Ciprico 6500 manual Step Configure Array, Step Power Up Host System, Drive Status Codes

Page 29

Chapter 2 Installation

Installation Procedure

Page 2 - 5

Drive Status Codes

The following codes on the display/operation panel indicate drive status:

Code

Drive Status

O

OFF

 

 

S

Spinning

 

 

G

Good (Tested OK)

 

 

T

Testing

 

 

R

Ready

 

 

U

Unformatted for Array

 

 

X

Out of Order

 

 

?

Unknown Status

 

 

F

Failed

 

 

Table 1: Drive Status Codes

At array reset or power-up, a Built-In Self-Test (BIST) will run. During BIST, the drive status display reflects the test stage that each drive is passing through. Under normal conditions, each drive passes through stages OFF, Spinning, Testing, Good, and then Ready, as listed above.

When all drives are in the same state, an English-language status message will appear on the display/operation panel.

During the spin-up process, all drives in the a rray reach their normal operating speed and each drive is tested. When testing and spin-up are complete, the 67$786￿2.message appears.

Step 9.

Configure the

Array

Ciprico ships 6500 arrays with default settings designed to suit most operating environments. If necessary, you may reconfigure the array using the display/ operation panel. (Chapter 3 in this guide describes how you can use the display/ operation panel to verify or change the array’s operating parameters.)

In most situations, you will only have to reconfigure two parameters:

Array SCSI ID—Each device on the SCSI bus must have a unique ID.

UNIT ATTENTION reporting—SCSI drivers in some systems do not handle this parameter correctly and it may have to be disabled.

Step 10.

Power Up the

Host System

When the 6500 array has been properly configured, power up the host computer.

6500 Disk Array User’s Guide

21020690 B

Image 29
Contents Ciprico Disk Array Page Page Chapter Programmer Reference Notational Conventions PrefaceThis Guide Revision History Fire Shock Hazards Power CordUnited States Electro- magnetic CompatibilitySafety Listings Certification Contents Array Options ON/OFF Line Scsi ID Password LOG Pages Error Counters Removal Table of Contents Table of Contents 21020690 B Disk Array User’s Guide S c r i p t i o n Ciprico 6500 Disk Array 21020690 B Disk Array User’s Guide This ChapterDisk Array Functions Application Parity Drive Features and OptionsScsi Compatibility Enclosure Enclosure Air Filter Controller Board Primary ComponentsPrimary Components Disk Array User’s Guide 21020690 B Select Switch Reset SwitchNavigation Switches Up, Down, Left, Right DisplayScsi Connectors Activity LED Rear Panel Switches ConnectorsPage Installation Installation Step Attach Scsi Cable Terminate Scsi Bus, if Necessary Installation ProcedureMove Array to Operation Site Step Mount Enclosure Drive Status Drive Status Codes Step Configure ArrayStep Power Up Host System Page S p l a y / O p e r a t i o n P a n e l Change operating parameters, and manually control the array 6500 Display/Operation Panel Controls and IndicatorsOperation Guidelines Array Power Up and Built-In Self-TestBist Initial DisplayChanging or Selecting a Menu Option Saving Changes Default SettingsMenu Option Descriptions Chapter Display/Operation Panel Operation Guidelines Display/Operation Panel Operation Guidelines Chapter Display/Operation Panel Operation Guidelines Display/Operation Panel Operation Guidelines Chapter Display/Operation Panel Operation Guidelines Scsi ID ON/OFF LineEnter a new password as follows Press the down arrow Enter a New PasswordClear Password AlarmUnit Attention WriteRecover DefaultsSET RPT AS1250$7,21 Info CapacityInitiator MEGoMETER Display Rebuild Data REBUILD% RebuildSector Size Data Fill Start FormatStatus Disable DriveDrive Drive n REV Drive InfoDrive n Model Entry k / Drive n DRV n ERR Count / RecoveredDRV n ERR Count / Medium Drive Failures Reset LOG Enable LOGRecovered / wwwww Errs Recovered / vvvvv ErrsPage Maintenance, Troubleshooting & Hardware Replacement Checking Enclosure Cooling Fan Operation Power Supply Periodic Maintenance GuidelinesCleaning Enclosure Air Filter Failure Detection and Troubleshoot- ing Guidelines Error/Failure Messages Failure IndicatorsAudible Alarm Built-In Self Test Bist Failures IndicatorsIf%86,6+/ you$,7,1* see this HandlingDrive Test Failures Disk Drive Failures 21/,15555 If you555 see this5Array Temperature Over- temperature FailuresTroubleshoot- ing Guidelines Hardware Field Replaceable Units FRUs Field Replacement Guidelines Location FRUs ArrayPage Top Cover Removal 21020690 B Disk Array User’s Guide Enclosure Top Cover RemovalController Board Removal Display Operation Panel Removal Power Supply Removal Power Supply Removal-Mechanical Disconnection Cooling Fan Removal Cooling Fan Removal/ReplacementPower Switch Removal Reporting Drive Failure Drive Failure Replacement RebuildingDetermining Drive Failure Indications To Turn Off Alarm, Press Select KeyDrive Failure Disabling a Failed Disk Drive Disk Drive Removal Disk Drive ReplacementDrive Setup Requirements Types of Rebuilds Initiating a Rebuild MenuError Code Meanings Drive Error Code During RebuildPress the up arrow.6 Formatting the ArrayArray Formatting Message Definitions Formatting Error Code CorrectReplacing EEPROMs Updating FirmwareDisk Array User’s Guide 21020690 B Page Numerics Index Scsi SCSI-P Page 21020690 B