Orbit Manufacturing ORBIT-6 RP-206 manual Upload/Download Rings Location, System Controls Location

Page 25

Location: 28

CS Protocols:

When selecting a contact ID & SIA format, all the reporting codes will be automatically applied to the locations of the reporting codes.

To change a code, enter a new code (according to the type of event – see page 30) to the corresponding location.

When selecting the Pulsed Protocol the default for all the reported codes will be “00” and any other code should be entered manually

To remove a particular reporting code from any of the 3 Protocols enter “00” into the corresponding location.

Important: Choose the code format only after defining the zone parameters. Changing a zone type after selecting the code format WILL NOT change the zone’s reporting code and a faulty report will be sent to the central station.

Digit

Format Name

Interdigit Time

Data Frequency

00

Pulsed Protocol

 

 

01

Contact ID

NA

NA

02

SIA

390 ms

1800 Hz

**03

Ademco 4/2 Express

 

 

(Ver. 1.3)

 

 

Upload/Download Rings: Location 29

Location 29 sets the number of rings that the ORBIT-6 will wait before automatically answering an incoming call. If such a call was initiated by the alarm company’s Upload/Download software, a process begins which allows a Remote Programming session to take place.

Location: 29

Number of Rings

Default: 12

Choose a number of rings greater than that which the customer will normally wait to answer

an incoming call enter two digits; (between 00-15 rings)

Number

Note: if an Answering Machine is in use and so programmed

of Rings

(see Location 26 / 2nd Digit), entries made in this location will be ignored

 

 

SYSTEM CONTROLS: LOCATION 30

Location 30 allows you to specify some additional parameters, which determine how the ORBIT-6 will operate. The location contains two digits.

First digit: determine the number (or letter) corresponding to the choices involving Quick Arm / Quick Bypass / UO Extender / Loudspeaker / Bell-Siren

Second digit: determine the number (or letter) corresponding to the use of Silent Panic / Bell Squawk on Arming / 3 Minute Bypass

Comments on System Controls (Location 30: 1st Digit)

Quick Arm

Quick Bypass

UO Extender

Loudspeaker/Bell-Siren

 

 

 

 

Quick Arm

Eliminates the

select UO Extender

select Loudspeaker if the

eliminates the

need to enter a

if the Utility Output

external sounder(s) is NOT

need for entering

User Code when

Expansion Module is

equipped with a built-in sound

a User Code when

bypassing a zone.

installed

driver; doing so causes the

arming to the STAY

 

 

ORBIT-6 to produce an

or AWAY modes.

 

 

oscillating frequency for the

simply pressing

 

 

device, select Bell/Siren if the

[STAY] or [ARM] will

 

 

external sounder(s) is a bell or

arm the system to

 

 

a buzzer or equipped with a

the respective mode

 

 

built-in electronic sound driver;.

Installer Manual

25

 

Image 25
Contents Installer Manual VER. B Customer Information For service centers please see back cover5IN206IM B Reset Smoke Detectors Silencing an AlarmDisplay Troubles Display Memory Setting/Changing Maintenance On/Off BuzzerTable of Contents Introduction to the ORBIT-6 Main FeaturesBefore You Begin InstallationMain Panel Technical DataInstaller Programming Restoring Factory Defaults to the ORBIT-6Keypad Introduction to ProgrammingOrbit Programmer Programming your Orbit-6Hexadecimal Digits Viewing the Contents of a LocationAudible Tones and Error Beeps Locations Whose Contents Occupy More Than One DigitHow to program installer parameters Programming TutorialMode Access Press 0, 8, ARM InstallerCurrent Installer Code Installer CodeGeneral System Parameters Locations Location Default Enable DefLocation 01 MS Lock Def System Codes Locations Intrusion Zone Types and Zone Sounds Locations System Time LocationsKey-switch Zone Instant Interior + Entry Delay FollowerKey-switch Zone Delayed Fire ZoneSpecial Zone Types Location 19 Zone 6 Tamper Zone Utility Outputs LocationsAlarm Follow Pulse Alarm Follow LatchedZone 1 Alarm Follow Latched Zone 1 Alarm Follow PulsedLow Battery Follow Latched AUX Power Switch FireLow Battery Follow Pulse Voice Module EnableCommunication Parameters Locations Digital Communicator Controls LocationLocation Dialer Controls 2nd Digit Attempts Central Station Protocols LocationFormat Name Location CS Protocols 1 st Digit St Digit Format Understanding the Code FormatLocation CS Protocols 2 nd Digit Nd Digit Data Rate System Controls Location Upload/Download Rings LocationComments on System Controls Location 30 1st Digit Comments on System Controls Location 30 2nd Digit Silent Panic Bell Squawk on Arming Minute Bypass EnabledLocation System Controls 1st Digit St Digit Location System Controls 2 nd Digit Nd DigitLocation Periodic Test Time Default Reporting Codes for Alarm EventsPeriodic Test Time Location Communicator Reporting Codes Locations 32 ThroughTrouble Reports and Restorals Other Reporting CodesLocation Description Entry ORBIT-6 Installer Programming WorksheetZones Alarms/Disarm Program Digit Code Zones Alarms/DisarmEvent Reporting Contact ID Code Program DigitSpecial AccessTroubles ORBIT-6 Wiring Diagram ORBIT-6 Wiring Diagram Zone Keypad Board Installer Manual Installer Manual Rokonet Limited Warranty

ORBIT-6 RP-206 specifications

Orbit Manufacturing's ORBIT-6 RP-206 is a state-of-the-art device designed to meet the evolving demands of modern manufacturing processes. Known for its reliability and versatility, the ORBIT-6 RP-206 integrates advanced technologies that enhance operational efficiency and productivity across various industrial applications.

One of the main features of the ORBIT-6 RP-206 is its robust construction, which ensures durability even in the most demanding environments. Built from high-grade materials, this equipment is designed to withstand wear and tear, thus reducing maintenance costs and downtime. The incorporation of a high-performance motor allows for improved power efficiency and faster processing speeds, enabling manufacturers to increase their output without sacrificing quality.

The ORBIT-6 RP-206 utilizes cutting-edge automation technologies. Equipped with a user-friendly interface, it allows for seamless integration into existing manufacturing systems. This system includes programmable features that enable users to customize operations according to their specific requirements. This flexibility makes it an ideal choice for small to medium-sized businesses as well as large-scale manufacturing facilities.

Moreover, one of the standout characteristics of the ORBIT-6 RP-206 is its advanced data analytics capabilities. By leveraging real-time data, manufacturers can continuously monitor performance metrics, allowing for proactive decision-making and process optimization. This feature not only enhances productivity but also contributes to quality control by identifying any deviations or anomalies during production.

Safety is another paramount concern for Orbit Manufacturing. The ORBIT-6 RP-206 incorporates various safety mechanisms, including automatic shut-off systems and emergency stops, ensuring a secure working environment for operators. Additionally, the machine is designed with easy access to key components for maintenance, further reinforcing its commitment to user safety and convenience.

In terms of environmental considerations, the ORBIT-6 RP-206 is engineered to minimize energy consumption and reduce waste. This eco-friendly approach resonates with the growing trend towards sustainable manufacturing practices, ensuring that businesses can meet their environmental goals while maintaining operational efficiency.

In conclusion, Orbit Manufacturing's ORBIT-6 RP-206 stands out as a technologically advanced solution for the modern manufacturing landscape. With its robust construction, automation capabilities, data analytics, safety features, and environmental consciousness, it is poised to deliver exceptional performance, making it an invaluable asset for any manufacturing operation.