| Chapter 3 Display/Operation Panel |
Page 3 - 24 | LOG PAGES | |
|
| 2)) 21 |
ENABLE LOG | This item lets you enable or disable the logging function by choosing or | |
|
| . The factory default setting is 21. If you cycle power, the (1$%/(/2* |
|
| item will come up in the condition it was in when you turned off the array. |
RESET LOG | This command sets all log counters back to zero and sets functions to their | |
|
| default conditions. When you invoke this command, all entries for drive errors |
|
| and drive failures will be erased. The default setting is 12. To implement this |
|
| command, use the left arrow key to select <(6, then press SELECT. After a |
|
| reset, this parameter reverts to 12. |
SET THRESHOLDS
This item allows you to view and set thresholds for the number of errors at which the array will automatically shut down a drive. There are separate thresholds for recovered errors and medium errors, but each of these thresholds applies to all nine drives. Factory defaults for both recovered and medium errors are zero, which indicates that the
SET THRESHOLDS / RECOVERD
Gives access to view and set the threshold for triggering of automatic shutdowns because of recovered errors.
RECOVERED / wwwww ERRS
To set the threshold for recovered errors, press the down arrow. This causes the cursor to flash over the least significant digit of the
SET THRESHOLDS / MEDIUM
Gives access to view and set the threshold for triggering of automatic shutdowns because of
RECOVERED / vvvvv ERRS
To set the threshold for medium errors, press the down arrow. This causes the cursor to flash over the least significant digit of the
21020690 B | 6500 Disk Array User’s Guide |