Gas Connection

The installation of the gas appliance to Natural Gas or LP Gas must be carried out by a C.O.R.G.I. registered installer. Installers shall take due account of the provisions of the relevant British Standards Code of Practice, the Gas Safety Regulations and the Building Standards (Scotland)(Consolidation) Regulations issued by the Scottish Development Department.

INSTALLATION TO NATURAL GAS

Installation to Natural Gas must conform to the Code of Practice, etc. The supply pressure for Natural Gas is 20 mbar.

The installation must conform to the relevant British Standards.

INSTALLATION TO LP GAS

When operating on Butane gas a supply pressure of 28-30 mbar is required. When using Propane gas a supply pressure of 37 mbar is required.

The installation must conform to the relevant British Standards.

CDA are not legally able to provide any assistance in the installation of gas appliances except to Corgi registered installers. Any Corgi registered fitter requiring help must pro- vide name, address and registration number.

Information supplied will be validated before help is provided.

Warning: Only a C.O.R.G.I. registered installer, also with technical knowledge of electricity should install the appliance. He should observe the Regulations and Codes of Practice governing such installation of gas appliances.

Note: It is recommended that the gas connection to the appliance is installed with a flexible connecting tube made to BS5386.

Notes:

Flexible hoses can be used where the sited ambient temperature of the hose does not exceed 70°C. These hoses must be manufactured in accordance with BS669 part 1 and be of the correct construction for the type of gas being used.

Gas hoses designed for natural gas MUST NOT be used for supplying LPG gas (LPG gas hoses can be identified by a either a red band or stripe on the rubber outer coating of the hose).

The hose should not be crushed or trapped or be in contact with sharp or abrasive edges.

25

Image 25
Contents 4Q4 Four Burner Gas Hob Declaration of CE conformity Contents Before Using for the First Time Important Safeguards & Recommendations Features Control Panel Cooking PointsGAS Burners Use of the HobLighting the Burners Max 36 cm Choice of BurnerCorrect USE of TRIPLE-RING Burner Page General Tips Cleaning and MaintenanceGlass Surface GAS Taps Enamelled PartsControl Knobs Important Warning Burners and GridsIt is very important to check that Ignitor S Flame failure probe T Tips For Installation Location Technical Information for the Installer 585 Fastening the Cooktop Ventilation requirements Gas supply requirements Installation & Service Regulations United KingdomGas Connection Installation to Natural GASConnection to the GAS Supply GAS ConnectorReplacing the Burner Injectors Conversion to Natural Gas or LPGCat II 2H3+ Table for the choice of the InjectorsLubrication of the gas taps Minimum Burner Setting AdjustmentElectrical Connection Section of the Supply Cable Type H05V2V2-F Appliance servicing Limit of Cover GuaranteePage Page Gas on glass cooktops