Concealed Duct type

Zeolite-3G Deodorant Filter

Installation Manual

 

Model: TCB-FPC11BE

 

TCB-FPC21BE

 

TCB-FPC31BE

 

TCB-FPC41BE

NOTES

Specifications

Deodorant filter

Model

TCB-FPC11BE

TCB-FPC21BE

TCB-FPC31BE

TCB-FPC41BE

 

 

 

 

 

 

Conformed air conditioner model name

561BT

 

801BT

1101 to 1401BT

 

 

 

 

 

 

 

Quantity

 

1

1

 

2

2

 

 

 

 

 

 

 

Initial deodorant performance

 

 

 

70%

 

 

 

 

 

 

Deodorant durable performance

 

Approx. 12 months

 

 

 

 

 

 

 

 

85

Do not unpack the filter until you use it.

(Otherwise, life of the Zeolite-3G deodorant filter is shortened.)

Keep this Manual with Owner’s Manual of the indoor unit.

Safety Cautions

Before installation work, read thoroughly this “Safety Cautions” to install the air conditioner correctly.

This “Safety Cautions” describes the important contents concerned to the safety. Be sure to keep in mind these items. Symbols and meanings are as described below.

WARNING

Indicates “User may be dead or seriously injured (*1) if it is incorrectly used.”

 

 

CAUTION

Indicates “It is assumed that user may be injured (*2) or property damage (*3) may

occur if it is incorrectly used.”

 

 

*1: “Serious injury” means a disease which has an after-effect or requires hospitalization or long-term going to the

hospital for treatment, such as loss of sight, burn (by high temperature or low temperature), electric shock, fracture, poisoning, etc.

*2: “Injury” means hurt, burn, electric shock, etc. which does not require hospitalization or long-term going to the hospital for treatment.

*3: “Property damage” means enlarged damage concerned to house, household effects, domestic animal, pet, etc.

Explanation of picture symbols

indicates prohibition (prohibited action).

The concrete prohibited action is indicated with picture or sentence in or near the picture symbol.

indicates that the forced instructed action (Act necessarily).

The concrete instructed action is indicated with picture or sentence in or near the picture symbol.

indicates an item with care.

The concrete item to be cautioned is indicated with picture or sentence in or near the picture symbol.

Installation of filter sold separately

1 Remove the air filter, and install a filter sold separately to the suction port.

Push the filter sold separately completely up to the end.

Check that the rear side is hanged to the hook.

2 Install the air filter

Be sure to fix the air filter with clamps in order to prevent falling.

(Clamps are attached to the indoor unit.)

Maintenance of filter sold separately

• Clean the filter sold separately once per 6 months.

1 Take out the filter sold separately in the reverse order of “Installation of filter sold separately”.

2 Cleaning of the filter sold separately

Sweep away the dust of the filter sold separately by hitting lightly and dry it in the sunlight for 6 hours or more.

In case of wash the filter sold separately with water

Put the filter sold separately horizontally on a place where is exposed to the sunlight, and then wash it with running water such as shower.

After then, leave it as it is until it will dry. In this time, also dry it in the sunlight for 6 hours or more.

3 Install the air filter.

Filter sold separately

Indoor unit

Hook

 

Filter sold separately

Zeolite-3G deodorant filter

Air filter

NOTE

WARNING

Do not put a plastic bag including filter on a place where hands of a small child can reach.

If the child puts the bag on his head,

it may seal his mouth or nose resulting in choke of death.

CAUTION

Install the suction grille surely to the main unit. If an incomplete installation is

performed, falling of the suction grille causes an injury.

Based upon “Installation of filter sold separately”, install the filter.

If treating the filter as it gets wet, it may be damaged.

FPBE-E

Page 85
Image 85
Toshiba R410A Zeolite-3G Deodorant Filter, Specifications, Safety Cautions, Installation of filter sold separately

R410A specifications

Toshiba R410A is a highly regarded refrigerant known for its efficiency and environmental benefits. This hydrofluorocarbon (HFC) mixture is widely used in various air conditioning and refrigeration applications due to its excellent thermodynamic properties. One of the standout features of R410A is its superior energy efficiency, which contributes to lower energy consumption and reduced CO2 emissions in HVAC systems.

One significant advantage of R410A over older refrigerants, such as R22, is its lower ozone depletion potential (ODP). R410A has an ODP of zero, making it a more environmentally friendly choice. This characteristic aligns with global initiatives aimed at protecting the ozone layer and promoting sustainable practices. The shift to R410A has been supported by government regulations in many countries, phasing out older, more harmful refrigerants.

Toshiba has incorporated advanced technologies in its R410A compatible products, enhancing performance and reliability. Among these technologies is the inverter technology that allows the compressor to operate at variable speeds. This functionality leads to improved temperature regulation, reduced noise levels, and further energy savings. Inverter systems provide precise control over the cooling and heating processes, allowing for a comfortable indoor environment while minimizing wastage of energy.

R410A also exhibits excellent heat transfer properties, which boosts cooling capacity. This feature makes it suitable for large-scale HVAC systems, including commercial and industrial applications. Its high-pressure characteristics enable the design of more compact and efficient components, allowing for smaller units and easier installation.

Furthermore, Toshiba's dedication to technological innovation is visible in its commitment to research and development. The company continuously strives to optimize systems that utilize R410A, focusing on reliability and longevity. This includes improved compressor designs, enhanced heat exchangers, and the integration of smart controls that adapt to the varying load conditions in real-time.

In terms of safety, R410A is classified as non-toxic and non-flammable under normal conditions, making it a safe choice for use in residential and commercial settings. However, it is important to note that R410A operates at higher pressures compared to traditional refrigerants, necessitating proper equipment design and handling procedures.

In conclusion, Toshiba R410A stands out in the market for its energy efficiency, environmental safety, and technological advancements. It is an ideal refrigerant for modern HVAC applications, contributing to both comfort and sustainability. As the industry continues to evolve, R410A remains a pivotal element in the quest for responsible and efficient refrigeration solutions.