Net Safety Monitoring Inc.
Appendix C: SPECIFICATIONS
SENSOR SPECIFICATIONS
| SENSOR ELEMENT |
| Oxygen O2 (ST1400) |
|
|
|
|
|
| Operating Temperature Range |
|
|
| ||||
| Range of Detection |
| 0 to 25% |
|
|
|
|
|
| Response Time |
| <15 seconds to T95 |
|
|
|
|
|
| Span Drift |
| <5% of signal loss / year |
|
|
|
|
|
| Enclosure Material |
| Anodized / powder coated aluminum (optional stainless steel) |
|
| |||
| Certifications |
| CSA and NRTL/C certified for hazardous locations. Class I, Division 1, Groups C and D. |
| ||||
|
| IEC Rating Ex d IIB T6 NEMA 3R (Class 1, Zone 1, Grp IIB T6) |
|
| ||||
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
| Weight |
| 0.5 Kg (1.0 lb) |
|
|
|
|
|
CONTROLLER SPECIFICATION |
|
|
|
|
| |||
|
|
|
|
|
|
| ||
| MILLENNIUM | ANALOG |
| ANALOG/RELAY |
| ANALOG/DIGITAL | ||
|
|
|
|
|
|
|
|
|
| Operating Temperature Range |
|
|
|
|
| ||
|
|
|
|
|
|
| ||
| Power Consumption @ 24 V dc | Nom 68 mA / 1.63 W |
| Nom 75 mA / 2.0 W |
| Nominal 125 mA/3.01 W | ||
|
| Max 90 mA / 2.16 W |
| Max 108 mA / 2.6 W |
| Maximum 155mA/3.73 W | ||
|
|
|
|
|
|
|
|
|
| Humidity Range |
|
| 0 to 99% relative humidity, |
|
| ||
|
|
|
|
|
|
|
| |
| Operating Voltage Range |
|
|
| 10.5 to 32.0 V dc |
|
| |
|
|
|
| |||||
| Enclosure Material |
| Powder coated Copper Free Cast Aluminum (optional stainless steel) | |||||
|
|
| ||||||
| Certifications | CSA and NRTL/C certified for hazardous locations. Class I, Division 1, Groups B, C and D. NEMA 4X. | ||||||
|
| IEC Rating Ex d IIB+H2 T5 |
|
|
|
|
| |
|
| Note: With any Type 4 enclosure (electronics | ||||||
|
| sensor and electronics), CSA and NRTL/C certified for hazardous locations, Class 1, Division 2, Groups A, B, C and D. | ||||||
|
|
|
|
|
|
|
| |
| Weight | 3.2 Kg (7.0 lb) |
|
|
|
|
| |
|
|
| ||||||
| Outputs | - 4 to 20 mA - Into a maximum loop impedance of 800 Ohms at 32 V dc or 150 Ohms at 10.5 V dc. Isolated or | ||||||
|
| - Premium version - Form C contacts rated 5 Amps at 30 V dc / 250 V ac. Selectable energized / | ||||||
|
| and high alarms. Fault relay is factory set as energized, |
|
| ||||
|
| Low Power Version - Form A contacts rated.2.5 Amps at 60 V ac/dc. Selectable energized / | ||||||
|
| high alarms. Fault relay is factory set as energized, |
|
| ||||
|
| - Digital RS 485 Modbus RTU Protocol |
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
22 |