

Page 2

I8 Water Cooker Computer Service

Pitco P/N PP11375

Table of Contents

1.0

Key Locations and Functions:

4

 

1.1

To turn the appliance ON:

4

 

1.2

To turn the appliance OFF:

4

 

1.3

To start a cook:

4

 

1.4

To cancel a cook:

4

 

1.5

To Check Actual and Set Temperatures:

4

 

1.6

To view the current Cook, Shake and Hold timer settings:

5

2.0

To enter Level 1 Programming(store manager):

5

 

2.1

To set the cook Temperature:

5

 

2.2

To change Cook, Shake and Hold timer settings:

5

 

 

2.2.1

Cook Time:

5

 

 

2.2.2

Shake Time:

6

 

 

2.2.3

Hold Time:

6

3.0

To enter Level 2 Options Programming(store manager):

6

 

3.1

Fahrenheit or Celsius Temperature Display:

7

 

3.2

Password Settings:

7

 

3.3

Beeper Volume Setting:

7

 

3.4

Language Selection:

7

 

3.5

Control or Timer Mode Setting:

8

4.0

To enter Level Service Programming(service technician):

8

 

4.1

Offset Temperature Setting:

8

 

4.2

Cancel Delay Setting:

9

 

4.3

Minimum On Cycle Time Setting:

9

 

4.4

Cancel Type Setting:

9

 

4.5

Diagnostics Menu:

9

 

 

4.5.1 Left Basket Lift (LBL) Output:

10

 

 

4.5.2 Right Basket Lift (RBL) Output:

10

 

 

4.5.3 Heat Demand (HD) Output:

10

 

 

4.5.4 Side On (SO) or Transfer Output:

10

 

 

4.5.5 Drain Switch (DVI) Input:

10

 

 

4.5.6 Heat Feedback (HFB) Input:

10

 

 

4.5.7 Fill Done Input:

10

2

L22-303 Rev 0 (01/07)

Image 2
Contents I8 Water Cooker Computer Table of Contents Control Alarm Displays Key Locations and Functions To cancel a cookTo Check Actual and Set Temperatures To turn the appliance OFFTo set the Cook Temperature To enter Level 1 Programmingstore managerHold Time To enter Level 2 Options Programmingstore managerShake Time Beeper Volume Setting Fahrenheit or Celcius Temperature DisplayPassword Settings Xxx’F, or FillingOffset Temperature Setting To Enter Level 3 Service Programmingservice technicianControl or Timer Mode Setting Cancel Type Setting Cancel Delay SettingMinimum On Cycle Time Setting Diagnostics MenuRight Basket LiftRBL Output Drain SwitchDVI InputLeft Basket LiftLBL Output Heat DemandHD OutputLow Ready Level Adjustment Recovery Test ValueMore Service Menu Options High Ready Level AdjustmentControl Temperature Average Setting Low Dead Band AdjustmentHigh Dead Band Adjustment Display Temperature Average SettingFilling Pilot Flame Sense Timer Adjustment Control Alarm DisplaysMinimum Fill Time Setting Open Probe AlarmHeat Failure Alarm High Temperature AlarmDrain Valve Alarm System Failure AlarmElectrical ConnectionsJ1 Connection Type NominalTemp Ohms Probe Resistance ChartResistance Physical Dimensions Page Page L22-303 Rev 0 01/07