Sherwood EG40 DV owner manual Burner is lined up

Page 9

Maintenance and Service

3.Vacuum the bottom of the firebox thoroughly. Carefully clean off any dust on the logs and remove any lint from the main burner and pilot burner.

4.After carefully replacing the log and embers in their correct positions (see Secondary Installation - Installation of Log Set and Embers), and the door has been resealed, re-light the pilot, following the instructions on the lighting label attached to the unit.

CLEANING PLATED SURFACES:

It is important to note that fingerprints and other marks can leave a permanent stain on plated finishes. To avoid this, give the face a quick wipe with denatured alcohol on a soft cloth BEFORE lighting the fireplace. Never clean the face when it is not cool. Do not use other cleaners as they may leave a residue, which can become permanently etched into the surface.

BURNER REMOVAL:

The burner may need to be removed for a few reasons, including cleaning under the burner, converting the unit to a different gas type, or to replace the burner altogether. Proceed only when the unit has completely cooled down.

1.Remove the door as shown in the MAINTENANCE AND SERVICE - OPENING THE DOOR.

2.Remove the two (2) T-20 screws that hold

the burner in place; one (1) at each of the rear burner (see Figure 7).

3. Lift the burner assembly (both the front and rear burners) straight up then out.

To re-install the burner follow steps 1-3 in

 

reverse. When placing the burner back in the

 

unit ensure that the venturi box under the

Figure 7: Screws holding Burner.

burner is lined up.

REPLACING THE BLOWER:

 

1.

Turn the unit off, allow it to cool down completely, and

 

remove the door as shown in the MAINTENANCE AND SERVICE

 

- OPENING THE DOOR..

2. Remove the log set and brick liner.

3.

Remove the burner tray assembly, see MAINTENANCE AND

 

SERVICE - BURNER REMOVAL.

4.

Remove the four (4) 5/16” bolts that hold the blower

 

mounting plate to the back firewall. Use a light lubricating

 

oil on screws before removal.

5.

Carefully pull the blower assembly into the firebox (see

 

Figure 7) disconnect the blower leads from the harness and

 

remove blower.

6.

To re-install, check mounting plate gasket if damaged

 

replace with new one and reverse steps 1 through 4. Refer

Figure 8: Blower (Fan) Removal.

to “SECONDARY INSTALLATION - LOG SET AND EMBERS INSTALLATION”.

9

Image 9
Contents EG40 DV General Safety PrecautionsTable of Contents Vented GAS Fireplace Heater EG40 DV NG/LPG Codes And ApprovalsEG40 Exterior Dimensions SpecificationsOperating Instructions For Your Safety Read Completely Before OperatingComponent Sound & Reason There is a separate venturies for each burner, see FigureRemoving the Door Maintenance and ServiceBurner is lined up Conversion Kit Installation Kit Parts ListRemoving valve Screw Must be not visibleQualified Installers only Initial InstallationCommon Vertical Installation Do not interfere with the structural integrity of the walls Vent Termination Restrictions KIT Components Assembly of Venting Kit Manufacturer Trade Name Nominal Sizes SV4EBR45 Vent restrictor ring End of the pipes and fittings, are Installing Vent Cap with Vinyl Siding Stand-Off Assemble the desired lengths of black pipe Use of Wall Straps Insulation Multi-Story Vent Pipe Installation33a-2002 Test Methods and the Resulting ITS/WH Must be bolted securely to the floor Must be connected to a grounding rodRear Burner Natural Gas Propane Front BurnerManifold Pressure Min. Manifold PressureLog Placement Secondary InstallationRemove door to clean glass Problem Possible Cause Solution Trouble ShootingT. Nova Valve Convertible 50-1421 Parts ListParts List Parts Diagram Chassis Parts Diagram Gas Tray & Door To the Dealer WarrantyWarranty Warranty Installation Data Sheet