Pitco Frialator L22-303 High Temperature Alarm, Drain Valve Alarm, Heat Failure Alarm

Page 14

I8 Water Cooker Computer Service

Pitco P/N PP11375

5.2High Temperature Alarm:

[HIGH TMP]. This alarm will occur if the vat temperature exceeds the set temperature value by 35°F. If a high vat temperature alarm occurs, all heating and cooking functions are suspended.

5.3Drain Valve Alarm:

[DRAINING] and [TURN OFF] (alternating). This alarm message will appear on the control display if the drain valve on the appliance is opened while the control is ON. All heating and cooking functions are suspended if this alarm occurs.

5.4Heat Failure Alarm:

[HEAT] and [FAILURE] (alternating). This alarm will occur if the control does not sense a pilot flame or if the high limit switch has tripped and needs resetting. All heating and cooking functions are suspended if this alarm occurs.

5.5System Failure Alarm:

[SYSTEM]. This alarm will occur if the control detects a shorted temperature probe. All heating and cooking functions are suspended if this alarm occurs.

14

L22-303 Rev 0 (01/07)

Image 14
Contents I8 Water Cooker Computer Table of Contents Control Alarm Displays Key Locations and Functions To cancel a cookTo Check Actual and Set Temperatures To turn the appliance OFFTo set the Cook Temperature To enter Level 1 Programmingstore managerHold Time To enter Level 2 Options Programmingstore managerShake Time Beeper Volume Setting Fahrenheit or Celcius Temperature DisplayPassword Settings Xxx’F, or FillingOffset Temperature Setting To Enter Level 3 Service Programmingservice technicianControl or Timer Mode Setting Cancel Type Setting Cancel Delay SettingMinimum On Cycle Time Setting Diagnostics MenuRight Basket LiftRBL Output Drain SwitchDVI InputLeft Basket LiftLBL Output Heat DemandHD OutputLow Ready Level Adjustment Recovery Test ValueMore Service Menu Options High Ready Level AdjustmentControl Temperature Average Setting Low Dead Band AdjustmentHigh Dead Band Adjustment Display Temperature Average SettingFilling Pilot Flame Sense Timer Adjustment Control Alarm DisplaysMinimum Fill Time Setting Open Probe AlarmHeat Failure Alarm High Temperature AlarmDrain Valve Alarm System Failure AlarmElectrical ConnectionsJ1 Connection Type NominalTemp Ohms Probe Resistance ChartResistance Physical Dimensions Page Page L22-303 Rev 0 01/07