CDA 4Q4 manual Conversion to Natural Gas or LPG, Replacing the Burner Injectors

Page 27

Conversion to Natural Gas or LPG

REPLACING THE BURNER INJECTORS

If the NATURAL GAS/LPG conversion kit is not supplied with the appliance this kit can be purchased by contacting the After-Sales Service.

Choose the injectors to be replaced according to the table on next page.

The injector diameter, expressed in hundredths of a millimetre, is marked on the injector body.

To replace the injectors proceed as follows:

Remove the pan supports and the burners covers.

Using a wrench, substitute the nozzle injectors “J” (Figs. 25 - 26) with those most suitable for the kind of gas for which it is to be used.

The burners are made in such a way so as not to require regulation of the primary air.

Figure 25

J

Figure 26

J

27

Image 27
Contents 4Q4 Four Burner Gas Hob Declaration of CE conformity Contents Before Using for the First Time Important Safeguards & Recommendations Features Control Panel Cooking PointsGAS Burners Use of the HobLighting the Burners Max 36 cm Choice of BurnerCorrect USE of TRIPLE-RING Burner Page Cleaning and Maintenance General TipsGlass Surface Enamelled Parts GAS TapsControl Knobs Important Warning Burners and GridsIt is very important to check that Ignitor S Flame failure probe T Tips For Installation Location Technical Information for the Installer 585 Fastening the Cooktop Ventilation requirements Gas supply requirements Installation & Service Regulations United KingdomGas Connection Installation to Natural GASConnection to the GAS Supply GAS ConnectorReplacing the Burner Injectors Conversion to Natural Gas or LPGCat II 2H3+ Table for the choice of the InjectorsLubrication of the gas taps Minimum Burner Setting AdjustmentElectrical Connection Section of the Supply Cable Type H05V2V2-F Appliance servicing Limit of Cover GuaranteePage Page Gas on glass cooktops