Pitco Frialator L22-303 Left Basket LiftLBL Output, Right Basket LiftRBL Output, Fill Done Input

Page 10

I8 Water Cooker Computer Service

Pitco P/N PP11375

connector pin. Controller inputs can be verified by the ON or OFF state of the key indicator above the appropriate product key.

With the control display showing [SERVICE ], press product key 5 to enter into the diagnostics menu. The control display will show either [D CLOSED] or [D OPEN] depending on whether the drain switch is open or closed. Press the appropriate product key listed below to test the input/output assigned to that key:

4.5.1Left Basket Lift(LBL) Output:

Press product key 1 to toggle this output ON or OFF. The control display will show [L BASKET].

5

1

4.5.2Right Basket Lift(RBL) Output:

Press product key 2 to toggle this output ON or OFF. The control display will show [R BASKET].

4.5.3Heat Demand(HD) Output:

Press and hold product key 3 to turn this output ON. Release the key to turn this output OFF. The control display will show [HEAT DEM].

2

3

4.5.4Side On(SO) or Transfer Output:

Press product key 4 to toggle this output ON or OFF. The control display will show [TRANSFER].

4

4.5.5Drain Switch(DVI) Input:

Press product key 5 to view the state of the drain switch input. The control display will show either [D CLOSED] or [D OPEN] depending on whether the drain switch is open or closed.

5

4.5.6Heat Feedback(HFB) Input:

Press product key 7 to view the state of the heat feedback input. The control display will show either [FB ON] or [FB OFF] depending on whether a heat feedback signal is present or not.

4.5.7Fill Done Input:

Press product key 8 to view the state of the fill done input. The control will display either [NO FILL] or [FILL] depending on whether a fill signal is present or not.

Press the program key to exit it out of this menu option. The display will now show

[SERVICE ]. Continue on to the remaining service menu options below, or press the program key twice to return to normal operation(display shows either [READY], [ACT xxx’F], or [FILLING ]).

7

8

10

L22-303 Rev 0 (01/07)

Image 10
Contents I8 Water Cooker Computer Table of Contents Control Alarm Displays Key Locations and Functions To cancel a cookTo Check Actual and Set Temperatures To turn the appliance OFFTo set the Cook Temperature To enter Level 1 Programmingstore managerShake Time To enter Level 2 Options Programmingstore managerHold Time Beeper Volume Setting Fahrenheit or Celcius Temperature DisplayPassword Settings Xxx’F, or FillingControl or Timer Mode Setting To Enter Level 3 Service Programmingservice technicianOffset Temperature Setting Cancel Type Setting Cancel Delay SettingMinimum On Cycle Time Setting Diagnostics MenuRight Basket LiftRBL Output Drain SwitchDVI InputLeft Basket LiftLBL Output Heat DemandHD OutputLow Ready Level Adjustment Recovery Test ValueMore Service Menu Options High Ready Level AdjustmentControl Temperature Average Setting Low Dead Band AdjustmentHigh Dead Band Adjustment Display Temperature Average SettingFilling Pilot Flame Sense Timer Adjustment Control Alarm DisplaysMinimum Fill Time Setting Open Probe AlarmHeat Failure Alarm High Temperature AlarmDrain Valve Alarm System Failure AlarmElectrical ConnectionsJ1 Connection Type NominalResistance Probe Resistance ChartTemp Ohms Physical Dimensions Page Page L22-303 Rev 0 01/07