Sherwood EG40 DV owner manual Kit Parts List, Conversion Kit Installation

Page 10

Maintenance And Service

FUEL CONVERSION:

TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY

Please read and understand these instructions before installing.

Warning: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service agency is responsible for the proper installation of this kit. The installation is not proper or complete until the operation of the converted appliance is checked as specified in the manufacturer’s instructions supplied with the kit.

Kit Parts List:

1 - Orifice (NG - Front #48 DMS & Rear #43 DMS or LP - Front #56 DMS & Rear #54 DMS)

1 - Pilot Injector (NG 0.62 mm; LP 0.35 mm)

1 - Installation instruction sheet

1 - Conversion label

Carefully inspect all parts supplied with this conversion kit. If any parts have been damaged or are missing, contact your dealer, distributor or courier company to have them replaced before starting this installation.

Conversion Kit Installation:

1.Turn control knob on the gas valve to the “OFF” position and shut the gas supply off at the shut-off valve upstream of the unit. CAUTION: The gas supply must be shut off prior to disconnecting the electrical power and before proceeding with the conversion. Allow the valve and unit to cool down to room temperature.

2.Remove the glass as shown in the MAINTENANCE AND SERVICE - OPENING THE DOOR.

3.Carefully remove the log set and ember material if they are installed.

4.Remove the burner as shown in the MAINTENANCE AND SERVICE - BURNER REMOVAL.

5.Convert the burner orifice(s):

a)Remove the main burner orifice with a 1⁄2 inch deep socket.

b)Put a bead of pipe-thread sealant or approved Teflon tape on the orifice threads before installing into the brass elbow.

c)Install the new orifice(s) from the kit into the brass elbow.

6.Convert the pilot injector:

a)Pull the pilot hood straight up to access the pilot injector.

b)Using a 5/32” or 4 mm Allen key, remove the pilot injector.

c)Install the new pilot injector supplied with this conversion kit. Simply screw the new injector inside the pilot hood using the Allen key,

d)Reinstall the hood by placing the hood on the assembly, line up the key way, and snap into place.

Figure 9: Removing

valve cap.

10

Image 10
Contents EG40 DV Safety Precautions GeneralTable of Contents Codes And Approvals Vented GAS Fireplace Heater EG40 DV NG/LPGSpecifications EG40 Exterior DimensionsFor Your Safety Read Completely Before Operating Operating InstructionsThere is a separate venturies for each burner, see Figure Component Sound & ReasonMaintenance and Service Removing the DoorBurner is lined up Kit Parts List Conversion Kit InstallationMust be not visible Removing valve ScrewInitial Installation Qualified Installers onlyCommon Vertical Installation Do not interfere with the structural integrity of the walls Vent Termination Restrictions KIT Components Assembly of Venting Kit Manufacturer Trade Name Nominal Sizes SV4EBR45 Vent restrictor ring End of the pipes and fittings, are Installing Vent Cap with Vinyl Siding Stand-Off Assemble the desired lengths of black pipe Use of Wall Straps Multi-Story Vent Pipe Installation Insulation33a-2002 Test Methods and the Resulting ITS/WH Must be connected to a grounding rod Must be bolted securely to the floorManifold Pressure Natural Gas Propane Front BurnerRear Burner Min. Manifold PressureSecondary Installation Log PlacementRemove door to clean glass Trouble Shooting Problem Possible Cause SolutionParts List T. Nova Valve Convertible 50-1421Parts List Parts Diagram Chassis Parts Diagram Gas Tray & Door Warranty To the DealerWarranty Warranty Installation Data Sheet