Yeoman YM-CL8HB manual Secure with self tapping screw Seal the connecting joints

Page 23

INSTALLATION INSTRUCTIONS

PR8009

The flue must be installed in accordance with manufacturers instructions.

Flue Pipe 915mm (3ft)

Size

Stovax Part No.

6"

4602

Self tapping screw at rear

Seal flue collar with Fire Cement

—Secure with self tapping screw.

—Seal the connecting joints.

Do not use a 90˚elbow to make this connection.

The flue must be installed in accordance with manufacturers instructions.

Seal Collar with Fire Cement

Self tapping screw

 

 

Tee

 

Size

Stovax Part No.

 

6"

4616

 

 

 

Cap

PR8735

To chimney connection as detailed in building regulations

PR8733

600mm min

Elbow with access cover

Size Stovax Part No.

6" 4612

600mm min

1000mm max unsupported

To chimney connection as detailed in building regulations

Elbow with access cover

Size Stovax Part No.

6" 4612

Flue Pipe 915mm (3ft)

Size Stovax Part No.

6" 4602

1000mm max unsupported

Flue Pipe 915mm (3ft)

Size

Stovax Part No.

6"

4602

 

 

PR8736

2. REMOVAL OF THE LOG GUARD

2.1 To remove the Log guard:

—Lift Log Guard clear of the supporting brackets.

PR8734

1.3Rear flue pipe installation:

—Insert a tee into the flue collar. The tee piece is used as cleaning access.

—Lift appliance into position, taking care not to damage the hearth finish.

—Level using adjustable bolts.

—Connect tee to the chimney using flue pipe.

—Rotate to clear the sides of the door opening.

Do not use appliance without the log guard in position.

23

Image 23
Contents YM-CL8HB Yeoman CLContents Essential Information Must be completed Appliance Commissioning ChecklistInstallation Engineer Retailer appliance was purchased fromThermostat User InstructionsGeneral Points Serial NumberUse a protected gloved hand to operate Heating System controlsDo not place tool on hot surfaces e.g. top of stove Seasonal USE Using the Appliance for the First TimeCondensation Normal RunningSolid fuel Lighting the ApplianceDo not load above the log guard or base of baffle Running The applianceBurning wood Burning tips RefuellingThermostat Operation ASH Removal Over-firing can cause permanent damage to the appliance Wood burning trayExtended burning OVER-FIRINGChimney Sweeping General CleaningCleaning Glass Chimney fireCare of stove Seasonal use Troubleshooting tipsOpen up the airwash to make All or some of the radiators do not get hotYeoman TECHNICAL SPECIFICATIONStandard Features Boiler Output Chart563 572 363 105 478 153/6 449 441 225 430 224 317 Yeoman DimensionsAll dimensions are in mm 25.4mm = Cast Top Plate Incl. feet @ 6mm on undersideFlue Plate Site RequirementsFlue or Chimney Max. Draught = 2.0mm Wg Min. Draught = 1.0mm Wg U.KFlue Outlet Positions Hearth Dimensions80mm Walls Next to a HearthRequirement for the walls Flue / Chimney Size PRE-INSTALLATION ChecksFlue Without Liner System 150Changes to Document J, England & Wales, from 01/10/2010 VentilationModel Mm² 4400 Additional VentilationLegal requirements Installation InstructionsInstalling the Appliance Top flue pipe installationTo chimney connection as detailed in building regulations Secure with self tapping screw Seal the connecting jointsRear flue pipe installation Do not use a 90˚elbow to make this connectionDo not modify the baffle Fitting and Removal of the BaffleRemoval of Riddling Mechanism Ensure baffle sits On front supports Baffle In PlaceReplace in reverse order Remove Rear Bar see DiagramLift bars to remove Unscrew the bossTop Flue Rear Flue Hearth FixingCast TOP Fixing holes Hearth mountsCentral Heating System Conventional Pipe work systems Pipe work DiagramsPump Electrical SupplyFeed Expansion Cistern Controls General Link UP SystemsGive the copy of the Instructions to the customer CommissioningCommissioning Instructions for UseAnnual Service Do not use appliance without the log guard in position Removal of the LOG GuardFitting and Removal of Baffle Fitting a NEW Door GlassMid door Rope seal E Joint Fitting a new door sealDo not over tighten the clamp as this could break the glass Hetas Approved Chimney Sweeps Adjusting Door Catch & HingesTo adjust the door hinge plate assembly Spare Parts List Cast Door Service Records