Sherwood owner manual Codes And Approvals, Vented GAS Fireplace Heater EG40 DV NG/LPG

Page 4

Codes And Approvals

DIRECT VENT: This type is identified by the suffix DV. This appliance draws all of its air for combustion from outside the dwelling, through a specially designed vent pipe system.

This appliance has been tested and approved for installations from 0 ft to 4500 ft (1372 m) above sea level.

In the USA: The appliance may be installed at higher altitudes. Please refer to your American Gas Association guidelines which state: the sea level rated input of Gas Designed Appliances installed at elevations above 2000 ft (610 m) is to be reduced 4% for each 1000 ft (305 m) above sea level. Refer also to local authorities or codes which have jurisdiction in your area regarding the de-rate guidelines.

In Canada: When the appliance is installed at elevations above 4500 ft (1372 m), the certified high altitude rating shall be reduced at the rate of 4% for each additional 1000 ft (305 m).

This appliance has been tested by INTERTEK (Warnock Hersey) and found to comply with the established VENTED GAS FIREPLACE HEATER standards in CANADA and the USA as follows:

VENTED GAS FIREPLACE HEATER (EG40 DV NG/LPG)

TESTED TO: ANSI Z21.88a-2003/CSA 2.33a-2003 VENTED GAS FIREPLACE HEATERS

CAN/CGA 2.17-M91 GAS FIRED APPLIANCES FOR HIGH ALTITUDES

CSA P.4.1-02 TESTING METHOD FOR MEASURING ANNUAL FIREPLACE EFFICIENCY

This ENVIRO EG40 DV Fireplace:

Has been certified for use with either natural or propane gases. (See rating label.)

Is not for use with solid fuels.

Is approved for bedroom or bed sitting room. (IN CANADA: must be installed with a listed wall thermostat. IN USA: see current ANSI Z223.1 for installation instructions.)

Must be installed in accordance with local codes. If none exist, use current installation code CAN/CGA B149 in Canada or ANSI Z223.1/NFPA 54 in the USA.

Must be properly connected to an approved venting system and not connected to a chimney flue serving a separate solid-fuel burning appliance.

• Manufactured (mobile) home installation must be in accordance with the Manufactured Home Construction and Safety Standard, UL 307B, Title 24 CFR, Part 3280 and/or The Standard for Manufactured Home Installations, ANSI A225.1/NFPA 501A. The unit must be bolted to the floor of the mobile home and must be electrically grounded to the steel chassis.

Are approved for installation on combustible materials (i.e. Wood, carpet or linoleum).

Is not approved for closet or recessed installations.

IMPORTANT NOTICE (Regarding first fire up): When the unit is turned on for the first time, it should be turned onto high without the fan on for the first 4 hours. This will cure the paint, logs, gasket material and other products used in the manufacturing process. It is advisable to open a window or door, as the unit will start to smoke and can irritate some people. After the unit has gone through the first burn turn the unit off including the pilot, let the unit get cold then remove the glass door and clean it with a good gas fireplace glass cleaner, available at your local ENVIRO dealer.

4

Image 4
Contents EG40 DV Safety Precautions GeneralTable of Contents Codes And Approvals Vented GAS Fireplace Heater EG40 DV NG/LPGSpecifications EG40 Exterior DimensionsFor Your Safety Read Completely Before Operating Operating InstructionsThere is a separate venturies for each burner, see Figure Component Sound & ReasonMaintenance and Service Removing the DoorBurner is lined up Kit Parts List Conversion Kit InstallationMust be not visible Removing valve ScrewInitial Installation Qualified Installers onlyCommon Vertical Installation Do not interfere with the structural integrity of the walls Vent Termination Restrictions KIT Components Assembly of Venting Kit Manufacturer Trade Name Nominal Sizes SV4EBR45 Vent restrictor ring End of the pipes and fittings, are Installing Vent Cap with Vinyl Siding Stand-Off Assemble the desired lengths of black pipe Use of Wall Straps Multi-Story Vent Pipe Installation Insulation33a-2002 Test Methods and the Resulting ITS/WH Must be connected to a grounding rod Must be bolted securely to the floorNatural Gas Propane Front Burner Rear BurnerManifold Pressure Min. Manifold PressureSecondary Installation Log PlacementRemove door to clean glass Trouble Shooting Problem Possible Cause SolutionParts List T. Nova Valve Convertible 50-1421Parts List Parts Diagram Chassis Parts Diagram Gas Tray & Door Warranty To the DealerWarranty Warranty Installation Data Sheet