Orbit Manufacturing ORBIT-6 RP-206 Special Emergency Keying Follow Latched, User Activated Toggle

Page 21

Special Emergency Keying Follow (Latched)

17UO is activated immediately when pressing the keypad’s [7] and [8] keys simultaneously for two seconds. U0 is deactivated when the system is disarmed.

Special Emergency Keying Follow (Pulsed)

18UO is activated for several seconds when pressing the keypad’s [7] and [8] keys simultaneously for two seconds.

Fire Keying Follow (Latched)

19UO is activated immediately when a Fire alarm is triggered by a violation of zone 5, defined as Fire, or by pressing the keypad’s [4] and [5] keys simultaneously for two seconds. U0 is deactivated when the system is disarmed.

1A

Fire Keying Follow (Pulse)

UO is activated when a Fire alarm is triggered by a violation of zone 5, defined as Fire,

 

or by pressing the keypad’s [4] and [5] keys simultaneously for two seconds.

 

User Activated (Toggle)

 

UO may be activated by the user through the entry of [*]+[2]+[User Code]+[X], where X

1B

refers to the utility output number.

The first entry of the above sequence activates the UO and causes it to latch in the

 

opposite of its current state. The system briefly lights the Zone LED corresponding to the

 

selected UO and produces a single confirming beep subsequent entries toggle the

 

response from ON to OFF to ON, etc.

 

User Activated (Pulse)

 

UO may be activated by the user through the entry of [*]+[2]+[User Code]+[X], where X

1C

refers to the utility output number.

 

The entry activates the UO for several seconds (pulse). The system briefly lights the

 

Zone LED corresponding to the selected UO and produces a single confirming beep

 

subsequent entries repeat this pattern.

 

AUX POWER Switch (Fire)

 

Until triggered, UO is normally activated and is designed to be a part of the circuit

 

supplying power to the Smoke Detector(s); see Figure 1A and 1B.

 

After a Fire Alarm is disarmed, it may be necessary to reset any Smoke Detector(s)

1D

which may be “latched” in alarm. A “latched” Smoke Detector will cause the keyboard’s

FIRE LED to remain lit, even though the panel may be disarmed. To reset a Smoke

 

Detector, a “UO” used in this manner must be momentarily deactivated; this action is

 

performed by the user, who must enter [*]+[2]+[User Code]+[X], where [X] refers to the

 

UO number (i.e. 1,2,3, or 4) in the circuit providing Smoke Detector power. If this is not

 

done, it will be impossible to arm the panel; please advise your customer of this

 

contingency which is stated in the ORBIT-6’s User Manual.

1E

Duress Code Follow (Pulse)

U0 is activated for several seconds (and then deactivates) when any duress code is

 

entered.

1F

AC Loss Follow (Latched)

U0 is activated due to a lack of power from the commercial AC. U0 is deactivated when

 

the system is operating properly from commercial (AC) power.

AC Loss Follow (Pulse)

20U0 is activated for several seconds (and then deactivates) due to a lack of power from the commercial AC.

Low Battery Follow (Latched)

21U0 is activated due to low power from the backup battery. U01 is deactivated when the battery is in good condition.

22Low Battery Follow (Pulse)

U0 is activated for several seconds due to low power from the backup battery.

Voice Module Enable

23The U0 is activated after FM phone number dialing has been made due to alarm. The U0 deactivates after the FM period termination.

