Pitco Frialator L22-303 service manual Probe Resistance Chart, Temp Ohms

Page 16

I8 Water Cooker Computer Service

Pitco P/N PP11375

7.0 Probe Resistance Chart:

Probe Resistance in 5°F Increments.

Probe

Probe

Resistance

 

Probe

Probe

Resistance

 

Probe

Probe

Resistance

Temp

Temp

 

Temp

Temp

 

Temp

Temp

(Ohms)

 

(Ohms)

 

(Ohms)

(°F)

(°C)

 

(°F)

(°C)

 

(°F)

(°C)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

-12.2

562734

 

175

79.4

11719

 

340

171.1

1058.23

15

-9.4

483875

 

180

82.2

10716

 

345

173.9

998.09

20

-6.7

417167

 

185

85.0

9812

 

350

176.7

942.00

25

-3.9

360589

 

190

87.8

8995

 

355

179.4

889.67

30

-1.1

312474

 

195

90.6

8255

 

360

182.2

840.78

35

1.7

271446

 

200

93.3

7586

 

365

185.0

795.10

40

4.4

236370

 

205

96.1

6979

 

370

187.8

752.38

45

7.2

206311

 

210

98.9

6427

 

375

190.6

712.41

50

10.0

180491

 

215

101.7

5926

 

380

193.3

674.95

55

12.8

158252

 

220

104.4

5470

 

385

196.1

639.87

60

15.6

139055

 

225

107.2

5055

 

390

198.9

606.96

65

18.3

122489

 

230

110.0

4675

 

395

201.7

576.09

70

21.1

108051

 

235

112.8

4329

 

400

204.4

547.09

75

23.9

95539

 

240

115.6

4013

 

405

207.2

519.86

80

26.7

84644

 

245

118.3

3723

 

410

210.0

494.24

85

29.4

75136

 

250

121.1

3458

 

415

212.8

470.16

90

32.2

66823

 

255

123.9

3214

 

420

215.6

447.49

95

35.0

59540

 

260

126.7

2991

 

425

218.3

426.13

100

37.8

53146

 

265

129.4

2785

 

430

221.1

406.02

105

40.6

47523

 

270

132.2

2597

 

435

223.9

387.04

110

43.3

42569

 

275

135.0

2422

 

440

226.7

369.14

115

46.1

38195

 

280

137.8

2262

 

445

229.4

352.24

120

48.9

34328

 

285

140.6

2113.9

 

450

232.2

336.29

125

51.7

30902

 

290

143.3

1977.3

 

455

235.0

321.21

130

54.4

27862

 

295

146.1

1851.0

 

460

237.8

306.94

135

57.2

25161

 

300

148.9

1734.3

 

465

240.6

293.46

140

60.0

22755

 

305

151.7

1626.1

 

470

243.3

280.69

145

62.8

20610

 

310

154.4

1525.9

 

475

246.1

268.61

150

65.6

18695

 

315

157.2

1433.0

 

480

248.9

257.15

155

68.3

16981

 

320

160.0

1346.7

 

485

251.7

246.30

160

71.1

15446

 

325

162.8

1266.6

 

490

254.4

236.00

165

73.9

14069

 

330

165.6

1192.1

 

495

257.2

226.24

170

76.7

12823

 

335

168.3

1122.8

 

500

260.0

216.96

NOTE: The resistance of either probe lead measured to the frame of the appliance should read as an open on a meter(resistance >= 1Mohm).

16

L22-303 Rev 0 (01/07)

Image 16
Contents I8 Water Cooker Computer Table of Contents Control Alarm Displays To cancel a cook To Check Actual and Set TemperaturesKey Locations and Functions To turn the appliance OFFTo set the Cook Temperature To enter Level 1 Programmingstore managerShake Time To enter Level 2 Options Programmingstore managerHold Time Fahrenheit or Celcius Temperature Display Password SettingsBeeper Volume Setting Xxx’F, or FillingControl or Timer Mode Setting To Enter Level 3 Service Programmingservice technicianOffset Temperature Setting Cancel Delay Setting Minimum On Cycle Time SettingCancel Type Setting Diagnostics MenuDrain SwitchDVI Input Left Basket LiftLBL OutputRight Basket LiftRBL Output Heat DemandHD OutputRecovery Test Value More Service Menu OptionsLow Ready Level Adjustment High Ready Level AdjustmentLow Dead Band Adjustment High Dead Band AdjustmentControl Temperature Average Setting Display Temperature Average SettingControl Alarm Displays Minimum Fill Time SettingFilling Pilot Flame Sense Timer Adjustment Open Probe AlarmHigh Temperature Alarm Drain Valve AlarmHeat Failure Alarm System Failure AlarmElectrical ConnectionsJ1 Connection Type NominalResistance Probe Resistance ChartTemp Ohms Physical Dimensions Page Page L22-303 Rev 0 01/07