Pitco Frialator L22-303 service manual To Enter Level 3 Service Programmingservice technician

Page 8

I8 Water Cooker Computer Service

Pitco P/N PP11375

3.5Control or Timer Mode Setting:

This control can operate in one of two basic modes, Control or Timer mode. The default mode setting is Control mode, and is the setting for normal operation. In this mode, the cook timers are active and the heat control outputs are enabled to control the heating of the vat. In Timer mode, the cook timers are active, but the heat control outputs are disabled.

NOTE: Do not use the Timer mode setting on Solstice fryer models.

With the control display showing [SELECT ], press product key 7. The display will show the current setting of either [CONTROL ] or [TIMER ]. Press product key 0 to scroll between the two options. Press the program key to save this setting. The control display will show [PROGRAM ]. Press product key 0 to select more options below(display shows [SELECT ]) or press the program key to return to normal operation(display shows either [READY], [ACT xxx’F], or [FILLING ]).

7

4.0To Enter Level 3 Service Programming(service technician):

Note: The factory default setting for this control does not require an operator password to be entered. However, the operator password requirement and value may be changed in section 3.2. Entry of a password when NOT required will not interfere with the programming process.

While there are no cook timers running, and the control display shows either [READY], [ACT xxx’F], or [FILLING ], press the program key. If the control displays [PASS ], enter the manager password(or the default manager password 6684) using the product

keys 0-9. The control display will show [PROGRAM ]. To enter into the Level 3

6

 

Service Menu, key in the service password of 6685 using the product keys 0-9.

 

 

The control display will show [SERVICE ].

 

 

6

8

5

The key indicators that light up will have options that can be adjusted. Any key indicators that do not light up do not have options that can be adjusted.

All of the Level 3 Service Menu programming options shown below must begin with the control displaying this prompt [SERVICE ].

4.1Offset Temperature Setting:

This setting allows the displayed temperature value to be offset(degrees F) to reflect the true center vat temperature while reading the probe tip temperature. The default value is zero. A setting of zero for the temperature offset will make the displayed temperature equal to the probe temperature. The maximum offset value that can be entered is 20.

With the control display showing [SERVICE ], press product key 1. The display will show

 

 

1

 

 

 

 

 

[OFF xx F], where xx is the current offset value. Enter the new offset value using the

 

 

 

 

 

 

product keys 0-9. Press the program key to save this setting. The control display will

 

 

 

 

 

show either [POSITIVE] or [NEGATIVE], indicating that the offset value is positive or negative. Press product key 0 to scroll between these two options. Press the program key to save this setting. The display will now show [SERVICE ]. Continue on to the remaining service menu options below, or press the program key twice to return to normal operation(display shows either [READY], [ACT xxx’F], or [FILLING ]).

8

L22-303 Rev 0 (01/07)

Image 8
Contents I8 Water Cooker Computer Table of Contents Control Alarm Displays To cancel a cook To Check Actual and Set TemperaturesKey Locations and Functions To turn the appliance OFFTo set the Cook Temperature To enter Level 1 Programmingstore managerHold Time To enter Level 2 Options Programmingstore managerShake Time Fahrenheit or Celcius Temperature Display Password SettingsBeeper Volume Setting Xxx’F, or FillingOffset Temperature Setting To Enter Level 3 Service Programmingservice technicianControl or Timer Mode Setting Cancel Delay Setting Minimum On Cycle Time SettingCancel Type Setting Diagnostics MenuDrain SwitchDVI Input Left Basket LiftLBL OutputRight Basket LiftRBL Output Heat DemandHD OutputRecovery Test Value More Service Menu OptionsLow Ready Level Adjustment High Ready Level AdjustmentLow Dead Band Adjustment High Dead Band AdjustmentControl Temperature Average Setting Display Temperature Average SettingControl Alarm Displays Minimum Fill Time SettingFilling Pilot Flame Sense Timer Adjustment Open Probe AlarmHigh Temperature Alarm Drain Valve AlarmHeat Failure Alarm System Failure AlarmElectrical ConnectionsJ1 Connection Type NominalTemp Ohms Probe Resistance ChartResistance Physical Dimensions Page Page L22-303 Rev 0 01/07