MINIMUM BURNER SETTING ADJUSTMENT
Check whether the flame spreads to all burner ports when the burner is lit with the gas tap set to the minimum position. If some ports do not light, increase the minimum gas rate setting.
Check whether the burner remains lit even when the gas tap is turned quickly from the maximum to the minimum position. If the burner does not remain lit, increase the minimum gas rate setting.
The adjustment is performed with the burner lit, as follows:
✓Turn the knob to the minimum position.
✓Remove the knob.
✓Using a screwdriver turn screw "A" until the flame setting is correct.
Normally for LPG, fully tighten the adjustment screw.
Figure 27
A
Lubrication of the gas taps
The operations must be executed by a qualified technician.
IMPORTANT
All intervention regarding installation maintenance and conversion of the appliance must be fulfilled with original factory parts.
The manufacturer declines any liability resulting from the
29