Emerson Process Management 2051CF manual Hart Protocol, Hazardous Locations Certifications

Page 17

Quick Installation Guide

00825-0100-4101, Rev EA June 2010

Rosemount 2051

HART Protocol

Hazardous Locations Certifications

North American Certifications

FM Approvals

E5 Explosion-Proof for Class I, Division 1, Groups B, C, and D. Dust-Ignition-Proof for Class II, Division 1, Groups E, F, and G. Dust-Ignition-Proof for Class III, Division 1.

T5 (Ta = 85 °C), Factory Sealed, Enclosure Type 4X

I5 Intrinsically Safe for use in Class I, Division 1, Groups A, B, C, and D; Class II, Division 1, Groups E, F, and G; Class III, Division 1 when connected per Rosemount drawing 02051-1009; Non-incendive for Class I, Division 2, Groups A, B, C, and D. Temperature Code:T4 (Ta = 70 °C),

Enclosure Type 4X

For input parameters see control drawing 02051-1009.

Canadian Standards Association (CSA)

All CSA hazardous approved transmitters are certified per ANSI/ISA 12.27.01-2003.

E6 Explosion-Proof for Class I, Division 1, Groups B, C, and D. Dust-Ignition-Proof for Class II and Class III, Division 1, Groups E, F, and G. Suitable for Class I, Division 2 Groups A, B, C, and D for indoor and outdoor hazardous locations. Class I Zone 1 Ex d IIC T5. Enclosure type 4X, factory sealed. Single Seal.

I6 Intrinsically safe approval. Intrinsically safe for Class I, Division 1, Groups A, B, C, and D when connected in accordance with Rosemount drawing 02051-1008. Temperature Code T3C. Class I Zone 1 Ex ia IIC T3C. Single Seal.

European Certifications

I1 ATEX Intrinsic Safety

Certification No. Baseefa08ATEX0129X II 1 G Ex ia IIC T4 (–60 Ta +70 °C)

IP66 IP68 1180

Table 2. Input Parameters for 4-20 mA

Ui = 30V

Ii = 200 mA

Pi = 1.0W

Ci = 0.012 µF

Special Conditions for Safe Use (X):

When the optional transient protection terminal block is installed, the apparatus is not capable of withstanding the 500V insulation test required by Clause 6.3.12 of EN60079-11. This must be taken into account when installing the apparatus.

17

Image 17
Contents Rosemount 2051CF Series Flowmeter Transmitter Quick Installation GuideProcess leaks may cause harm or result in death Explosions could result in death or serious injuryElectrical shock can result in death or serious injury Conduit/Cable EntriesFlow Mount the TransmitterApplications Optional Mounting Brackets Common Transmitter Assemblies Bolting ConsiderationsFlange Adapter Rings with Flange AdaptersRing Ptfe BasedSET the Jumpers Consider Housing RotationInline Gage Transmitter Orientation MA Hart RL ≥ 250Ω Connect the Wiring and PowerWiring Power Supply for 1-5 Vdc Hart Low Power Power Supply for 4-20 mA HartFunction MA Hart Verify ConfigurationUsing the Transmitter Zero Adjustment Buttons Using the Field CommunicatorTrim the Transmitter Zero TrimConfiguration Safety Instrumented SystemsInstallation Reference Operation and MaintenanceProduct Certifications Safety Failure ValuesApproved Manufacturing Locations European Directive InformationHazardous Locations Certifications Hart ProtocolNorth American Certifications European CertificationsRosemount IECEx Certifications CCoE Certifications Tiis CertificationsInmetro Certifications E1, I1, N1, and ND combination Combinations of CertificationsE4 and I4 combination E5 and I5 combinationRosemount Rosemount Rosemount