INSTALLATION MANUAL Remote sensor

To Personnel Charged in Installation (Electric) Work and Service

MODEL : TCB-TC21LE

 

 

Accessory parts

 

Fix it with the spacer, but not so strongly. If the remote

 

 

 

 

Part Name

Q’ty

Part Name

Q’ty

sensor does not fit closely to the wall, adjust it by

cutting off the spacer.

 

Remote sensor

 

Spacer

 

 

 

2

3. Connect the remote sensor cable (2 cores) to the

 

1

 

(200mm-cable

 

 

terminal numbers of the indoor unit.

 

 

 

attached)

 

Wire joint

 

(Applying AC 220/230/240V breaks the unit.)

Small screw

 

2

 

 

4. Install the remote sensor body by matching to hooks

 

 

 

M4 x 25

2

 

 

on the rear case and putting into the hooks.

 

Cable clamper

 

 

 

1

 

 

 

 

 

 

 

Wood screw

 

Installation Manual

 

How to perform cabling of the remote sensor

 

2

1

 

 

 

 

 

 

 

 

 

In case of using the remote sensor as a concealed type

Requirement to install the remote sensor

Installation place

• Install the remote sensor at a position with height 1 to

1.5m from the floor, where the average temperature in

the room can be felt.

• Do not install the remote sensor at a place exposed to

the direct sunlight or direct outside air, such as a side of

window, etc.

• Do not install the remote sensor at a place behind

something or rear side of something, where air flow is

poor in the room.

• Connection diagram

 

 

 

Approx. 200mm

Terminal block

A

W

Remote

for remote

 

controller cable

B

B

sensor

in indoor unit

 

 

 

 

W : White

Remote sensor cable

Connecting

Cable from

B : Black

(Procured locally)

section

remote sensor body

Non polarity, 2 core cable is used..

Use 0.5mm² to 2 mm² cable.

Do not install the remote controller near the freezing

 

box or refrigerator because water proof or drop-proof is

 

not applied to this remote controller.

Be sure to set the remote sensor vertically on the wall

 

surface, etc.

How to install the remote sensor

NOTE 1 : Avoid to twist the remote sensor cable with the power supply cable, etc. or to store them in the same metal pipe, otherwise it causes a malfunction.

Attached wire joint (White, 2 pcs.)

Remote sensor cable

 

Cable from

Wire joint, CE-1

remote sensor body

(Nichiatsu)

1)Peel the sheath of the cable to be connected by approx. 14mm.

2)Twist two cables and pressure-connect them using a wire joint.

3)When an exclusive pressure-connecting tool is not used or soldering connection is used, apply insulation process with an insulation tape.

NOTE 2 : Install the remote sensor apart from the generation source of noise.

NOTE 3 : When noise is induced to the power source of the indoor unit, some measures such as mounting the noise filter is necessary.

• In case of using the remote sensor as a concealed type

Rear case Spacer

Remote sensor body

Wall

Small screws

M4 x 25 (2 pcs.)

1.Inserting a minus screwdriver, etc. into the groove at the lower side of the remote sensor body, force open the rear case to remove it.

2.Using the attached M4 screws (2 pcs.), fix the rear case of the remote sensor. Before installation, press to open the screw hole with a screwdriver, etc.

Requirement for using the remote sensor

together with the remote controller

How to install

For the above control, install the remote sensor in the following procedure.

1.Set the remote controller as the master remote controller.

2.Do not change the remote sensor switch in the master remote controller for correct temperature control by remote sensor.

Basic cabling diagram

1.Connect cables without miswiring. (Miswiring breaks the unit.)

2.In a case to operate an indoor unit from the remote sensors and the remote controller.

Remote

 

 

 

 

Remote

 

 

 

 

(Sold

 

 

 

 

controller

 

 

 

 

sensor

 

 

 

 

 

 

 

 

separately)

 

 

 

 

(Master)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remote controller cable

 

 

 

 

 

 

 

 

(Procured locally)

Terminal block for remote controller cable

A B

Indoor unit

Earth

84

85464359427000 (EN)-

Page 84
Image 84
Toshiba R410A service manual Accessory parts, Requirement to install the remote sensor, How to install the remote sensor

R410A specifications

Toshiba R410A is a highly regarded refrigerant known for its efficiency and environmental benefits. This hydrofluorocarbon (HFC) mixture is widely used in various air conditioning and refrigeration applications due to its excellent thermodynamic properties. One of the standout features of R410A is its superior energy efficiency, which contributes to lower energy consumption and reduced CO2 emissions in HVAC systems.

One significant advantage of R410A over older refrigerants, such as R22, is its lower ozone depletion potential (ODP). R410A has an ODP of zero, making it a more environmentally friendly choice. This characteristic aligns with global initiatives aimed at protecting the ozone layer and promoting sustainable practices. The shift to R410A has been supported by government regulations in many countries, phasing out older, more harmful refrigerants.

Toshiba has incorporated advanced technologies in its R410A compatible products, enhancing performance and reliability. Among these technologies is the inverter technology that allows the compressor to operate at variable speeds. This functionality leads to improved temperature regulation, reduced noise levels, and further energy savings. Inverter systems provide precise control over the cooling and heating processes, allowing for a comfortable indoor environment while minimizing wastage of energy.

R410A also exhibits excellent heat transfer properties, which boosts cooling capacity. This feature makes it suitable for large-scale HVAC systems, including commercial and industrial applications. Its high-pressure characteristics enable the design of more compact and efficient components, allowing for smaller units and easier installation.

Furthermore, Toshiba's dedication to technological innovation is visible in its commitment to research and development. The company continuously strives to optimize systems that utilize R410A, focusing on reliability and longevity. This includes improved compressor designs, enhanced heat exchangers, and the integration of smart controls that adapt to the varying load conditions in real-time.

In terms of safety, R410A is classified as non-toxic and non-flammable under normal conditions, making it a safe choice for use in residential and commercial settings. However, it is important to note that R410A operates at higher pressures compared to traditional refrigerants, necessitating proper equipment design and handling procedures.

In conclusion, Toshiba R410A stands out in the market for its energy efficiency, environmental safety, and technological advancements. It is an ideal refrigerant for modern HVAC applications, contributing to both comfort and sustainability. As the industry continues to evolve, R410A remains a pivotal element in the quest for responsible and efficient refrigeration solutions.