Ciprico 6500 manual Features and Options, Scsi Compatibility, Parity Drive

Page 18

Chapter 1 Description

Page 1 - 4

 

Features and Options

Features and Options

SCSI Compatibility

Conforms to SCSI-2 standards.

8- or 16-bit data transfers on host inte rface.

Single-ended or differential SCSI interface.

Compatible with industry-standard SCSI adapters and drivers, including all Ciprico SCSI host bus adapters.

Controller Board

Disk Drives

Redundancy

Parallel Disk

Array

Architecture

SCSI-2 to ATA RAID-3 disk array controller with a 16-bit host SCSI interface and 9 ATA interfaces.

9 ATA disk drives (8 data, one parity).

Continued operation after failure of a single data drive.

Ciprico’s 6500 parallel disk array communicates with an initiator (or host) via the SCSI-2 industry standard interface. The array’s design combines current drive technology with an advanced controller board, where data is “striped” across eight drives at once. Byte-striping involves partitioning of data into bytes, with each byte assigned to a particular drive and all bytes written to the drives simultaneously. Using this method, transfer rates for read/write functions are significantly faster than a single disk drive having the same capacity.

Parity Drive

Improved reliability and data availability are provided by a dedicated parity

 

drive. As data is striped to the eight data drives, parity data is generated and

 

stored on the parity drive. Parity information is used to verify data integrity

 

when reading from the drives, and to regenerate data if a drive should fail and

 

is replaced. A single drive failure will not degrade overall performance. Use of

21020690 B

6500 Disk Array User’s Guide

Image 18
Contents Ciprico Disk Array Page Page Chapter Programmer Reference Preface This GuideNotational Conventions Power Cord Revision History Fire Shock HazardsElectro- magnetic Compatibility United StatesSafety Listings Certification Contents Array Options ON/OFF Line Scsi ID Password LOG Pages Error Counters Removal Table of Contents Table of Contents 21020690 B Disk Array User’s Guide S c r i p t i o n This Chapter Ciprico 6500 Disk Array 21020690 B Disk Array User’s GuideDisk Array Functions Application Features and Options Scsi CompatibilityParity Drive Enclosure Primary Components Enclosure Air Filter Controller BoardPrimary Components Disk Array User’s Guide 21020690 B Navigation Switches Up, Down, Left, Right Reset SwitchSelect Switch DisplayRear Panel Switches Connectors Scsi Connectors Activity LEDPage Installation Installation Installation Procedure Move Array to Operation Site Step Mount EnclosureStep Attach Scsi Cable Terminate Scsi Bus, if Necessary Drive Status Step Configure Array Step Power Up Host SystemDrive Status Codes Page S p l a y / O p e r a t i o n P a n e l Change operating parameters, and manually control the array Controls and Indicators 6500 Display/Operation PanelBist Array Power Up and Built-In Self-TestOperation Guidelines Initial DisplayDefault Settings Menu Option DescriptionsChanging or Selecting a Menu Option Saving Changes Chapter Display/Operation Panel Operation Guidelines Display/Operation Panel Operation Guidelines Chapter Display/Operation Panel Operation Guidelines Display/Operation Panel Operation Guidelines Chapter Display/Operation Panel Operation Guidelines ON/OFF Line Scsi IDEnter a New Password Enter a new password as follows Press the down arrowUnit Attention AlarmClear Password WriteSET DefaultsRecover RPT AS1250$7,21 Capacity InitiatorInfo MEGoMETER Display Rebuild Rebuild Data REBUILD%Format Sector Size Data Fill StartDisable Drive DriveStatus Drive Info Drive n ModelDrive n REV DRV n ERR Count / Recovered DRV n ERR Count / MediumEntry k / Drive n Drive Failures Recovered / wwwww Errs Enable LOGReset LOG Recovered / vvvvv ErrsPage Maintenance, Troubleshooting & Hardware Replacement Periodic Maintenance Guidelines Checking Enclosure Cooling Fan Operation Power SupplyCleaning Enclosure Air Filter Failure Detection and Troubleshoot- ing Guidelines Failure Indicators Audible AlarmError/Failure Messages Indicators Built-In Self Test Bist FailuresHandling If%86,6+/ you$,7,1* see this21/,15555 If you555 see this5 Drive Test Failures Disk Drive FailuresOver- temperature Failures Array TemperatureTroubleshoot- ing Guidelines Field Replacement Guidelines Location FRUs Array Hardware Field Replaceable Units FRUsPage Enclosure Top Cover Removal Top Cover Removal 21020690 B Disk Array User’s GuideController Board Removal Display Operation Panel Removal Power Supply Removal Power Supply Removal-Mechanical Disconnection Cooling Fan Removal/Replacement Cooling Fan RemovalPower Switch Removal Drive Failure Replacement Rebuilding Determining Drive FailureReporting Drive Failure To Turn Off Alarm, Press Select Key Drive FailureIndications Disabling a Failed Disk Drive Disk Drive Replacement Drive Setup RequirementsDisk Drive Removal Types of Rebuilds Menu Initiating a RebuildDrive Error Code During Rebuild Error Code MeaningsFormatting the Array Press the up arrow.6Formatting Error Code Correct Array Formatting Message DefinitionsUpdating Firmware Replacing EEPROMsDisk Array User’s Guide 21020690 B Page Numerics Index Scsi SCSI-P Page 21020690 B