Emerson Process Management 2051CF manual Product Certifications, Approved Manufacturing Locations

Page 16

Quick Installation Guide

Rosemount 2051

00825-0100-4101, Rev EA June 2010

2051 Safety Failure Values

Safety accuracy: 2%(1)

Safety response time- 1.5 sec

Product Life

50 years – based on worst case component wear-out mechanisms – not based on wear-out process wetted materials

PRODUCT CERTIFICATIONS

Approved Manufacturing Locations

Emerson Process Management - Rosemount Inc. — Chanhassen, Minnesota, USA Emerson Process Management — Wessling, Germany

Emerson Process Management Asia Pacific Private Limited — Singapore Emerson Process Management — Beijing, China

Emerson Process Management — Daman, India

European Directive Information

The EC declaration of conformity can be found on page 20. The most recent revision can be found at www.emersonprocess.com.

Ordinary Location Certification for Factory Mutual

As standard, the transmitter has been examined and tested to determine that the design meets basic electrical, mechanical, and fire protection requirements by FM, a nationally recognized testing laboratory (NRTL) as accredited by the Federal Occupational Safety and Health Administration (OSHA).

(1)A 2% variation of the transmitter mA output is allowed before a safety trip. Trip values in the DCS or Safety Logic Solver should be derated by 2%.

16

Image 16
Contents Quick Installation Guide Rosemount 2051CF Series Flowmeter TransmitterExplosions could result in death or serious injury Process leaks may cause harm or result in deathElectrical shock can result in death or serious injury Conduit/Cable EntriesApplications Mount the TransmitterFlow Optional Mounting Brackets Bolting Considerations Common Transmitter AssembliesRings with Flange Adapters Flange AdapterRing Ptfe BasedInline Gage Transmitter Orientation Consider Housing RotationSET the Jumpers MA Hart Connect the Wiring and Power RL ≥ 250ΩWiring Power Supply for 4-20 mA Hart Power Supply for 1-5 Vdc Hart Low PowerVerify Configuration Function MA HartUsing the Field Communicator Using the Transmitter Zero Adjustment ButtonsTrim the Transmitter Zero TrimInstallation Safety Instrumented SystemsConfiguration Operation and Maintenance ReferenceSafety Failure Values Product CertificationsApproved Manufacturing Locations European Directive InformationHart Protocol Hazardous Locations CertificationsNorth American Certifications European CertificationsRosemount IECEx Certifications Inmetro Certifications Tiis CertificationsCCoE Certifications Combinations of Certifications E1, I1, N1, and ND combinationE4 and I4 combination E5 and I5 combinationRosemount Rosemount Rosemount