I8 Water Cooker Computer Service
Pitco P/N PP11375
5.2High Temperature Alarm:
[HIGH TMP]. This alarm will occur if the vat temperature exceeds the set temperature value by 35°F. If a high vat temperature alarm occurs, all heating and cooking functions are suspended.
5.3Drain Valve Alarm:
[DRAINING] and [TURN OFF] (alternating). This alarm message will appear on the control display if the drain valve on the appliance is opened while the control is ON. All heating and cooking functions are suspended if this alarm occurs.
5.4Heat Failure Alarm:
[HEAT] and [FAILURE] (alternating). This alarm will occur if the control does not sense a pilot flame or if the high limit switch has tripped and needs resetting. All heating and cooking functions are suspended if this alarm occurs.
5.5System Failure Alarm:
[SYSTEM]. This alarm will occur if the control detects a shorted temperature probe. All heating and cooking functions are suspended if this alarm occurs.
14 |