Beckett Genuine Replacement Parts for Improved Burner Performance

Page 22

Replacement Parts

For best performance specify genuine Beckett replacement parts

Item

Part Name

Description

CF1400 Part No.

CF2300 Part No.

1

Oil Valve

Mounted on Junction Box

21789U

21789U

2

Knurled Nut

All models

3666

3666

3

Adjusting plate assembly

w/ cast aluminum door

51213U

51213U

w/ stamped sheet-metal door

5201701U

5201701U

 

 

 

 

 

 

 

4

Fuel pump

B2TA-8245

21313U

21313U

5

Damper motor

2-stage

750601U

750601U

6

Fuel lines

Specify length

 

 

 

 

 

7

Air Proving Switch

2” W.C.

22181U

22181U

8

Timer

Nozzle Valve Delay

21295U

21295U

9

Transformer

12,000 volt

51214

51214

10

Control

Specify

11

Pedestal kit

All models

51193

51193

 

 

 

 

 

12

Coupling hole plug

use with threaded hole

32439U

32439U

13

Rear cover door as-

w/ cast aluminum door*

 

5994U

51204U

sembly

w/ stamped sheet-metal door*

5201301U

5201302U

 

 

 

 

 

 

 

14

Sight glass

All models

 

31346

31346

15

Head assembly

 

 

5978

51203

16

Electrode assembly

All models

 

51212

51212

 

 

8-1/4” long

 

5990082

5990082

17

Ignition leads

11-3/4” long

 

5990116

5990116

15-1/4” long

 

5990152

5990152

 

 

 

 

 

19-1/4” long

 

5990192

5990192

 

 

 

 

 

 

18

Air tube

 

Refer to Figure 4

 

19

Nozzle line assembly

 

Refer to Figure 5

 

 

 

 

 

 

 

20

Coupling

B Pump

21290

21549

21

Blower wheel

CF1400 - 5.59” x 3.09” CF2300 - 6.75” x 3.13”

21268U

21267U

22

Motor Mounting Flange

N/A

31347U

23

Motor

120/208-230 single phase

21401U

21402U

208-230/460 three phase

21638U

21499U

 

 

 

 

120V single phase

752804

752804

 

Motor relay (not shown)

208V single phase

7300

7300

 

 

Three phase

2194301

2194301

 

 

 

 

 

Adjustable flange

See Figure 18 on previous page

* These doors are NOT interchangeable. Please specify when ordering.

22

Image 22
Contents Potential for Fire, Smoke and Asphyxiation Hazards To the Homeowner or Equipment OwnerContents Hazard Definitions General InformationFrozen Plumbing Water Damage Hazard Clearances Pre-Installation ChecklistCombustion Air Supply Fuel Supply Oil Supply Pressure Control RequiredVerify Firing Rate Vent SystemVerify Burner Components Electrical SupplyAir Tube Capacity Versus Firebox Pressure Verify Air Tube± 1/8 Mount the Burner Protect Against Stray Light Lockout Failure to follow theseInstall Nozzle Line Assembly Install NozzleCheck Electrode Settings Maintain Electrode Specifications Mount Air Tube to BurnerInstall Oil Supply To Specifications Set Z DimensionFuel Unit By-pass Plug Factory-Installed Pump Bypass Plug Do not install valves in the return lineOil Supply/Return Lines One-pipe Oil System By-pass LoopBurner Fuel Flow Electrical shock can cause severe personal injury or death Wire the BurnerCan cause severe injury, death, or property damage Typical Burner Sequence of Operation Optional ComponentsTypical Wiring 7505P Typical Burner Sequence of Operation 7184B Control Restricted LockoutCould lead to equipment malfunction and result Tampering with, or bypassing safety controlsPrepare the Burner for Start-up Asphyxiation, explosion or fireCF2300 Initial Indicator Adjustment Plate Settings CF1400 Initial Indicator Adjustment Plate SettingsInitial Head Position Set Appliance Limit Controls Initial Air SettingsPrepare the Fuel Unit for Air Venting Start the Burner Professional Service RequiredDisable Function Explosion and Fire Hazard Set High-fire Air Operating the Burner Set Low-fire Air Annual Professional Service Required Maintenance and ServiceReplacement Parts Annual ServiceBurner Replacement Parts Part Name Description CF1400 Part No CF2300 Part No Oil Valve Mounted on Junction Box 21789USK9930 SK9936 SK9932 Limited Warranty Information
Related manuals
Manual 24 pages 57.78 Kb