73

PRECAUTIONS FOR SAFETY

WARNING

WARNINGS ABOUT INSTALLATION

Make sure to ask the qualified installation professional in electric work to install the weekly timer for air conditioner.

If the weekly timer for air conditioner is inappropriate installed by yourself, it may cause water leak, electric shock, fire, and so on.

WARNINGS ABOUT OPERATION

When you notice something abnormal with the air conditioner (smells like something scorching, poor cooling, etc.), immedi- ately turn off the main switch, the circuit breaker, from the mains to stop the air conditioner, and contact the dealer.

If the air conditioner is continuously operated with something abnormal, it may cause machine failure, electric shock, fire, and so on.

WARNINGS ABOUT MOVEMENT AND REPAIR

Do not move or repair any unit by yourself.

 

Since there is high voltage inside the unit, you may get

 

electric shock when removing the cover and main unit.

Whenever the air conditioner needs repair, make sure to ask

 

the dealer to do it.

 

If it is repaired imperfectly, it may cause electric shock or fire.

When moving the air conditioner for re-installing at another

NAME AND OPERATION OF EACH PART

 

 

 

SuMoTuWeTh Fr Sa

 

 

 

PROGRAM1

 

 

 

 

 

 

PROGRAM2

 

ERROR

 

 

 

 

 

 

 

 

 

1

PROGRAM3

 

 

 

4

 

WEEKLY TIMER

 

 

 

 

2

PROGRAM

DAY

SET

CANCEL

6

5

3

 

HH MM

CLEAR

CHECK

7

 

 

 

 

8

 

 

 

 

10,11

 

 

 

SuMoTuWeTh Fr Sa

 

 

9

PROGRAM1

 

 

 

12

PROGRAM2

 

ERROR

 

 

 

 

 

 

 

PROGRAM3

 

 

 

 

 

13

place, ask the dealer to do it.

If it is imperfectly installed, it may cause electric shock or fire.

CAUTION

CAUTIONS ABOUT OPERATION

Carefully read this manual before starting the weekly timer for air conditioner.

There are many important things to keep in mind for daily operation.

Do not use this weekly timer for air conditioner for special purpose such as preserving food, precision instruments, art objects, breeding animals, growing potted plants, etc.

Do not touch any switches with wet finger, otherwise you may get an electric shock.

If the air conditioner was not be used for a considerably long time, turn off the main switch or the circuit breaker, for safety. Disconnect from the power supply prevents the unit from lightning and power supply surge.

Prevent any liquid from falling into the weekly timer. Do not spill juice, water or any kind of liquid.

1 Day select button

The day of the week is selected.

Each pushing, mark moves in order of Sunday Monday Tuesday Wednesday Thursday Friday Saturday.

2 Program button

This button is used to set up the contents of the program operation.

3 Hour/Minute button

This button is used to set the present time and ON/OFF time.

4 Timer set button

This button is used to set the day of the week, hour, minute, holiday, and ON/ OFF time.

5 Cancel button

This button is used to cancel as the holiday.

6 Check button

This button is used to confirm the contents of the setting items.

7 Cancel button

This button is used to cancel the setting items.

8 Display of the present day of the week ( mark)

9 ON/OFF time display

ON/OFF time of the timer operation is displays.

10 Operation reserve indication ( mark)

The day of the week when the program operation has been set is displayed.

11 Holiday setting indication ( mark)

The holiday is displayed (Cancel as holiday)

12 Setting error display

13 Present time display

Displays the present time displayed with 24-hours notation.

Page 73
Image 73
Toshiba R410A Day select button, Program button, Hour/Minute button, Timer set button, Cancel button, Check button

R410A specifications

Toshiba R410A is a highly regarded refrigerant known for its efficiency and environmental benefits. This hydrofluorocarbon (HFC) mixture is widely used in various air conditioning and refrigeration applications due to its excellent thermodynamic properties. One of the standout features of R410A is its superior energy efficiency, which contributes to lower energy consumption and reduced CO2 emissions in HVAC systems.

One significant advantage of R410A over older refrigerants, such as R22, is its lower ozone depletion potential (ODP). R410A has an ODP of zero, making it a more environmentally friendly choice. This characteristic aligns with global initiatives aimed at protecting the ozone layer and promoting sustainable practices. The shift to R410A has been supported by government regulations in many countries, phasing out older, more harmful refrigerants.

Toshiba has incorporated advanced technologies in its R410A compatible products, enhancing performance and reliability. Among these technologies is the inverter technology that allows the compressor to operate at variable speeds. This functionality leads to improved temperature regulation, reduced noise levels, and further energy savings. Inverter systems provide precise control over the cooling and heating processes, allowing for a comfortable indoor environment while minimizing wastage of energy.

R410A also exhibits excellent heat transfer properties, which boosts cooling capacity. This feature makes it suitable for large-scale HVAC systems, including commercial and industrial applications. Its high-pressure characteristics enable the design of more compact and efficient components, allowing for smaller units and easier installation.

Furthermore, Toshiba's dedication to technological innovation is visible in its commitment to research and development. The company continuously strives to optimize systems that utilize R410A, focusing on reliability and longevity. This includes improved compressor designs, enhanced heat exchangers, and the integration of smart controls that adapt to the varying load conditions in real-time.

In terms of safety, R410A is classified as non-toxic and non-flammable under normal conditions, making it a safe choice for use in residential and commercial settings. However, it is important to note that R410A operates at higher pressures compared to traditional refrigerants, necessitating proper equipment design and handling procedures.

In conclusion, Toshiba R410A stands out in the market for its energy efficiency, environmental safety, and technological advancements. It is an ideal refrigerant for modern HVAC applications, contributing to both comfort and sustainability. As the industry continues to evolve, R410A remains a pivotal element in the quest for responsible and efficient refrigeration solutions.