Table for the choice of the Injectors

GB

Cat: II 2H3+

NOMINAL

REDUCED

G30/G31

G 20

POWER

POWER

28-30/37 mbar

20 mbar

 

 

 

 

 

 

BURNER

[Hs - kW]

[Hs - kW]

Ø injecteur

Ø injecteur

 

 

 

[1/100 mm]

[1/100 mm]

Auxiliary (A)

1,00

0,30

0,50

0,72 (X)

Semirapid (SR)

1,75

0,45

0,65

0,97 (Z)

Rapid (R)

3,00

0,75

0,85

1,15 (Y)

Triple ring (TR)

3,50

1,50

0,95

1,35 (T)

28

Image 28
Contents 4Q4 Four Burner Gas Hob Declaration of CE conformity Contents Before Using for the First Time Important Safeguards & Recommendations Features Cooking Points Control PanelUse of the Hob GAS BurnersLighting the Burners Choice of Burner Max 36 cmCorrect USE of TRIPLE-RING Burner Page General Tips Cleaning and MaintenanceGlass Surface GAS Taps Enamelled PartsControl Knobs Burners and Grids Important WarningIt is very important to check that Ignitor S Flame failure probe T Tips For Installation Location Technical Information for the Installer 585 Fastening the Cooktop Ventilation requirements Installation & Service Regulations United Kingdom Gas supply requirementsInstallation to Natural GAS Gas ConnectionGAS Connector Connection to the GAS SupplyConversion to Natural Gas or LPG Replacing the Burner InjectorsTable for the choice of the Injectors Cat II 2H3+Minimum Burner Setting Adjustment Lubrication of the gas tapsElectrical Connection Section of the Supply Cable Type H05V2V2-F Appliance servicing Guarantee Limit of CoverPage Page Gas on glass cooktops