Agilent Technologies 6843A Scrolling Keys, Meter Display Keys, Display Measurement, KBESSEL, Rect

Page 35

Front Panel Operation - 4

Scrolling Keys

 

 

ScrollingÅ Ùkeys let you move through the commands in the presently selected function menu.

These scroll keys let you move through the choices in a command list.

Press q

to bring up the next command in the list. Press p

to go back

to the previous command in the list. Function menus are circular; you can return to the starting position by continuously pressing either key. The following example shows the commands in the Input function menu:

Shift

 

pIndex

 

 

 

 

 

Shift

 

qIndex

 

 

 

°

These shifted scroll keys apply only to the Harmonic and List functions. Press these keys to step through integers 0 through 50 when specifying the desired harmonic number, or 0 through 99 when specifying the desired list point. Hold down these keys to rapidly access any harmonic or list point.

These Entry keys let you scroll through choices in a parameter list that apply to a specific command. Parameter lists are circular; you can return to the starting position by continuously pressing either key. If the command has a numeric range, these keys increment or decrement the existing value.

Meter Display Keys

Metering keys control the metering functions of the ac source.

Meter

Press this key to access the meter menu list.

Display

Measurement

<reading>V <reading>Hz

rms voltage and frequency (the default)

<reading>V <reading>A

rms voltage and rms current

<reading>A <reading>Hz

rms current and frequency (the default)

<reading>V <reading>W

rms voltage and power

<reading> CREST F

current crest factor

<reading>A PK REP

peak current, repetitive

<reading>A PK NR

peak current, nonrepetitive1

<reading> VA

apparent power

<reading> VAR

reactive power

<reading>W TOTAL

total power of all phases2

<reading> PFACTOR

power factor

<reading>A NEUTRAL

neutral rms current2

Input

Press this key to specify the following metering functions.

Display

Command Function

INP:COUP <char>

Choose meter coupling (AC, DC or ACDC)

WINDOW <char>

Select harmonic measurement window meter

 

(KBESSEL, RECT)

Notes:

1Displays the highest peak current since it was last cleared. The value is cleared when you scroll intoq￿this selection or press Enter or Clear Entry

2This selection only valid for Agilent 6834B reading = the returned measurement

char = a character string parameter

and scroll through the command list.

and scroll through the parameter list.

