Sherwood EG40 DV Operating Instructions, For Your Safety Read Completely Before Operating

Page 6

Operating Instructions

FOR YOUR SAFETY READ COMPLETELY BEFORE OPERATING.

LIGHTING INSTRUCTIONS:

CAUTION: Hot while operating. Do not touch, severe burns may result. Keep children, clothing, furniture, gasoline or other flammable vapors away.

CAUTION: Do not operate this fireplace with the glass removed, cracked or broken. Replacement of the panel(s) should be done by a licensed or qualified person! This appliance needs fresh air for safe operation and must be installed with provisions for combustion and ventilation air. See installation and operating instructions manual. Keep burner and control compartment clean.

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage, or loss of life. Refer to owner's information manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or the gas supplier. See installation and operating instructions accompanying appliance. Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

FOR YOUR SAFETY READ BEFORE OPERATING

WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING

PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

A)This appliance is equipped with a pilot, which must be lit by hand by following these instructions exactly.

B)BEFORE LIGHTING smell all around the appliance area for

gas and next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance. Do not touch any electrical switch: do not use any phone in your building. Immediately call your gas supplier from a neighbor's phone. Follow the gas suppliers instructions. If you cannot reach your gas supplier, call the fire department.

C)Use only your hand to push in or turn the gas control knob; NEVERuse tools. If the knob will not push in or turn by hand, do not try to repair it. Call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D)Do not use this appliance if any part has been under water.

Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas controlwhich has been under water.

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information above on this label.

2.Turn off all electrical power to this appliance.

3.Turn off the gas control knob clockwise to the off position.

4.Open door. Wait fIve (5) minutes to clear out any gas. Close door. If you smell gas STOP! Follow “B” in the above safety information. If you do not smell gas go to the next step.

5.Find pilot-located to the right between the front and rear burner.

Turn the gas control knob counter-clockwise to “PILOT”. Push the gas control in fully and hold, keep knob depressed for about 30 seconds after the pilot is lit. Release knob. If pilot goes out, repeat steps 4

through 5.

WARNING: this gas valve has a lockout device, which will not allow thepilot burner to be relit until the thermocouple has cooled. If the knob doesdoes not pop up when released, stop and immediately call your service technician or gas supplier. If the pilot does not stay lit after several tries, turn the gas control knob to “OFF” and call your service technician or gas supplier.

6. Turn the gas control knob counter clockwise to the “ON” position. Flip the burner switch to “ON” THEN TURN

THE “HI/LOW” knob to the

TP TH

 

OUT

IN

 

desired setting.

 

 

 

 

 

 

 

 

 

7. Turn on the electrical

TP

H

O

 

 

L

OFF

 

 

I

 

 

 

 

 

P

TH

 

 

I

 

 

 

L

power to the unit.

 

 

 

T

O

 

 

 

NO

 

 

 

 

 

 

 

 

P

 

 

 

 

 

TO LI

 

 

 

TO TURN OFF GAS TO APPLIANCE

1. Flip burner switch to “OFF”

 

3. Turn off all electrical power to the appliance if service is to

2. Turn the gas control knob clockwise

to the “OFF” position.

be performed.

Figure 2: Lighting Instructions.

6

Image 6
Contents EG40 DV Safety Precautions GeneralTable of Contents Codes And Approvals Vented GAS Fireplace Heater EG40 DV NG/LPGSpecifications EG40 Exterior DimensionsFor Your Safety Read Completely Before Operating Operating InstructionsThere is a separate venturies for each burner, see Figure Component Sound & ReasonMaintenance and Service Removing the DoorBurner is lined up Kit Parts List Conversion Kit InstallationMust be not visible Removing valve ScrewInitial Installation Qualified Installers onlyCommon Vertical Installation Do not interfere with the structural integrity of the walls Vent Termination Restrictions KIT Components Assembly of Venting Kit Manufacturer Trade Name Nominal Sizes SV4EBR45 Vent restrictor ring End of the pipes and fittings, are Installing Vent Cap with Vinyl Siding Stand-Off Assemble the desired lengths of black pipe Use of Wall Straps Multi-Story Vent Pipe Installation Insulation33a-2002 Test Methods and the Resulting ITS/WH Must be connected to a grounding rod Must be bolted securely to the floorManifold Pressure Natural Gas Propane Front BurnerRear Burner Min. Manifold PressureSecondary Installation Log PlacementRemove door to clean glass Trouble Shooting Problem Possible Cause SolutionParts List T. Nova Valve Convertible 50-1421Parts List Parts Diagram Chassis Parts Diagram Gas Tray & Door Warranty To the DealerWarranty Warranty Installation Data Sheet