CDA 4Q4 manual GAS Connector, Connection to the GAS Supply

Page 26

GAS CONNECTOR

GB Cat: II 2H3+

The fitting (fig. 23) is made up of:

1 nut “A”

1 elbow fitting “C”

gasket “F”

CONNECTION TO THE GAS SUPPLY

Be careful when flexible pipes are used that they do not come into contact with moving parts.

To maintain the thickness of 3 cm, the hob is fitted with a channel to contain the connection pipe.

The gas inlet union can be turned in the direction required after the elbow fitting “C” and nut “A” connection (figure 23) has been slackened (Fig. 24).

Never put it in the horizontal or vertical position.

Never attempt to turn the elbow “C” without having first slackened off the relative lock nut “A”.

The gasket “F” (fig. 23) guarantees the seal of the gas connection.

It is recommended that it be replaced whenever it shows even the slightest deformation or imperfection.

Using a suitable leak detection fluid solution (e.g. Rocol) check each gas connection one at a time by brushing the solution over the connection. The presence of bubbles will indicate a leak. If there is a leak, tighten the fitting and then recheck for leaks.

IMPORTANT! Do not use a naked flame to test for leaks

Figure 23

Figure 24

1/2" G cylindrical

 

1/2" G cylindrical

(ISO 228-1) male

 

(ISO 228-1) female

C

F

A

 

1/2" G conical

 

(ISO 7-1) male

26

 

 

Image 26
Contents 4Q4 Four Burner Gas Hob Declaration of CE conformity Contents Before Using for the First Time Important Safeguards & Recommendations Features Cooking Points Control PanelUse of the Hob GAS BurnersLighting the Burners Choice of Burner Max 36 cmCorrect USE of TRIPLE-RING Burner Page Glass Surface Cleaning and MaintenanceGeneral Tips Control Knobs Enamelled PartsGAS Taps Burners and Grids Important WarningIt is very important to check that Ignitor S Flame failure probe T Tips For Installation Location Technical Information for the Installer 585 Fastening the Cooktop Ventilation requirements Installation & Service Regulations United Kingdom Gas supply requirementsInstallation to Natural GAS Gas ConnectionGAS Connector Connection to the GAS SupplyConversion to Natural Gas or LPG Replacing the Burner InjectorsTable for the choice of the Injectors Cat II 2H3+Minimum Burner Setting Adjustment Lubrication of the gas tapsElectrical Connection Section of the Supply Cable Type H05V2V2-F Appliance servicing Guarantee Limit of CoverPage Page Gas on glass cooktops