Page 3 - 18
REBUILD
REBUILD
DATA
REBUILD%
page
From5(%8,/')81&7,216(/(&75(%8,/'use the left/right arrow keys to select the following functions (see “Menu Structure (3 of
Caution If a disk in the array fails, replace the drive and perform a rebuild as soon as possible. A rebuild can be performed without taking the array
Your selection for the'$7$parameter determines whether or not the data from the failed drive will be reconstructed on the new replacement disk drive. 21means the data will be rebuilt; 2))means the data will not be rebuilt.
Caution '$7$21should always be selected for a data rebuild. Rebuilding with this selection 2))may result in data corruption and/or inter- drive parity errors.
This menu selection allows you to select the percentage of processing time the array will dedicate to the rebuilding process: , or . The lower the percentage, the longer the rebuild will take. The default setting is .
START This selection must be set to <(6before you press SELECT to rebuild a drive.
21020690 B | 6500 Disk Array User’s Guide |