Agilent Technologies 6834B manual United States Latin America, Canada Australia/New Zealand, Japan

Page 78

Agilent Sales and Support Offices

For more information about Agilent Technologies test and measurement products, applications, services, and for a current sales office listing, visit our web site: http://www.agilent.com/find/tmdir

You can also contact one of the following centers and ask for a test and measurement sales representative.

United States:

Latin America:

Agilent Technologies

Agilent Technologies

Test and Measurement Call Center

Latin American Region Headquarters

P.O. Box 4026

5200 Blue Lagoon Drive, Suite #950

Englewood, CO 80155-4026

Miami, Florida 33126

(tel) 1 800 452 4844

U.S.A.

 

(tel) (305) 267 4245

 

(fax) (305) 267 4286

Canada:

Australia/New Zealand:

Agilent Technologies Canada Inc.

Agilent Technologies Australia Pty Ltd

5150 Spectrum Way

347 Burwood Highway

Mississauga, Ontario

Forest Hill, Victoria 3131

L4W 5G1

(tel) 1-800 629 485 (Australia)

(tel) 1 877 894 4414

(fax) (61 3) 9272 0749

 

(tel) 0 800 738 378 (New Zealand)

 

(fax) (64 4) 802 6881

Europe:

Asia Pacific:

Agilent Technologies

Agilent Technologies

Test & Measurement European Marketing Organisation

24/F, Cityplaza One, 1111 King’s Road,

P.O. Box 999

Taikoo Shing, Hong Kong

1180 AZ Amstelveen

tel: (852)-3197-7777

The Netherlands

fax: (852)-2506-9284

(tel) (31 20) 547 9999

 

Japan:

Agilent Technologies Japan Ltd. Measurement Assistance Center

9-1, Takakura-Cho, Hachioji-Shi, Tokyo 192-8510, Japan

(tel) (81) 426 56 7832 (fax) (81) 426 56 7840

Technical data is subject to change.

78

Image 78
Contents AC Power Solutions Agilent Models 6814B, 6834B, and 6843A User’s GuideWarranty Information CertificationSafety Summary GeneralSafety Symbols Declaration EMCAcoustic Noise Information Printing HistoryTable of Contents Error Number List Specifications Supplemental CharacteristicsPerforming the Calibration Procedure Entry Keys Examples of Front Panel ProgrammingDocument Orientation TopicLocation Option Description Safety ConsiderationsOptions, Accessories, and User Replaceable Parts Agilent Part NumberDescription CapabilitiesModel Description Output Characteristic Front Panel/Remote OperationRanges AC Source Output Characteristic in real-time mode Output VA CapabilityPage Damage Packaging Material CleaningInspection Items SuppliedRack Mounting LocationBench Operation Not block the fan exhaust at the rear of the unitInstalling the Power Cord Input ConnectionsInput Source and Line Fuse Output Connections Output ConnectionsCurrent Ratings Wire ConsiderationsVoltage Drops Ampacity and Resistance of Stranded Copper ConductorsRemote Sense Connections Remote Sense ConnectionsOVP Considerations Trigger ConnectionsDigital Connections Output RatingGpib Connector Controller ConnectionsRS-232 Interface Interface CommandsRS-232 Connector RS-232 Data FormatHardware Handshake Null Modem Interface Lines Response Data TerminatorIntroduction Preliminary CheckoutUsing the Keypad Checkout ProcedureProcedure Display Explanation VoltProtclear Currprot VoltprotCurrlev Currprot OFFError Messages Case of TroubleLine Fuse Page Front Panel Description Front Panel, Overall ViewAC+DC Display Command Function System KeysAnnunciator On Phase Selected Function KeysImmediate Action Keys Display Measurement Scrolling KeysMeter Display Keys KBESSEL, RectOutput Control Keys DisplayRST Protection and Status Control Keys CLSIMM Trigger and List Control KeysInitimmed AbortEntry Keys Through Are used for entering numeric values Is the decimalExamples of Front Panel Programming Setting the Output Voltage AmplitudeProcedure for Single-Phase AC Sources Set the output to 120 V rms as followsAction Display Procedure for Three-Phase AC SourcesPhase 3 to 235 Vrms To verify the output, you can measure it as followsSetting the Output Frequency Setting a Protection FeatureOvercurrent protection feature as follows Voltt Using Transient Voltage ModesStep Transient Voltm StepWidth Pulse TransientVoltm Pulse DcycleList Transient ActionVoltm Fixed Voltm List Count Trigger Delays and Phase Synchronization Volt EOL Step AutoSyncsour Phase Example DisplaySyncphas Initimmed Voltm Step Syncsour Phase Syncphas Initimmed ExampleUsing Slew Rates to Generate Waveforms Programming Slew RatesStep Slewm Voltm FixedSlew SlewtRange Syncsour Phase SyncphasMeasuring Peak Inrush Current CurrpeakSaving and Recalling Operating States Setting the Gpib Address and RS-232 ParametersTo configure the RS-232 interface, proceed as follows Action Display To set the Gpib address, proceed as followsAddress Noutputs Specifications Table A-1. Performance Specifications1Agilent 6814B Agilent 6834B Agilent 6843A Supplemental Characteristics Table A-2. Supplemental CharacteristicsSpecifications a Page Characteristics Equipment RequiredRecommended Model Test Setup Turn-On Checkout ProcedurePerforming the Verification Tests Voltage Programming and Measurement Accuracy RMS Current Readback AccuracyAction Normal Result Agilent 6834B Current Measurement Accuracy Performing the Calibration ProcedureAgilent 6814B Current Measurement Accuracy Agilent 6843A Current Measurement AccuracyEnable Calibration Mode Front Panel CalibrationFront Panel Calibration Menu Calibrating and Entering Voltage Calibration Values Calibrating the OVP trip pointCalibrating and Entering Current Calibration Values Saving the Calibration Constants Changing the Calibration PasswordCalibrating the Output Impedance Agilent 6843A only CalpassCalibration Over the Gpib Calibration Error MessagesTable B-3. Gpib Calibration Error Messages Agilent Calibration Program ListingFigure B-2. Calibration Program Listing Sheet 1 Figure B-2. Calibration Program Listing Sheet 2 Page Error Number List Table C-1. Error NumbersError Messages Error Messages C Page Index Index Index Europe Asia Pacific United States Latin AmericaCanada Australia/New Zealand JapanManual Updates
Related manuals
Manual 20 pages 27.01 Kb Manual 187 pages 38.86 Kb

