REPAIR PARTS

Figure 11.6:Controls/Circulator/Vent Damper

Table 11.6: Controls/Circulator/Vent Damper

Item

Description

MI/MIH

MI/MIH

MI/MIH

MI/MIH

MI-07

MI-08

MI-09

No.

-03

-04

-05

-06

 

 

 

 

 

 

 

 

 

 

 

 

 

23

Honeywell L8148E1182 Limit w/ ³⁄₄Well*

51689

51689

51689

51689

51689

51689

51689

 

 

 

 

 

 

 

 

 

24

Temperature-Pressure Gauge

51774

51774

51774

51774

51774

51774

51774

 

 

 

 

 

 

 

 

 

25

Safety Relief Valve, 30 psi*, Conbraco 10-408-05

50501

50501

50501

50501

50501

50501

50501

 

 

 

 

 

 

 

 

 

 

Safety Relief Valve, 50 psi*, Watts #350

99950

99950

99950

99950

99950

99950

99950

 

 

 

 

 

 

 

 

 

26

Flame Roll-Out Safety Shut-Off Switch

51587

51587

51587

51587

51587

51587

51587

 

 

 

 

 

 

 

 

 

27

Blocked Vent Shut-Off (Spill) Switch – MI Only

90592

90592

90592

90592

90592

90592

90592

 

 

 

 

 

 

 

 

 

27

Blocked Vent Shut-Off (Spill) Switch – MIH Only

90593

90593

90593

90593

90593

90593

90593

 

 

 

 

 

 

 

 

 

28

Vent Damper

90612

90612

90613

90613

90614

90615

90615

 

 

 

 

 

 

 

 

 

 

*Available from distributor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40

Image 42
Contents Series MI/MIH Table of Contents Using this Manual Installation SequenceSpecial Attention Boxes Clearance from Combustible Construction PreinstallationAccessibility Clearances AIR for Combustion and VentilationAir Openings All Air from Indoors on Different Floors Air Openings All Air from Outdoors through Vertical Ducts Installation Survey Planning the LayoutBoiler SET-UP Water Piping and Controls Boiler Supply and ReturnSafety Relief Valve Parallel Hook-Up with Water ChillerPiping for Zoned Systems Zone Piping with Zone ValvesExpansion Tank INDIRECT-FIRED Water HeaterFreeze Protection Vent Damper Installation General VentingIntegral Draft Hood Vent Piping and Chimney Venting with Vent Damper in Vertical PositionBoiler Removal from Common Venting System Seal any unused openings in the common venting systemGAS Piping Gas Connection to BoilerMIH Boiler Natural Gas Wiring Controls Zoned System WiringElectrical Sequence of Operation Wiring and Connection Diagram Intermittent Ignition Intermittent Ignition System Operating Sequence Zone Wiring with Zone Valves START-UP Procedures Completing the InstallationValve Tapping and Adjustment Screw Locations Operating Instructions For Your Safety Read Before Lighting Adjustment of GAS Pressure Regulator Adjustment of Pilot GAS FlowControl Descriptions CHECK-OUT Procedure Checking Burner InputSTART-UP Procedures Troubleshooting Troubleshooting GuidesProblem Possible Causes Corrective Actions Intermittent Ignition System Troubleshooting Sequence Maintenance Weekly with Boiler in USE GeneralDaily with Boiler in USE Monthly with Boiler in USEAnnually Before Start of Heating Season Standing Pilot and Main Burner FlameBoiler Dimensions & Ratings Series MI/MIH Boiler DimensionsRepair Parts Repair Parts Series MI/MIH GAS Boiler2Manifold Manifold/Gas Train MI Standing Pilot 3b Gas Valve and Pilot Intermittent 4Block/Draft Hood 4a Block/Draft Hood 5Jacket 6Controls/Circulator/Vent Damper Series MI/MIH