Agilent Technologies 6814B, 6834B, 6843A manual Table A-1. Performance Specifications1

Page 55

A

Specifications

Specifications

Performance specifications are warranted over the ambient temperature range of 0 to 40 oC. Unless otherwise noted, specifications are per phase for a sinewave with a resistive load at an output frequency range of 45 Hz to 5 kHz (45 Hz-1 kHz, Agilent 6843A) after a 30-minute warmup.

Table A-1. Performance Specifications1

Parameter

Phases:

Maximum Output Ratings rms Voltage2:

Power:

rms Current:

Repetitive peak Current:

Crest Factor (current):

Output Frequency Range:

Constant Voltage Ripple and Noise

Load Regulation:

Line Regulation:

Maximum Total Harmonic Distortion:

Programming Accuracy (@ 25oC ±5oC) rms Voltage:

Frequency:

Phase: (Agilent 6834B in 3-phase mode)

Agilent 6814B

Agilent 6834B

Agilent 6843A

1

3

1

1

 

150 V low range;

 

 

 

 

300 V high range

 

3 kVA

1.5 kVA/phase

4.5 kVA

4.8 kVA

20 A low range

10 A low range

30 A low range

32 A low range

10 A high range

5 A high range

15 A high range

16 A high range

80 A low range

40 A low range

120 A low range

96 A low range

40 A high range

20 A high range

60 A high range

48 A high range

4

4

4

3

 

45 Hz−5 kHz

 

45 Hz−1 kHz

 

−60 dB (20 kHz−10 MHz)

 

 

0.5%

 

 

0.1%

 

 

1% (45 Hz−1 kHz);

 

 

1% + 1%/kHz (>1 kHz−5 kHz)

 

 

0.15% + 0.3 V (45−100 Hz)

 

 

 

 

0.5% + 0.3 V (>100−500 Hz)

 

 

1% + 0.3 V (>500−5 kHz)

 

 

0.01% + 10 μHz

 

N/A

0.1º(45-100 Hz)

N/A

N/A

 

1º(>100−1 kHz)

 

 

 

1º+ 1%/kHz

 

 

 

(>1k−5 kHz)

 

 

Measurement Accuracy (@25oC ±5oC) rms Voltage

rms Current Frequency: Power (VA): Power (Watts): Power Factor:

1Specifications subject to change without notice.

2From line to neutral on Agilent 6834B

0.05%+ 250 mV (45 Hz − 1 kHz)

0.05% + 0.1%/kHz + 250 mV (>1 kHz − 5 kHz)

