Ciprico 6500 manual Capacity, Initiator, Info

Page 46

 

 

Chapter 3 Display/Operation Panel

Page 3 - 16

 

ARRAY INFORMATION

CAPACITY

Displays the logical block number of the last data block in the array. A value

 

 

followed by 'indicates a decimal number; a value followed by +indicates a

 

 

hex number.

 

 

To calculate the capacity of the array, add one to the number displayed. For

 

 

example, a display with ￿￿￿￿￿￿￿'in an array formatted with 512 as the

 

 

sector size indicates that the array's capacity is 4,207,837 blocks of 512 bytes

 

 

each.

INITIATOR

A SCSI-2 bus can have up to 16 devices attached to it, with some devices acting

 

INFO

as initiators of SCSI commands, and some acting as targets. The array is always

 

 

a target.

 

 

The SCSI protocol allows targets and initiators to negotiate the width of the

 

 

bus to be used when transferring data, the transfer rate, and also whether the

 

 

transfer will be synchronous or asynchronous. This information is stored by the

 

 

array for each initiator on the SCSI bus under Array Information.

P is the Transfer Period

O is the Synchronous Offset

W indicates that a wide 16-bit bus will be used

N indicates that a narrow 8-bit bus will be used

To determine the Transfer Rate from the Transfer Period:

1.Translate the hexadecimal Transfer Period into decimal. For example, 19H equals decimal 25.

2.Multiply the decimal value by 4 to get the Transfer Period in nanoseconds (25 x 4 = 100).

3.Take the reciprocal of this value to get the Transfer Rate in Megahertz (1/100-9= 10 Megahertz).

4.Multiply by the bus width (1 or 2 bytes) to get the bus burst transfer rate, e.g., 10 MHz x 2 bytes wide = 20MB/second.

Note Because the 6510 employs Wide Ultra SCSI technology, the SCSI specification requires a slight variation to the computations above. Wide Ultra SCSI technology is designated as 0CH or decimal 12, when in fact it is slightly longer at 12.5. When the designated period is multiplied by 4 to get the Transfer Period in nanoseconds, the result is 48. In reality it is 50, which is the value whose reciprocal 1/50 nanoseconds equals 20 Megahertz (20MB/ second).

21020690 B

6500 Disk Array User’s Guide

Image 46
Contents Ciprico Disk Array Page Page Chapter Programmer Reference This Guide PrefaceNotational Conventions Power Cord Revision History Fire Shock HazardsElectro- magnetic Compatibility United StatesSafety Listings Certification Contents Array Options ON/OFF Line Scsi ID Password LOG Pages Error Counters Removal Table of Contents Table of Contents 21020690 B Disk Array User’s Guide S c r i p t i o n This Chapter Ciprico 6500 Disk Array 21020690 B Disk Array User’s GuideDisk Array Functions Application Scsi Compatibility Features and OptionsParity Drive Enclosure Primary Components Enclosure Air Filter Controller BoardPrimary Components Disk Array User’s Guide 21020690 B Navigation Switches Up, Down, Left, Right Reset SwitchSelect Switch DisplayRear Panel Switches Connectors Scsi Connectors Activity LEDPage Installation Installation Move Array to Operation Site Step Mount Enclosure Installation ProcedureStep Attach Scsi Cable Terminate Scsi Bus, if Necessary Drive Status Step Power Up Host System Step Configure ArrayDrive Status Codes Page S p l a y / O p e r a t i o n P a n e l Change operating parameters, and manually control the array Controls and Indicators 6500 Display/Operation PanelBist Array Power Up and Built-In Self-TestOperation Guidelines Initial DisplayMenu Option Descriptions Default SettingsChanging or Selecting a Menu Option Saving Changes Chapter Display/Operation Panel Operation Guidelines Display/Operation Panel Operation Guidelines Chapter Display/Operation Panel Operation Guidelines Display/Operation Panel Operation Guidelines Chapter Display/Operation Panel Operation Guidelines ON/OFF Line Scsi IDEnter a New Password Enter a new password as follows Press the down arrowUnit Attention AlarmClear Password WriteSET DefaultsRecover RPT AS1250$7,21 Initiator CapacityInfo MEGoMETER Display Rebuild Rebuild Data REBUILD%Format Sector Size Data Fill StartDrive Disable DriveStatus Drive n Model Drive InfoDrive n REV DRV n ERR Count / Medium DRV n ERR Count / RecoveredEntry k / Drive n Drive Failures Recovered / wwwww Errs Enable LOGReset LOG Recovered / vvvvv ErrsPage Maintenance, Troubleshooting & Hardware Replacement Periodic Maintenance Guidelines Checking Enclosure Cooling Fan Operation Power SupplyCleaning Enclosure Air Filter Failure Detection and Troubleshoot- ing Guidelines Audible Alarm Failure IndicatorsError/Failure Messages Indicators Built-In Self Test Bist FailuresHandling If%86,6+/ you$,7,1* see this21/,15555 If you555 see this5 Drive Test Failures Disk Drive FailuresOver- temperature Failures Array TemperatureTroubleshoot- ing Guidelines Field Replacement Guidelines Location FRUs Array Hardware Field Replaceable Units FRUsPage Enclosure Top Cover Removal Top Cover Removal 21020690 B Disk Array User’s GuideController Board Removal Display Operation Panel Removal Power Supply Removal Power Supply Removal-Mechanical Disconnection Cooling Fan Removal/Replacement Cooling Fan RemovalPower Switch Removal Determining Drive Failure Drive Failure Replacement RebuildingReporting Drive Failure Drive Failure To Turn Off Alarm, Press Select KeyIndications Disabling a Failed Disk Drive Drive Setup Requirements Disk Drive ReplacementDisk Drive Removal Types of Rebuilds Menu Initiating a RebuildDrive Error Code During Rebuild Error Code MeaningsFormatting the Array Press the up arrow.6Formatting Error Code Correct Array Formatting Message DefinitionsUpdating Firmware Replacing EEPROMsDisk Array User’s Guide 21020690 B Page Numerics Index Scsi SCSI-P Page 21020690 B