Orbit Manufacturing ORBIT-6 RP-206 System Arming, Stay Home Arming, Instant Stay, Zone, User Code

Page 4

Summary of User’s Commands

It is necessary to ARM your system to obtain protection from intrusion.

All other forms of protection, including fire and 24-hour panic alarms (i.e. police, fire, and medical) are always ready to report alarms and do NOT need to be armed.

This page, called a Command Summary, is intended to give you brief summaries of common system operations. More detailed explanations and related information can be found within, by referring to the user manual.

FUNCTION

 

PROCEDURE

 

 

 

 

 

 

System Arming

[USER CODE] + [ARM]

Stay Home Arming

[USER CODE] + [STAY]

Instant Stay

[STAY] + [STAY]

System Disarming

[USER CODE]

Duress Disarming

[DURESS CODE]

Silencing an Alarm

[USER CODE]

Bypassing / Unbypassing a

[ Q ] + [ 1 ] + [USER CODE ] + [ ZONE NUMBER TO BE

Zone

BYPASSED / UNBYPASSED]

Quick Bypassing Zone

[ ZONE NUMBER TO BE BYPASSED ] for at least 2 seconds

Reset Smoke Detector(s)

[ Q ] + [ 2 ] + [USER CODE ] + [UTILITY OUTPUT NUMBER

which is responsible for resetting the Smoke Detector]

 

 

 

Utility Output Operation

[ Q ] + [ 2 ] + [USER CODE ] + [ UTILITY OUTPUT NUMBER ]

Display Troubles

[ Q ] + [ 3 ]

 

 

Display Memory

[ Q ] + [ 4 ]

 

 

Setting/Changing

[ Q] + [ 5 ] + [MASTER CODE] + [CODE NUMBER TO BE

a User Code

SET/CHANGED] + [NEW CODE]

Set Date

[ Q ] + [ 6 ] + [ 1 ] + [MASTER CODE] + [MM] [DD] [YY]

Set Time

[ Q ] + [ 6 ] + [ 2 ] + [MASTER CODE] + [H][H] [M][M]

*Set Auto Arm Time

[ Q ] + [ 6 ] + [ 3 ] + [MASTER CODE] + [H][H] [M][M]

Set Follow-Me Phone No. 1

[ Q ] + [ 7 ] + [ 1 ] + [MASTER CODE] + Phone No. + [ #]

Set Follow-Me Phone No. 2

[ Q ] + [ 7 ] + [ 2 ] + [MASTER CODE] + Phone No. + [ #]

**Set Follow-Me Phone No. 3

[ Q ] + [ 7 ] + [ 3 ] + [MASTER CODE] + Phone No. + [ #]

**Set Follow-Me Phone No. 4

[ Q ] + [ 7 ] + [ 4 ] + [MASTER CODE] + Phone No. + [ #]

Maintenance:

 

 

 

On/Off Buzzer

[ Q ] + [ 8 ] + [MASTER CODE] + [1]

On/Off Door Chime

[ Q ] + [ 8 ] + [MASTER CODE] + [ 2]

*On/Off Audible Kiss-Off

[ Q ] + [ 8 ] + [MASTER CODE] + [ 3]

Indication

 

 

 

Get Event From Event

[ Q ] + [ 9 ] + [MASTER CODE] + [EVENT NO.]

Logger

 

 

 

Test System

[ Q ] + [ 0 ] + [MASTER CODE]

 

 

 

 

 

 

 

 

 

LED

Trouble

 

 

 

 

1

Low Battery

 

 

Trouble Table

 

2

AC Power Loss

 

 

 

3

Clock Not Set

 

 

 

 

 

 

 

 

4

Communication Trouble

 

 

 

 

5

Bell Loop Trouble

 

*New in Version 1.2

 

 

 

**New in Version 1.3

 

 

 

4

Installer Manual

Image 4 Contents
Installer Manual VER. B For service centers please see back cover Customer Information5IN206IM B Silencing an Alarm Reset Smoke DetectorsDisplay Troubles Display Memory Setting/Changing Maintenance On/Off BuzzerTable of Contents Main Features Introduction to the ORBIT-6Installation Before You BeginTechnical Data Main PanelRestoring Factory Defaults to the ORBIT-6 Installer ProgrammingKeypad Introduction to ProgrammingProgramming your Orbit-6 Orbit ProgrammerViewing the Contents of a Location Hexadecimal DigitsLocations Whose Contents Occupy More Than One Digit Audible Tones and Error BeepsHow to program installer parameters Programming TutorialInstaller Mode Access Press 0, 8, ARMCurrent Installer Code Installer CodeGeneral System Parameters Locations Location Default Enable DefLocation 01 MS Lock Def System Codes Locations System Time Locations Intrusion Zone Types and Zone Sounds LocationsInterior + Entry Delay Follower Key-switch Zone InstantKey-switch Zone Delayed Fire ZoneSpecial Zone Types Utility Outputs Locations Location 19 Zone 6 Tamper ZoneAlarm Follow Latched Alarm Follow PulseZone 1 Alarm Follow Latched Zone 1 Alarm Follow PulsedAUX Power Switch Fire Low Battery Follow LatchedLow Battery Follow Pulse Voice Module EnableDigital Communicator Controls Location Communication Parameters LocationsLocation Dialer Controls 2nd Digit Attempts Central Station Protocols LocationFormat Name Location CS Protocols 1 st Digit St Digit Format Understanding the Code FormatLocation CS Protocols 2 nd Digit Nd Digit Data Rate System Controls Location Upload/Download Rings LocationComments on System Controls Location 30 1st Digit Silent Panic Bell Squawk on Arming Minute Bypass Enabled Comments on System Controls Location 30 2nd DigitLocation System Controls 1st Digit St Digit Location System Controls 2 nd Digit Nd DigitReporting Codes for Alarm Events Location Periodic Test Time DefaultPeriodic Test Time Location Communicator Reporting Codes Locations 32 ThroughOther Reporting Codes Trouble Reports and RestoralsORBIT-6 Installer Programming Worksheet Location Description EntryZones Alarms/Disarm Zones Alarms/Disarm Program Digit CodeEvent Reporting Contact ID Code Program DigitSpecial AccessTroubles ORBIT-6 Wiring Diagram ORBIT-6 Wiring Diagram Zone Keypad Board Installer Manual Installer Manual Rokonet Limited Warranty