6834B, 6843A, 6814B specifications

Agilent Technologies, a leader in electronic test and measurement equipment, offers a range of powerful signal sources including the 6843A, 6834B, 6814B, 6813B, and 6811B models. These instruments are designed to support various applications in research, development, and manufacturing, providing precise signal generation capabilities.

The Agilent 6843A is a versatile signal generator known for its exceptional frequency range and modulation capabilities. It supports an extensive bandwidth, making it ideal for applications that require high-frequency signal generation. With its superior phase noise performance, the 6843A is an excellent choice for radar, wireless communications, and electronic warfare applications. The instrument features an intuitive user interface, allowing engineers to set parameters quickly and efficiently.

Next, the Agilent 6834B offers exceptional performance characteristics, including high output power and low distortion. This signal generator is particularly noted for its ability to produce complex modulation formats, making it suitable for testing advanced wireless communication systems. With a reliable and stable output, the 6834B ensures accurate and repeatable measurements, which is vital for thorough testing processes.

The 6814B model stands out for its dual-channel capabilities, allowing users to generate simultaneous signals for testing multiple components or systems. This feature significantly enhances testing efficiency and flexibility for engineers. With built-in arbitrary waveform functionality, users can create custom waveforms, making the 6814B suitable for a wide range of applications including device characterization and signal processing research.

For those seeking a more compact solution, the Agilent 6813B provides essential signal generation features without compromising on performance. It is designed for a variety of applications across telecommunications and consumer electronics, featuring a straightforward interface and robust performance metrics.

Lastly, the 6811B is an entry-level yet capable model that supports a broad spectrum of testing needs. Perfect for educational and laboratory environments, it provides essential functionalities required for effective signal generation and analysis.

Overall, Agilent Technologies' 6843A, 6834B, 6814B, 6813B, and 6811B signal generators offer an array of features and technologies that cater to various application needs. Their precision, reliability, and user-oriented designs position them as invaluable assets in any testing environment, ensuring engineers can carry out their work with confidence and accuracy.