Sherwood EG40 DV owner manual Parts List

Page 33

Parts List

Reference

Part Description

Part Number

Number

 

 

14

Side Panel

EG40-086

15

DV Stove Top

EG40-087A

 

Firebox Baffle

EG40-088

 

Stove Top Baffle DV

EG40-091A

 

Venturi Cover Plate

EG40-097

16

Front Venturi

EG40-098

17

Bar Set - Painted (3 pieces)

EG40-114

17

Bar Set - Gold (3 pieces)

EG40-115

17

Bar Set - Nickel (3 pieces)

50-478

 

Burner Gasket

EG40-120

 

Steel Brick Liner

EG40-129

 

Brick Liner Backing

EG40-130

18

Pedestal Door

EG40-135

 

LP to NG Conversion Kit

EG40-200

 

NG to LP Conversion Kit

EG40-202

19

Ash Sill

EG40-213

20

Door Hinge (Set of 2)

EG40-302

21

Fan Mount

EG40-304

22

Pedestal Box Cover

EG40-307

23

Burner Control Assembly NG

30-014

23

Burner Control Assembly LP

30-015

24

Front Pan Burner

30-016

25

Rear Burner with Venturi

30-017

 

Pilot 1/8” Tube with Ferules

30-043

 

Log Set Complete

50-081

26

Blank Orifice #73

50-343

27

Door Cover - Gold

50-480

27

Door Cover - Painted

50-776

27

Door Cover - Brushed Nickel

50-1063

28

Convection Blower - 115V

50-514

 

16” Ignitor Wire

50-652

 

IEC Power Cord Inlet Socket

50-713

 

Burner Tray Top NG & LP

50-774

 

Vent Termination Kit

50-950

 

Conversion Kit LP To NG Convertible

50-1432

 

 

 

 

Conversion Kit NG To LP Convertible

50-1433

 

 

 

 

S.I.T. Valve Conversion Screw with O-ring

50-1450

 

 

 

 

S.I.T. Valve Conversion Screw Cap

50-1451

 

 

 

33

Image 33
Contents EG40 DV General Safety PrecautionsTable of Contents Vented GAS Fireplace Heater EG40 DV NG/LPG Codes And ApprovalsEG40 Exterior Dimensions SpecificationsOperating Instructions For Your Safety Read Completely Before OperatingComponent Sound & Reason There is a separate venturies for each burner, see FigureRemoving the Door Maintenance and ServiceBurner is lined up Conversion Kit Installation Kit Parts ListRemoving valve Screw Must be not visibleQualified Installers only Initial InstallationCommon Vertical Installation Do not interfere with the structural integrity of the walls Vent Termination Restrictions KIT Components Assembly of Venting Kit Manufacturer Trade Name Nominal Sizes SV4EBR45 Vent restrictor ring End of the pipes and fittings, are Installing Vent Cap with Vinyl Siding Stand-Off Assemble the desired lengths of black pipe Use of Wall Straps Insulation Multi-Story Vent Pipe Installation33a-2002 Test Methods and the Resulting ITS/WH Must be bolted securely to the floor Must be connected to a grounding rodRear Burner Natural Gas Propane Front BurnerManifold Pressure Min. Manifold PressureLog Placement Secondary InstallationRemove door to clean glass Problem Possible Cause Solution Trouble ShootingT. Nova Valve Convertible 50-1421 Parts ListParts List Parts Diagram Chassis Parts Diagram Gas Tray & Door To the Dealer WarrantyWarranty Warranty Installation Data Sheet