Yeoman YM-CL8HB manual Fitting and Removal of the Baffle, Removal of Riddling Mechanism

Page 24

INSTALLATION INSTRUCTIONS

3.FITTING AND REMOVAL OF THE BAFFLE

No tools are required.

3.1To maintain efficient combustion the appliance is fitted with a baffle system that allows for secondary combustion (see Diagram 4).

4

PR8885

3.2First remove the log guard from the stove to give access to the firebox.

3.3Use both hands to lift the baffle vertically and slide to one side (see Diagram 5). Always wear gloves when handling appliance parts.

5

AR2404

Using both hands rotate the baffle to remove from the firebox through the door opening.

3.4To replace the baffle repeat the above steps in reverse, ensuring the baffle fits over the supports on the sides of the interior (see Diagram 6).

6

Front support

Rear support

AR2405

Ensure baffle sits

 

 

 

 

 

 

on front supports

Baffle In Place

AR2406

 

 

 

 

 

 

 

 

Do not modify the baffle.

4.REMOVAL OF RIDDLING MECHANISM

4.1The Multi-fuel grate can be removed for cleaning to maintain good working condition.

To remove the grate:

Remove the baffle (see Section 3).

Remove the log guard to enable access (see Section 2).

Remove the ashpan.

Remove the riddling bars (see Diagram 7).

FOR CLARITY, THE FOLLOWING DIAGRAMS DO NOT INCLUDE ILLUSTRATIONS OF THE DOORS.

24

Image 24
Contents Yeoman CL YM-CL8HBContents Appliance Commissioning Checklist Installation EngineerRetailer appliance was purchased from Essential Information Must be completedUser Instructions General PointsSerial Number ThermostatHeating System controls Do not place tool on hot surfaces e.g. top of stoveUse a protected gloved hand to operate Using the Appliance for the First Time CondensationNormal Running Seasonal USELighting the Appliance Solid fuelRunning The appliance Burning woodDo not load above the log guard or base of baffle Refuelling Thermostat OperationBurning tips ASH Removal Wood burning tray Extended burningOVER-FIRING Over-firing can cause permanent damage to the applianceGeneral Cleaning Cleaning GlassChimney fire Chimney SweepingTroubleshooting tips Care of stove Seasonal useAll or some of the radiators do not get hot Open up the airwash to makeTECHNICAL SPECIFICATION Standard FeaturesBoiler Output Chart YeomanYeoman Dimensions All dimensions are in mm 25.4mm =Cast Top Plate Incl. feet @ 6mm on underside 563 572 363 105 478 153/6 449 441 225 430 224 317Site Requirements Flue or ChimneyMax. Draught = 2.0mm Wg Min. Draught = 1.0mm Wg U.K Flue PlateHearth Dimensions Flue Outlet PositionsWalls Next to a Hearth Requirement for the walls80mm PRE-INSTALLATION Checks FlueWithout Liner System 150 Flue / Chimney SizeVentilation ModelMm² 4400 Additional Ventilation Changes to Document J, England & Wales, from 01/10/2010Installation Instructions Installing the ApplianceTop flue pipe installation Legal requirementsSecure with self tapping screw Seal the connecting joints Rear flue pipe installationDo not use a 90˚elbow to make this connection To chimney connection as detailed in building regulationsFitting and Removal of the Baffle Removal of Riddling MechanismEnsure baffle sits On front supports Baffle In Place Do not modify the baffleRemove Rear Bar see Diagram Lift bars to removeUnscrew the boss Replace in reverse orderHearth Fixing Cast TOPFixing holes Hearth mounts Top Flue Rear FlueCentral Heating System Pipe work Diagrams PumpElectrical Supply Conventional Pipe work systemsFeed Expansion Cistern Link UP Systems Controls GeneralCommissioning CommissioningInstructions for Use Give the copy of the Instructions to the customerAnnual Service Removal of the LOG Guard Fitting and Removal of BaffleFitting a NEW Door Glass Do not use appliance without the log guard in positionFitting a new door seal Do not over tighten the clamp as this could break the glassMid door Rope seal E Joint Adjusting Door Catch & Hinges To adjust the door hinge plate assemblyHetas Approved Chimney Sweeps Spare Parts List Cast Door Service Records