CDA 4Q4 manual Lubrication of the gas taps, Minimum Burner Setting Adjustment

Page 29

MINIMUM BURNER SETTING ADJUSTMENT

Check whether the flame spreads to all burner ports when the burner is lit with the gas tap set to the minimum position. If some ports do not light, increase the minimum gas rate setting.

Check whether the burner remains lit even when the gas tap is turned quickly from the maximum to the minimum position. If the burner does not remain lit, increase the minimum gas rate setting.

The adjustment is performed with the burner lit, as follows:

Turn the knob to the minimum position.

Remove the knob.

Using a screwdriver turn screw "A" until the flame setting is correct.

Normally for LPG, fully tighten the adjustment screw.

Figure 27

A

Lubrication of the gas taps

The operations must be executed by a qualified technician.

IMPORTANT

All intervention regarding installation maintenance and conversion of the appliance must be fulfilled with original factory parts.

The manufacturer declines any liability resulting from the non-compliance of this obligation.

29

Image 29
Contents 4Q4 Four Burner Gas Hob Declaration of CE conformity Contents Before Using for the First Time Important Safeguards & Recommendations Features Control Panel Cooking PointsGAS Burners Use of the HobLighting the Burners Max 36 cm Choice of BurnerCorrect USE of TRIPLE-RING Burner Page Glass Surface Cleaning and MaintenanceGeneral Tips Control Knobs Enamelled PartsGAS Taps Important Warning Burners and GridsIt is very important to check that Ignitor S Flame failure probe T Tips For Installation Location Technical Information for the Installer 585 Fastening the Cooktop Ventilation requirements Gas supply requirements Installation & Service Regulations United KingdomGas Connection Installation to Natural GASConnection to the GAS Supply GAS ConnectorReplacing the Burner Injectors Conversion to Natural Gas or LPGCat II 2H3+ Table for the choice of the InjectorsLubrication of the gas taps Minimum Burner Setting AdjustmentElectrical Connection Section of the Supply Cable Type H05V2V2-F Appliance servicing Limit of Cover GuaranteePage Page Gas on glass cooktops