Installer Manual

21

Image 21
Contents Installer Manual VER. B Customer Information For service centers please see back cover5IN206IM B Reset Smoke Detectors Silencing an AlarmDisplay Troubles Display Memory Setting/Changing Maintenance On/Off BuzzerTable of Contents Introduction to the ORBIT-6 Main FeaturesBefore You Begin InstallationMain Panel Technical DataInstaller Programming Restoring Factory Defaults to the ORBIT-6Keypad Introduction to ProgrammingOrbit Programmer Programming your Orbit-6Hexadecimal Digits Viewing the Contents of a LocationAudible Tones and Error Beeps Locations Whose Contents Occupy More Than One DigitHow to program installer parameters Programming TutorialMode Access Press 0, 8, ARM InstallerCurrent Installer Code Installer CodeLocation Default Enable Def General System Parameters LocationsLocation 01 MS Lock Def System Codes Locations Intrusion Zone Types and Zone Sounds Locations System Time LocationsKey-switch Zone Instant Interior + Entry Delay FollowerKey-switch Zone Delayed Fire ZoneSpecial Zone Types Location 19 Zone 6 Tamper Zone Utility Outputs LocationsAlarm Follow Pulse Alarm Follow LatchedZone 1 Alarm Follow Latched Zone 1 Alarm Follow PulsedLow Battery Follow Latched AUX Power Switch FireLow Battery Follow Pulse Voice Module EnableCommunication Parameters Locations Digital Communicator Controls LocationCentral Station Protocols Location Location Dialer Controls 2nd Digit AttemptsFormat Name Understanding the Code Format Location CS Protocols 1 st Digit St Digit FormatLocation CS Protocols 2 nd Digit Nd Digit Data Rate Upload/Download Rings Location System Controls LocationComments on System Controls Location 30 1st Digit Comments on System Controls Location 30 2nd Digit Silent Panic Bell Squawk on Arming Minute Bypass EnabledLocation System Controls 1st Digit St Digit Location System Controls 2 nd Digit Nd DigitLocation Periodic Test Time Default Reporting Codes for Alarm EventsPeriodic Test Time Location Communicator Reporting Codes Locations 32 ThroughTrouble Reports and Restorals Other Reporting CodesLocation Description Entry ORBIT-6 Installer Programming WorksheetZones Alarms/Disarm Program Digit Code Zones Alarms/DisarmEvent Reporting Contact ID Code Program DigitAccess SpecialTroubles ORBIT-6 Wiring Diagram ORBIT-6 Wiring Diagram Zone Keypad Board Installer Manual Installer Manual Rokonet Limited Warranty

ORBIT-6 RP-206 specifications

Orbit Manufacturing's ORBIT-6 RP-206 is a state-of-the-art device designed to meet the evolving demands of modern manufacturing processes. Known for its reliability and versatility, the ORBIT-6 RP-206 integrates advanced technologies that enhance operational efficiency and productivity across various industrial applications.

One of the main features of the ORBIT-6 RP-206 is its robust construction, which ensures durability even in the most demanding environments. Built from high-grade materials, this equipment is designed to withstand wear and tear, thus reducing maintenance costs and downtime. The incorporation of a high-performance motor allows for improved power efficiency and faster processing speeds, enabling manufacturers to increase their output without sacrificing quality.

The ORBIT-6 RP-206 utilizes cutting-edge automation technologies. Equipped with a user-friendly interface, it allows for seamless integration into existing manufacturing systems. This system includes programmable features that enable users to customize operations according to their specific requirements. This flexibility makes it an ideal choice for small to medium-sized businesses as well as large-scale manufacturing facilities.

Moreover, one of the standout characteristics of the ORBIT-6 RP-206 is its advanced data analytics capabilities. By leveraging real-time data, manufacturers can continuously monitor performance metrics, allowing for proactive decision-making and process optimization. This feature not only enhances productivity but also contributes to quality control by identifying any deviations or anomalies during production.

Safety is another paramount concern for Orbit Manufacturing. The ORBIT-6 RP-206 incorporates various safety mechanisms, including automatic shut-off systems and emergency stops, ensuring a secure working environment for operators. Additionally, the machine is designed with easy access to key components for maintenance, further reinforcing its commitment to user safety and convenience.

In terms of environmental considerations, the ORBIT-6 RP-206 is engineered to minimize energy consumption and reduce waste. This eco-friendly approach resonates with the growing trend towards sustainable manufacturing practices, ensuring that businesses can meet their environmental goals while maintaining operational efficiency.

In conclusion, Orbit Manufacturing's ORBIT-6 RP-206 stands out as a technologically advanced solution for the modern manufacturing landscape. With its robust construction, automation capabilities, data analytics, safety features, and environmental consciousness, it is poised to deliver exceptional performance, making it an invaluable asset for any manufacturing operation.