35

Image 35
Contents User’s Guide AC Power Solutions Agilent Models 6814B, 6834B, and 6843ACertification Warranty InformationGeneral Safety SummarySafety Symbols EMC DeclarationPrinting History Acoustic Noise InformationTable of Contents Entry Keys Examples of Front Panel Programming Specifications Supplemental CharacteristicsPerforming the Calibration Procedure Error Number ListLocation Document OrientationTopic Agilent Part Number Safety ConsiderationsOptions, Accessories, and User Replaceable Parts Option DescriptionModel Description DescriptionCapabilities Ranges Output CharacteristicFront Panel/Remote Operation Output VA Capability AC Source Output Characteristic in real-time modePage Items Supplied CleaningInspection Damage Packaging MaterialNot block the fan exhaust at the rear of the unit LocationBench Operation Rack MountingInput Source and Line Fuse Installing the Power CordInput Connections Output Connections Output ConnectionsAmpacity and Resistance of Stranded Copper Conductors Wire ConsiderationsVoltage Drops Current RatingsRemote Sense Connections Remote Sense ConnectionsOutput Rating Trigger ConnectionsDigital Connections OVP ConsiderationsController Connections Gpib ConnectorRS-232 Data Format Interface CommandsRS-232 Connector RS-232 InterfaceNull Modem Interface Lines Response Data Terminator Hardware HandshakePreliminary Checkout IntroductionCheckout Procedure Using the KeypadProtclear Procedure Display ExplanationVolt Currprot OFF VoltprotCurrlev CurrprotLine Fuse Error MessagesCase of Trouble Page Front Panel, Overall View Front Panel DescriptionAC+DC System Keys Display Command FunctionImmediate Action Keys Annunciator On Phase SelectedFunction Keys KBESSEL, Rect Scrolling KeysMeter Display Keys Display MeasurementDisplay Output Control KeysRST CLS Protection and Status Control KeysAbort Trigger and List Control KeysInitimmed IMMThrough Are used for entering numeric values Is the decimal Entry KeysSet the output to 120 V rms as follows Setting the Output Voltage AmplitudeProcedure for Single-Phase AC Sources Examples of Front Panel ProgrammingTo verify the output, you can measure it as follows Procedure for Three-Phase AC SourcesPhase 3 to 235 Vrms Action DisplayOvercurrent protection feature as follows Setting the Output FrequencySetting a Protection Feature Voltm Step Using Transient Voltage ModesStep Transient VolttDcycle Pulse TransientVoltm Pulse WidthVoltm Fixed Voltm List Count List TransientAction Volt EOL Step Auto Trigger Delays and Phase SynchronizationSyncphas Initimmed Syncsour PhaseExample Display Example Voltm Step Syncsour Phase Syncphas InitimmedProgramming Slew Rates Using Slew Rates to Generate WaveformsSlewt Voltm FixedSlew Step SlewmCurrpeak Syncsour Phase SyncphasMeasuring Peak Inrush Current RangeAction Display To set the Gpib address, proceed as follows Setting the Gpib Address and RS-232 ParametersTo configure the RS-232 interface, proceed as follows Saving and Recalling Operating StatesAddress Noutputs Agilent 6814B Agilent 6834B Agilent 6843A SpecificationsTable A-1. Performance Specifications1 Table A-2. Supplemental Characteristics Supplemental CharacteristicsSpecifications a Page Recommended Model CharacteristicsEquipment Required Performing the Verification Tests Test SetupTurn-On Checkout Procedure Action Normal Result Voltage Programming and Measurement AccuracyRMS Current Readback Accuracy Agilent 6843A Current Measurement Accuracy Performing the Calibration ProcedureAgilent 6814B Current Measurement Accuracy Agilent 6834B Current Measurement AccuracyFront Panel Calibration Menu Enable Calibration ModeFront Panel Calibration Calibrating the OVP trip point Calibrating and Entering Voltage Calibration ValuesCalibrating and Entering Current Calibration Values Calpass Changing the Calibration PasswordCalibrating the Output Impedance Agilent 6843A only Saving the Calibration ConstantsAgilent Calibration Program Listing Calibration Error MessagesTable B-3. Gpib Calibration Error Messages Calibration Over the GpibFigure B-2. Calibration Program Listing Sheet 1 Figure B-2. Calibration Program Listing Sheet 2 Page Table C-1. Error Numbers Error Number ListError Messages Error Messages C Page Index Index Index Japan United States Latin AmericaCanada Australia/New Zealand Europe Asia PacificManual Updates
Related manuals
Manual 20 pages 27.01 Kb Manual 187 pages 38.86 Kb

6834B, 6843A, 6814B specifications

Agilent Technologies, a leader in electronic test and measurement equipment, offers a range of powerful signal sources including the 6843A, 6834B, 6814B, 6813B, and 6811B models. These instruments are designed to support various applications in research, development, and manufacturing, providing precise signal generation capabilities.

The Agilent 6843A is a versatile signal generator known for its exceptional frequency range and modulation capabilities. It supports an extensive bandwidth, making it ideal for applications that require high-frequency signal generation. With its superior phase noise performance, the 6843A is an excellent choice for radar, wireless communications, and electronic warfare applications. The instrument features an intuitive user interface, allowing engineers to set parameters quickly and efficiently.

Next, the Agilent 6834B offers exceptional performance characteristics, including high output power and low distortion. This signal generator is particularly noted for its ability to produce complex modulation formats, making it suitable for testing advanced wireless communication systems. With a reliable and stable output, the 6834B ensures accurate and repeatable measurements, which is vital for thorough testing processes.

The 6814B model stands out for its dual-channel capabilities, allowing users to generate simultaneous signals for testing multiple components or systems. This feature significantly enhances testing efficiency and flexibility for engineers. With built-in arbitrary waveform functionality, users can create custom waveforms, making the 6814B suitable for a wide range of applications including device characterization and signal processing research.

For those seeking a more compact solution, the Agilent 6813B provides essential signal generation features without compromising on performance. It is designed for a variety of applications across telecommunications and consumer electronics, featuring a straightforward interface and robust performance metrics.

Lastly, the 6811B is an entry-level yet capable model that supports a broad spectrum of testing needs. Perfect for educational and laboratory environments, it provides essential functionalities required for effective signal generation and analysis.

Overall, Agilent Technologies' 6843A, 6834B, 6814B, 6813B, and 6811B signal generators offer an array of features and technologies that cater to various application needs. Their precision, reliability, and user-oriented designs position them as invaluable assets in any testing environment, ensuring engineers can carry out their work with confidence and accuracy.