0.1% + 50 mA

0.1% + 25 mA

0.1% + 50 mA

0.01% + 0.01Hz

0.01% + 0.01Hz

0.01% + 0.01Hz

0.15% + 5 VA

0.15% + 3 VA

0.15% + 5 VA

0.15% + 5 W

0.15% + 3 W

0.15% + 5 W

0.01

0.01

0.01

0.05% + 250 mV

0.1% + 50 mA

0.01% + 0.01Hz

0.15% + 9 VA

0.15% + 9 W

0.01

55

Image 55
Contents User’s Guide AC Power Solutions Agilent Models 6814B, 6834B, and 6843ACertification Warranty InformationGeneral Safety SummarySafety Symbols EMC DeclarationPrinting History Acoustic Noise InformationTable of Contents Entry Keys Examples of Front Panel Programming Specifications Supplemental CharacteristicsPerforming the Calibration Procedure Error Number ListTopic Document OrientationLocation Agilent Part Number Safety ConsiderationsOptions, Accessories, and User Replaceable Parts Option DescriptionCapabilities DescriptionModel Description Front Panel/Remote Operation Output CharacteristicRanges Output VA Capability AC Source Output Characteristic in real-time modePage Items Supplied CleaningInspection Damage Packaging MaterialNot block the fan exhaust at the rear of the unit LocationBench Operation Rack MountingInput Connections Installing the Power CordInput Source and Line Fuse Output Connections Output ConnectionsAmpacity and Resistance of Stranded Copper Conductors Wire ConsiderationsVoltage Drops Current RatingsRemote Sense Connections Remote Sense ConnectionsOutput Rating Trigger ConnectionsDigital Connections OVP ConsiderationsController Connections Gpib ConnectorRS-232 Data Format Interface CommandsRS-232 Connector RS-232 InterfaceNull Modem Interface Lines Response Data Terminator Hardware HandshakePreliminary Checkout IntroductionCheckout Procedure Using the KeypadVolt Procedure Display ExplanationProtclear Currprot OFF VoltprotCurrlev CurrprotCase of Trouble Error MessagesLine Fuse Page Front Panel, Overall View Front Panel DescriptionAC+DC System Keys Display Command FunctionFunction Keys Annunciator On Phase SelectedImmediate Action Keys KBESSEL, Rect Scrolling KeysMeter Display Keys Display MeasurementDisplay Output Control KeysRST CLS Protection and Status Control KeysAbort Trigger and List Control KeysInitimmed IMMThrough Are used for entering numeric values Is the decimal Entry KeysSet the output to 120 V rms as follows Setting the Output Voltage AmplitudeProcedure for Single-Phase AC Sources Examples of Front Panel ProgrammingTo verify the output, you can measure it as follows Procedure for Three-Phase AC SourcesPhase 3 to 235 Vrms Action DisplaySetting a Protection Feature Setting the Output FrequencyOvercurrent protection feature as follows Voltm Step Using Transient Voltage ModesStep Transient VolttDcycle Pulse TransientVoltm Pulse WidthAction List TransientVoltm Fixed Voltm List Count Volt EOL Step Auto Trigger Delays and Phase SynchronizationExample Display Syncsour PhaseSyncphas Initimmed Example Voltm Step Syncsour Phase Syncphas InitimmedProgramming Slew Rates Using Slew Rates to Generate WaveformsSlewt Voltm FixedSlew Step SlewmCurrpeak Syncsour Phase SyncphasMeasuring Peak Inrush Current RangeAction Display To set the Gpib address, proceed as follows Setting the Gpib Address and RS-232 ParametersTo configure the RS-232 interface, proceed as follows Saving and Recalling Operating StatesAddress Noutputs Table A-1. Performance Specifications1 SpecificationsAgilent 6814B Agilent 6834B Agilent 6843A Table A-2. Supplemental Characteristics Supplemental CharacteristicsSpecifications a Page Equipment Required CharacteristicsRecommended Model Turn-On Checkout Procedure Test SetupPerforming the Verification Tests RMS Current Readback Accuracy Voltage Programming and Measurement AccuracyAction Normal Result Agilent 6843A Current Measurement Accuracy Performing the Calibration ProcedureAgilent 6814B Current Measurement Accuracy Agilent 6834B Current Measurement AccuracyFront Panel Calibration Enable Calibration ModeFront Panel Calibration Menu Calibrating the OVP trip point Calibrating and Entering Voltage Calibration ValuesCalibrating and Entering Current Calibration Values Calpass Changing the Calibration PasswordCalibrating the Output Impedance Agilent 6843A only Saving the Calibration ConstantsAgilent Calibration Program Listing Calibration Error MessagesTable B-3. Gpib Calibration Error Messages Calibration Over the GpibFigure B-2. Calibration Program Listing Sheet 1 Figure B-2. Calibration Program Listing Sheet 2 Page Table C-1. Error Numbers Error Number ListError Messages Error Messages C Page Index Index Index Japan United States Latin AmericaCanada Australia/New Zealand Europe Asia PacificManual Updates
Related manuals
Manual 20 pages 27.01 Kb Manual 187 pages 38.86 Kb

6834B, 6843A, 6814B specifications

Agilent Technologies, a leader in electronic test and measurement equipment, offers a range of powerful signal sources including the 6843A, 6834B, 6814B, 6813B, and 6811B models. These instruments are designed to support various applications in research, development, and manufacturing, providing precise signal generation capabilities.

The Agilent 6843A is a versatile signal generator known for its exceptional frequency range and modulation capabilities. It supports an extensive bandwidth, making it ideal for applications that require high-frequency signal generation. With its superior phase noise performance, the 6843A is an excellent choice for radar, wireless communications, and electronic warfare applications. The instrument features an intuitive user interface, allowing engineers to set parameters quickly and efficiently.

Next, the Agilent 6834B offers exceptional performance characteristics, including high output power and low distortion. This signal generator is particularly noted for its ability to produce complex modulation formats, making it suitable for testing advanced wireless communication systems. With a reliable and stable output, the 6834B ensures accurate and repeatable measurements, which is vital for thorough testing processes.

The 6814B model stands out for its dual-channel capabilities, allowing users to generate simultaneous signals for testing multiple components or systems. This feature significantly enhances testing efficiency and flexibility for engineers. With built-in arbitrary waveform functionality, users can create custom waveforms, making the 6814B suitable for a wide range of applications including device characterization and signal processing research.

For those seeking a more compact solution, the Agilent 6813B provides essential signal generation features without compromising on performance. It is designed for a variety of applications across telecommunications and consumer electronics, featuring a straightforward interface and robust performance metrics.

Lastly, the 6811B is an entry-level yet capable model that supports a broad spectrum of testing needs. Perfect for educational and laboratory environments, it provides essential functionalities required for effective signal generation and analysis.

Overall, Agilent Technologies' 6843A, 6834B, 6814B, 6813B, and 6811B signal generators offer an array of features and technologies that cater to various application needs. Their precision, reliability, and user-oriented designs position them as invaluable assets in any testing environment, ensuring engineers can carry out their work with confidence and accuracy.