Orbit Manufacturing ORBIT-6 RP-206 manual Viewing the Contents of a Location, Hexadecimal Digits

Page 11

Viewing the Contents of a Location

It’s often necessary to check the data stored in a memory location to be sure it’s correct. If improper data is found, it must be corrected in order to obtain the desired system response. The data in a location can either be a number (from 0-9) or a letter (from A-F). Doing so takes advantage of the hexadecimal numbering system. For our purposes, the characters A through F will be referred to as hexadecimal digits.

Whenever the Installer Programming mode is active, the first 4 keypad’s Zone LEDs (1-4) are used to reveal each digit in a selected location. By adding up the values assigned to the lit LEDs, the contents of any location can be determined. See table below.

ZONE LEDs

I.D.:

4

3

2

1

Value:

8

4

2

1

0

off

off

off

off

1

off

off

off

 

ON

2

off

off

ON

off

3

off

off

ON

ON

4

off

ON

off

off

5

off

ON

off

ON

6

off

ON

ON

off

7

off

ON

ON

ON

EXAMPLE: Zone 4-ON Zone 3-off

EXAMPLE: Zone 4-ON Zone 3-off

ZONE LEDs

I.D.:

4

3

2

1

value:

8

4

2

1

 

 

 

 

 

8

ON

off

off

off

9

ON

off

off

ON

A

ON

off

ON

off

B

ON

off

ON

ON

C

ON

ON

off

off

D

ON

ON

off

ON

E

ON

ON

ON

off

F

ON

ON

ON

ON

Zone 2-off Zone 1-ON TOTAL = 9

Zone 2-ON Zone 1-ON TOTAL = B

Hexadecimal Digits

In some locations you may be required to enter hexadecimal digits A - F to do so see the next table.

“A” is entered by pressing [STAY] + [1] “B” is entered by pressing [STAY] + [2] “C” is entered by pressing [STAY] + [3] “D” is entered by pressing [STAY] + [4] “E” is entered by pressing [STAY] + [5] “F” is entered by pressing [STAY] + [6]

Installer Manual

11

Image 11
Contents Installer Manual VER. B Customer Information For service centers please see back cover5IN206IM B Maintenance On/Off Buzzer Silencing an AlarmReset Smoke Detectors Display Troubles Display Memory Setting/ChangingTable of Contents Introduction to the ORBIT-6 Main FeaturesBefore You Begin InstallationMain Panel Technical DataIntroduction to Programming Restoring Factory Defaults to the ORBIT-6Installer Programming KeypadOrbit Programmer Programming your Orbit-6Hexadecimal Digits Viewing the Contents of a LocationProgramming Tutorial Locations Whose Contents Occupy More Than One DigitAudible Tones and Error Beeps How to program installer parametersInstaller Code InstallerMode Access Press 0, 8, ARM Current Installer CodeLocation 01 MS Lock Def Location Default Enable DefGeneral System Parameters Locations System Codes Locations Intrusion Zone Types and Zone Sounds Locations System Time LocationsFire Zone Interior + Entry Delay FollowerKey-switch Zone Instant Key-switch Zone DelayedSpecial Zone Types Location 19 Zone 6 Tamper Zone Utility Outputs LocationsZone 1 Alarm Follow Pulsed Alarm Follow LatchedAlarm Follow Pulse Zone 1 Alarm Follow LatchedVoice Module Enable AUX Power Switch FireLow Battery Follow Latched Low Battery Follow PulseCommunication Parameters Locations Digital Communicator Controls LocationFormat Name Central Station Protocols LocationLocation Dialer Controls 2nd Digit Attempts Location CS Protocols 2 nd Digit Nd Digit Data Rate Understanding the Code FormatLocation CS Protocols 1 st Digit St Digit Format Comments on System Controls Location 30 1st Digit Upload/Download Rings LocationSystem Controls Location Location System Controls 2 nd Digit Nd Digit Silent Panic Bell Squawk on Arming Minute Bypass EnabledComments on System Controls Location 30 2nd Digit Location System Controls 1st Digit St DigitCommunicator Reporting Codes Locations 32 Through Reporting Codes for Alarm EventsLocation Periodic Test Time Default Periodic Test Time LocationTrouble Reports and Restorals Other Reporting CodesLocation Description Entry ORBIT-6 Installer Programming WorksheetCode Program Digit Zones Alarms/DisarmZones Alarms/Disarm Program Digit Code Event Reporting Contact IDTroubles AccessSpecial ORBIT-6 Wiring Diagram ORBIT-6 Wiring Diagram Zone Keypad Board Installer Manual Installer Manual Rokonet Limited Warranty

ORBIT-6 RP-206 specifications

Orbit Manufacturing's ORBIT-6 RP-206 is a state-of-the-art device designed to meet the evolving demands of modern manufacturing processes. Known for its reliability and versatility, the ORBIT-6 RP-206 integrates advanced technologies that enhance operational efficiency and productivity across various industrial applications.

One of the main features of the ORBIT-6 RP-206 is its robust construction, which ensures durability even in the most demanding environments. Built from high-grade materials, this equipment is designed to withstand wear and tear, thus reducing maintenance costs and downtime. The incorporation of a high-performance motor allows for improved power efficiency and faster processing speeds, enabling manufacturers to increase their output without sacrificing quality.

The ORBIT-6 RP-206 utilizes cutting-edge automation technologies. Equipped with a user-friendly interface, it allows for seamless integration into existing manufacturing systems. This system includes programmable features that enable users to customize operations according to their specific requirements. This flexibility makes it an ideal choice for small to medium-sized businesses as well as large-scale manufacturing facilities.

Moreover, one of the standout characteristics of the ORBIT-6 RP-206 is its advanced data analytics capabilities. By leveraging real-time data, manufacturers can continuously monitor performance metrics, allowing for proactive decision-making and process optimization. This feature not only enhances productivity but also contributes to quality control by identifying any deviations or anomalies during production.

Safety is another paramount concern for Orbit Manufacturing. The ORBIT-6 RP-206 incorporates various safety mechanisms, including automatic shut-off systems and emergency stops, ensuring a secure working environment for operators. Additionally, the machine is designed with easy access to key components for maintenance, further reinforcing its commitment to user safety and convenience.

In terms of environmental considerations, the ORBIT-6 RP-206 is engineered to minimize energy consumption and reduce waste. This eco-friendly approach resonates with the growing trend towards sustainable manufacturing practices, ensuring that businesses can meet their environmental goals while maintaining operational efficiency.

In conclusion, Orbit Manufacturing's ORBIT-6 RP-206 stands out as a technologically advanced solution for the modern manufacturing landscape. With its robust construction, automation capabilities, data analytics, safety features, and environmental consciousness, it is poised to deliver exceptional performance, making it an invaluable asset for any manufacturing operation.