Quick Installation Guide
Rosemount 2051
IECEx Certifications
I7 IECEx Intrinsic Safety Certification No. IECExBAS08.0045X Ex ia IIC T4
1180
Table 3. Input Parameters
Ui = 30V
Ii = 200 mA
Pi = 1.0W
Ci = 0.012 µF
Special Conditions for Safe Use (X):
When the optional transient protection terminal block is installed, the apparatus is not capable of withstanding the 500V insulation test required by Clause 6.3.12 of
E7 IECEx
Certification No. IECExKEM08.0024X Ex d IIC T6
1180
Vmax = 42.4 V dc
Special Conditions for Safe Use (X):
1.Appropriate ex d blanking plugs, cable glands, and wiring needs to be suitable for a temperature of 90 °C.
2.This device contains a thin wall diaphragm. Installation, maintenance and use shall take into account the environmental conditions to which the diaphragm will be subjected. The manufacturer’s instructions for maintenance shall be followed in detail to assure safety during its expected lifetime.
3.The 2051 does not comply with the requirements of IEC
N7 IECEx Type n
Certification No. IECExBAS08.0046X
Ex nAnL IIC T4
Ui = 42.4 Vdc max
Special Conditions for Safe Use (X):
When the optional transient protection terminal block is installed, the apparatus is not capable of withstanding a 500V r.m.s. test to case. This must be taken into account on any installation in which it is used, for example by assuring that the supply to the apparatus is galvanically isolated.