Sherwood EG40 DV owner manual There is a separate venturies for each burner, see Figure

Page 7

Operating Instructions

Figure 3: Pilot Burning.

ADJUSTING THE VENTURIES:

Figure 4: Gas Valve.

There is a separate venturies for each burner, see Figure 5.

Remove one screw from the cover plate located below the ash shelf and loosen the other screw (do not remove) swing the cover plate out of the way and tighten screw down to hold it in place.

With along screwdriver rotate spring clips to open or close the venturies to the desired setting.

The venturies allows the amount of air coming into the fireplace to be adjusted in order to accommodate different climates and venting arrangements. Start

Rear log holder

 

Front log holder

Ember tray &

Rear burner

front burner

 

Door

Venturies

Screwdrive

 

 

Gold bar

Air shutter cover plate

Figure 5: Venturi Adjustment.

the pilot and then the burner. Make sure the pilot flame is burning normally and none of the burner ports are plugged. Let the fireplace burn for roughly fifteen9minutes and then examine the flames, compare the flames to Figure 16.

The ideal flame will be blue at the base and light orange above. The flames should be of medium height. If the flames look like this, no venturi adjustment is needed. If the flames are fairly short and mostly blue, the fireplace is getting too much air. Therefore, the venturies should be closed slightly until the correct flames are achieved. Flames that are very orange, with tall, dark, stringy tips, are not getting enough air. Open the venturi until the flames clean up. If the venturi is opened, or closed all the way, and the correct flames cannot be attained, turn off the gas and contact the dealer.

Warning: Incorrect venturi adjustment may lead to improper combustion, which is a safety hazard. Contact the dealer if there is any concern about the venturi adjustment.

NORMAL SOUNDS DURING OPERATION:

 

Table 1: Normal Sounds

 

 

Component

Sound & Reason

 

 

EG40

Creaking when heating up or cooling down.

 

 

Burner

Light pop or poof when turned off; this is more common with LP units.

 

 

Temperature Sensor

Clinking when it senses to turn the blower on or off.

 

 

Pilot Flame

Quiet whisper while the pilot flame in on.

 

 

Blower / Fan

Air movement that increase and decreases with the speed of the blower. The

 

blower is pushing the heat from the fireplace into the room.

Gas Control Valve

Dull click when turning on or off, this is the valve opening and closing.

 

 

7

Image 7
Contents EG40 DV General Safety PrecautionsTable of Contents Vented GAS Fireplace Heater EG40 DV NG/LPG Codes And ApprovalsEG40 Exterior Dimensions SpecificationsOperating Instructions For Your Safety Read Completely Before OperatingComponent Sound & Reason There is a separate venturies for each burner, see FigureRemoving the Door Maintenance and ServiceBurner is lined up Conversion Kit Installation Kit Parts ListRemoving valve Screw Must be not visibleQualified Installers only Initial InstallationCommon Vertical Installation Do not interfere with the structural integrity of the walls Vent Termination Restrictions KIT Components Assembly of Venting Kit Manufacturer Trade Name Nominal Sizes SV4EBR45 Vent restrictor ring End of the pipes and fittings, are Installing Vent Cap with Vinyl Siding Stand-Off Assemble the desired lengths of black pipe Use of Wall Straps Insulation Multi-Story Vent Pipe Installation33a-2002 Test Methods and the Resulting ITS/WH Must be bolted securely to the floor Must be connected to a grounding rodMin. Manifold Pressure Natural Gas Propane Front BurnerRear Burner Manifold PressureLog Placement Secondary InstallationRemove door to clean glass Problem Possible Cause Solution Trouble ShootingT. Nova Valve Convertible 50-1421 Parts ListParts List Parts Diagram Chassis Parts Diagram Gas Tray & Door To the Dealer WarrantyWarranty Warranty Installation Data Sheet