CDA 4Q4 manual Ventilation requirements

Page 23

Ventilation requirements

The appliance should be installed into a room or space with an air supply in accor- dance with BS 5440-2: 2000.

For rooms with a volume of less than 5 m3 - permanent ventilation of 100 cm2 free area will be required.

For rooms with a volume of between 5 m3 and 10 m3 a permanent ventilation of 50 cm2 free area will be required unless the room has a door which opens directly to the outside air in which case no permanent ventilation is required.

For rooms with a volume greater than 10 m3 - no permanent ventilation is required.

NB. Regardless of room size, all rooms containing the appliance must have direct access to the outside air via an openable window or equivalent.

Where there are other fuel burning appliances in the same room, BS 5440-2: 2000 should be consulted to determine the correct amount of free area ventilation require- ments.

The above requirements allow also for use of a gas oven and grill but if there are other gas burning appliances in the same room, consult a qualified engineer.

23

Image 23
Contents 4Q4 Four Burner Gas Hob Declaration of CE conformity Contents Before Using for the First Time Important Safeguards & Recommendations Features Control Panel Cooking PointsGAS Burners Use of the HobLighting the Burners Max 36 cm Choice of BurnerCorrect USE of TRIPLE-RING Burner Page Glass Surface Cleaning and MaintenanceGeneral Tips Control Knobs Enamelled PartsGAS Taps Important Warning Burners and GridsIt is very important to check that Ignitor S Flame failure probe T Tips For Installation Location Technical Information for the Installer 585 Fastening the Cooktop Ventilation requirements Gas supply requirements Installation & Service Regulations United KingdomGas Connection Installation to Natural GASConnection to the GAS Supply GAS ConnectorReplacing the Burner Injectors Conversion to Natural Gas or LPGCat II 2H3+ Table for the choice of the InjectorsLubrication of the gas taps Minimum Burner Setting AdjustmentElectrical Connection Section of the Supply Cable Type H05V2V2-F Appliance servicing Limit of Cover GuaranteePage Page Gas on glass cooktops