PB Heat MIH manual 3b Gas Valve and Pilot Intermittent

Page 39

REPAIR PARTS

Figure 11.3a:

Gas Valve and Pilot – Standing Pilot

Figure 11.3b: Gas Valve and Pilot – Intermittent

 

 

(Continuous Ignition)

 

 

Ignition

 

 

 

 

Table 11.3a:

Manifold/Gas Train (MI – Intermittent Ignition)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Item

 

Description

Part Selection

 

MI-03

MI-04

MI-05

MI-06

MI-07

MI-08

MI-09

No.

 

Information

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

Steel Burner

Specify quantity

 

51537

51537

51537

51537

51537

51537

51537

 

 

 

 

 

 

 

 

 

 

 

6

Steel Burner w/ Pilot Clip

1 per boiler

 

51539

51539

51539

51539

51539

51539

51539

 

 

 

 

 

 

 

 

 

 

 

7

Gas Manifold

 

 

50978

50979

50980

50981

50954

50955

50956

 

 

 

 

 

 

 

 

 

 

 

8

Orifice Spud, #48

Natural Gas, 0-2000 ft. (0-610 m)

50894

50894

50894

50894

 

 

 

elevation (specify qty)*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Orifice Spud, #49

Natural Gas, 0-2000 ft. (0-610 m)

 

 

 

 

50895

50895

50895

 

elevation (specify qty)*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Orifice Spud, #56

LP Gas, 0-2000 ft. (0-610 m)

50899

50899

50899

 

 

 

 

 

elevation (specify qty)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Orifice Spud, #57

LP Gas, 0-2000 ft. (0-610 m)

 

 

 

 

50900

50900

50900

 

elevation (specify qty)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

Honeywell SV9501M2700 Gas Valve

Natural Gas

 

51682

51682

51682

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Honeywell SV9501M2064 Gas Valve

LP Gas

 

51691

51691

51691

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Honeywell SV9601M4167 Gas Valve

Natural Gas

 

 

 

 

51683

51683

51683

51683

 

 

 

 

 

 

 

 

 

 

 

 

Honeywell SV9601M4225 Gas Valve

LP Gas

 

 

 

 

51692

51692

51692

51692

 

 

 

 

 

 

 

 

 

 

 

10

Honeywell Q3480B1025 Pilot

Natural Gas

 

51684

51684

51684

51684

51684

51684

51684

 

 

 

 

 

 

 

 

 

 

 

 

Honeywell Q3480B1033 Pilot

LP Gas

 

51685

51685

51685

51685

51685

51685

51685

 

 

 

 

 

 

 

 

 

 

 

 

*For elevations over 2,000 feet above sea level contact PB Heat, LLC.

Table 11.3b: Manifold/Gas Train (MIH – Intermittent Ignition)

Item

Description

Part Selection

MI-03

MI-04

MI-05

MI-06

No.

Information

 

 

 

 

 

 

 

 

 

 

 

 

5

Steel Burner

Specify quantity

51537

51537

51537

51537

 

 

 

 

 

 

 

6

Steel Burner w/ Pilot Clip

1 per boiler

51539

51539

51539

51539

 

 

 

 

 

 

 

7

Gas Manifold

 

50978

50979

50980

50981

 

 

 

 

 

 

 

8

Orifice Spud, #49

Natural Gas, 0-2000 ft. (0-610 m)

50895

50895

50895

50895

elevation (specify qty)*

 

 

 

 

 

 

 

 

 

 

 

 

 

9

Honeywell SV9501M2700 Gas Valve

Natural Gas

51682

51682

51682

 

 

 

 

 

 

 

 

 

Honeywell SV9601M4167 Gas Valve

Natural Gas

 

 

 

51683

 

 

 

 

 

 

 

10

Honeywell Q3480B1025 Pilot

Natural Gas

51684

51684

51684

51684

 

 

 

 

 

 

 

*For elevations over 2,000 feet above sea level contact PB Heat, LLC.

37

Image 39
Contents Series MI/MIH Table of Contents Using this Manual Installation SequenceSpecial Attention Boxes AIR for Combustion and Ventilation PreinstallationAccessibility Clearances Clearance from Combustible ConstructionAir Openings All Air from Indoors on Different Floors Air Openings All Air from Outdoors through Vertical Ducts Planning the Layout Installation SurveyBoiler SET-UP Boiler Supply and Return Water Piping and ControlsParallel Hook-Up with Water Chiller Safety Relief ValveZone Piping with Zone Valves Piping for Zoned SystemsExpansion Tank INDIRECT-FIRED Water HeaterFreeze Protection Vent Damper Installation General VentingIntegral Draft Hood Venting with Vent Damper in Vertical Position Vent Piping and ChimneySeal any unused openings in the common venting system Boiler Removal from Common Venting SystemGas Connection to Boiler GAS PipingMIH Boiler Natural Gas Wiring Controls Zoned System WiringElectrical Sequence of Operation Wiring and Connection Diagram Intermittent Ignition Intermittent Ignition System Operating Sequence Zone Wiring with Zone Valves Completing the Installation START-UP ProceduresValve Tapping and Adjustment Screw Locations Operating Instructions For Your Safety Read Before Lighting Adjustment of GAS Pressure Regulator Adjustment of Pilot GAS FlowControl Descriptions Checking Burner Input CHECK-OUT ProcedureSTART-UP Procedures Troubleshooting Guides TroubleshootingProblem Possible Causes Corrective Actions Intermittent Ignition System Troubleshooting Sequence Maintenance Monthly with Boiler in USE GeneralDaily with Boiler in USE Weekly with Boiler in USEStanding Pilot and Main Burner Flame Annually Before Start of Heating SeasonSeries MI/MIH Boiler Dimensions Boiler Dimensions & RatingsRepair Parts Series MI/MIH GAS Boiler Repair Parts2Manifold Manifold/Gas Train MI Standing Pilot 3b Gas Valve and Pilot Intermittent 4Block/Draft Hood 4a Block/Draft Hood 5Jacket 6Controls/Circulator/Vent Damper Series MI/MIH