CDA 4Q4 manual Technical Information for the Installer

Page 20

TECHNICAL INFORMATION FOR THE INSTALLER

In order to install the cooktop into the kitchen fixture, a hole with the dimensions shown in fig. 19 has to be made, bearing in mind the following:

Within the unit, between the bottom of the cooktop and the upper surface of a shelf there must be a clearance of at least 30 mm.

It is absolutely essential that you place a separator between the base of the cooktop and the built-in unit or the oven;

The cooktop must be kept no less than 200 mm away from any side wall (fig. 18).

There must be a distance of at least 60 mm between the back side of the cut-out and the back of the countertop.

There must be a distance of at least 650 mm between the hob and any wall cup- board or extractor hood positioned immediately above (see fig. 18).

If the hob is installed over a built-in oven, the built-in oven shall be provided with cooling fan.

The two appliances shall be connected to the gas/electric supply with independent connections.

Figure 18

20

 

450 mm

 

200

mm

min

 

 

 

650 mm

500

mm

 

Image 20
Contents 4Q4 Four Burner Gas Hob Declaration of CE conformity Contents Before Using for the First Time Important Safeguards & Recommendations Features Cooking Points Control PanelUse of the Hob GAS BurnersLighting the Burners Choice of Burner Max 36 cmCorrect USE of TRIPLE-RING Burner Page Glass Surface Cleaning and MaintenanceGeneral Tips Control Knobs Enamelled PartsGAS Taps Burners and Grids Important WarningIt is very important to check that Ignitor S Flame failure probe T Tips For Installation Location Technical Information for the Installer 585 Fastening the Cooktop Ventilation requirements Installation & Service Regulations United Kingdom Gas supply requirementsInstallation to Natural GAS Gas ConnectionGAS Connector Connection to the GAS SupplyConversion to Natural Gas or LPG Replacing the Burner InjectorsTable for the choice of the Injectors Cat II 2H3+Minimum Burner Setting Adjustment Lubrication of the gas tapsElectrical Connection Section of the Supply Cable Type H05V2V2-F Appliance servicing Guarantee Limit of CoverPage Page Gas on glass cooktops