SITE REQUIREMENTS
WALLS NEXT TO A HEARTH
Solid,
H
150mm
minimum
C
Thickness W
C
150mm
minimum
|
|
|
| PR8731 |
|
|
|
|
|
|
|
|
|
|
| Position of Appliance & Hearth in relation to walls | Requirement for the walls | ||
|
|
|
|
|
| Distance of hearth from wall | Distance of Appliance to wall | Min thickness of Wall | Min height of wall |
| 'C' |
| 'W' | 'H' |
|
|
|
|
|
| 0mm | 0mm - 50mm | 200mm | Height of appliance + 300mm |
|
|
|
| Or |
|
|
|
| |
|
|
|
| 1200mm from the hearth (take largest |
| 0mm | 51mm - 300mm | 75mm | dimension) |
|
|
|
|
|
| 0 - 150mm | 150mm + | 75mm | 1200mm |
|
|
|
|
|
| 150mm + | 300mm + | No Minimum Requirement | |
|
|
|
|
|
Suitable clearance should be allowed around the stove to enable the correct fitting and maintenance of the appliance. Any clearances should be confirmed by making a site survey and a physical check of wall thickness and dimensions.
80mm
Note:
When installing a
PR8589