Outdoor Unit ––––––––––––––––––––––––––––––––––––––––––––––––––––––––

INSTALLATION MANUAL

RAV-SM560AT-E/RAV-SM800AT-E

 

1

PRECAUTIONS FOR SAFETY

4

5

EVACUATING

13

2

ACCESSORY AND REFRIGERANT

6

6

ELECTRICAL WORK

15

3

SELECTION OF INSTALLATION

6

7

FINAL INSTALLATION CHECKS

16

4

REFRIGERANT PIPING

11

 

 

 

Outdoor Unit ––––––––––––––––––––––––––––––––––––––––––––––––––––––––

INSTALLATION MANUAL

RAV-SM1100AT-E/RAV-SM1400AT-E

 

1

PRECAUTIONS FOR SAFETY

18

5

EVACUATING

26

2

ACCESSORY AND REFRIGERANT

20

6

ELECTRICAL WORK

28

3

SELECTION OF INSTALLATION

20

7

FINAL INSTALLATION CHECKS

29

4

REFRIGERANT PIPING

24

 

 

 

Indoor Unit –––––––––––––––––––––––––––––––––––––––––––––––––––––

RAV-SM561BT-E/RAV-SM801BT-E/RAV-SM1101BT-E/RAV-SM1401BT-E

 

Concealed Duct Type

 

OWNER’S NANUAL

 

ACCESSORIES (SOLD SEPARATELY)

31

TIMER OPERATION

38

PRECAUTIONS FOR SAFETY

31

MAINTENANCE

40

PARTS NAME

33 AIR CONDITIONER OPERATIONS AND PERFORMANCE

41

PARTS NAME OF REMOTE CONTROLLER

34

RE-INSTALLATION

42

CORRECT USAGE

37

TROUBLES AND CAUSES

42

AUTOMATIC OPERATION (Auto Changeover)

37 TROUBLES AND CAUSES (Concerning Remote Controller) ...

44

Concealed Duct Type

 

INSTALLATION MANUAL

 

Accessory parts and Parts to be procured locally

45

7 EVACUATING

61

1

PRECAUTIONS FOR SAFETY

46

8 ELECTRICAL WORK

63

2

SELECTION OF INSTALLATION PLACE

48

9 TEST RUN

65

3

INSTALLATION OF INDOOR UNIT

49

10

TROUBLESHOOTING

66

4

AIR DUCTING WORK

53

11

Applicable Controls

67

5

DRAIN PIPING WORK

58

12

INSTALLATION/SERVICING TOOLS

70

6

REFRIGERANT PIPING

60

13

MAINTENANCE

70

Accessories ––––––––––––––––––––––––––––––––––––––––––––––––––––

OWNER’S MANUAL

 

 

WEEKLY TIMER FOR AIR CONDITIONER (SPLIT TYPE)

 

<Program Weekly Timer Type>

RBC-EXW21E

72

REMOTE CONTROLLER FOR AIR CONDITIONER

 

<Simple Operation Type>

RBC-AS21E

78

SM560AT-E

SM800AT-E

RAV-

RAV-

SM1100AT-E

SM1400AT-E

RAV-

RAV-

RAV-SM561BT-E/RAV-SM801BT-E RAV-SM1101BT-E/RAV-SM1401BT-E

INSTALLATION MANUAL

Standard Remote Controller

Simple Remote Controller

Program Weekly Timer

Remote sensor

Zeolite-3G Deodorant Filter

High-Efficiency Filter High-Efficiency filter (65%) High-Efficiency filter (90%)

Deodorant Filter, Ammonium Filter

Deodorant Filter

Ammonium Filter

RBC-AMT21E

81

RBC-AS21E

82

RBC-EXW21E

83

TCB-TC21LE

84

TCB-FPC11BE/TCB-FPC21BE/TCB-FPC31BE/TCB-FPC41BE

85

..................................................................................................................................

86

TCB-UFM11BE/TCB-UFM21BE/TCB-UFM31BE/TCB-UFM41BE

 

TCB-UFH51BE/TCB-UFH61BE/TCB-UFH71BE/TCB-UFH81BE

 

..................................................................................................................................

87

TCB-DF11BE/TCB-DF21BE/TCB-DF31BE/TCB-DF41BE

 

TCB-DF11BE-AM/TCB-DF21BE-AM/TCB-DF31BE-AM/TCB-DF41BE-AM

 

ACCESSORIES

Page 3
Image 3
Toshiba R410A service manual Concealed Duct Type, Accessory parts and Parts to be procured locally, Applicable Controls

R410A specifications

Toshiba R410A is a highly regarded refrigerant known for its efficiency and environmental benefits. This hydrofluorocarbon (HFC) mixture is widely used in various air conditioning and refrigeration applications due to its excellent thermodynamic properties. One of the standout features of R410A is its superior energy efficiency, which contributes to lower energy consumption and reduced CO2 emissions in HVAC systems.

One significant advantage of R410A over older refrigerants, such as R22, is its lower ozone depletion potential (ODP). R410A has an ODP of zero, making it a more environmentally friendly choice. This characteristic aligns with global initiatives aimed at protecting the ozone layer and promoting sustainable practices. The shift to R410A has been supported by government regulations in many countries, phasing out older, more harmful refrigerants.

Toshiba has incorporated advanced technologies in its R410A compatible products, enhancing performance and reliability. Among these technologies is the inverter technology that allows the compressor to operate at variable speeds. This functionality leads to improved temperature regulation, reduced noise levels, and further energy savings. Inverter systems provide precise control over the cooling and heating processes, allowing for a comfortable indoor environment while minimizing wastage of energy.

R410A also exhibits excellent heat transfer properties, which boosts cooling capacity. This feature makes it suitable for large-scale HVAC systems, including commercial and industrial applications. Its high-pressure characteristics enable the design of more compact and efficient components, allowing for smaller units and easier installation.

Furthermore, Toshiba's dedication to technological innovation is visible in its commitment to research and development. The company continuously strives to optimize systems that utilize R410A, focusing on reliability and longevity. This includes improved compressor designs, enhanced heat exchangers, and the integration of smart controls that adapt to the varying load conditions in real-time.

In terms of safety, R410A is classified as non-toxic and non-flammable under normal conditions, making it a safe choice for use in residential and commercial settings. However, it is important to note that R410A operates at higher pressures compared to traditional refrigerants, necessitating proper equipment design and handling procedures.

In conclusion, Toshiba R410A stands out in the market for its energy efficiency, environmental safety, and technological advancements. It is an ideal refrigerant for modern HVAC applications, contributing to both comfort and sustainability. As the industry continues to evolve, R410A remains a pivotal element in the quest for responsible and efficient refrigeration solutions.