Toshiba R410A service manual Installation Place, Necessary Space for Installation

Models: R410A

1 88
Download 88 pages 10.91 Kb
Page 21
Image 21
Manual background

Installation Place

A place which provides a specified space around the outdoor unit.

A place where the operation noise and discharged air are not given to your neighbors.

A place that is not exposed to a strong wind.

A place that does not block a passage.

When the outdoor unit is installed in an elevated position, be sure to secure its feet.

There must be sufficient space for carrying in the unit.

A place where the drain water does not make any problem.

CAUTION

1.Install the outdoor unit at a place where dis- charge air is not blocked.

2.When an outdoor unit is installed in a place that is always exposed to a strong wind like a coast or on a high storey of a building, secure a normal fan operation by using a duct or a wind shield.

3.When installing the outdoor unit in a place that is constantly exposed to a strong wind such as the upper stairs or rooftop of a building, apply the windproof measures referring to the following examples.

1)Install the unit so that its discharge port faces to the wall of the building. Keep a distance 500 mm or more between the unit and the

wall surface.

2)Supposing the wind direction during the operation season of the air conditioner, install the unit so that the discharge port is set at right angle to the wind direction.

Strong wind

Strong wind

4.Installation in the following places may result in some troubles. Do not install the unit in such places below.

A place full of machine oil.

A place full of sulphuric gas.

A place where high-frequency radio waves are likely to be generated as from audio quipment, welders, and medical equipment.

Necessary Space for Installation

Obstacle at rear side

<Upper side is free>

1. Single unit installation

150 or more

2. Obstacles at both right and left sides.

200 ormore

obstacle should be

 

The height of the

 

lower than the height

 

of the outdoor unit.

150

300

or more

or more

3. Serial installation of two or more units

Manual backgroundManual backgroundManual backgroundManual backgroundManual background200 or more

150

300

300

300

or more

or more

or more

or more

The height of the obstacle should be lower than the height of the outdoor unit.

<Obstacle also at the upper side>

500 ormore

150

or more

 

Obstacle at front side

<Upper side is free>

1.

Single unitIn installation

 

500 moreor

 

 

 

 

 

 

 

2.

Serial installation of two or more units

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1000 or more

21

Page 21
Image 21
Toshiba R410A Installation Place, Necessary Space for Installation, Obstacle at rear side <Upper side is free>