Market Forge Industries M24G200A-4SP, M36G300A-4SP, M24G100A-4SP manual Do not Reuse Container

Page 26

APPLICATION INSTRUCTIONS

S-2299

APPLICATION INSTRUCTIONS FOR TOTAL CONCEPT CLEANING OF BOILER

SIZE: 1 Gallon PART NUMBER: 20 - 0307

Fig. 5

Fig. 8

4.Remove the shipping cap, replace it with the pouring cap. Cut the tip of the pouring cap at the first notch to a 45o angle.

5.Install the tubing firmly over the tip of the pouring cap.

Fig. 6

6.Energize compartment to release steam pressure in boiler to “0” PSI before removing pipe plug.

7.Remove the plug from the access port on the steam header pipe inside cabinet doors.

CAUTION: HE7DER PIPE & ACCESS PLUG ARE HOT.

Fig. 7

8.Feed the tubing through the access port in the boiler compartment.

NOTE: A minimum of 12” must be inserted.

Fig. 9

9.Tilt the container, pour the contents into the unit.

10.When empty, refill the container with hot tap water and add to boiler for cleaning. Repeat twice. This additional 2 gallons of water will cause the low water probe to be immersed in cleaner/descaler solution. Replace access plug.

11.After rinsing the container, place tubing inside the bottle, cover with shipping cap, dispose of properly.

DO NOT REUSE CONTAINER.

12.DO NOT ENERGIZE HEATERS. Allow 2 hours for cleaning.

13.After time has elapsed, drain the boiler.

14.Refill the boiler and drain. Repeat this step twice.

15.Bring the boiler to temperature and cycle steam to the cooker compartment to purge cleaner/descaler from the steam supply lines. Repeat this step twice.

16.Boiler is now ready for use.

23

Image 26
Contents GAS Operated Boiler Table of Contents To the Kitchen Manager Introduction HOW to USE this ManualIntroduction Theory of Operation for GAS BoilerGAS Operated Boilers Models Installation InstructionsInstalling Legs LevelingGAS Service Connections Electric Service ConnectionService Connections Gas Operated BoilersLower Deflector Assembly Operating Instructions First Check to be Sure ThatIf GAS Pressure is TOO High AdjustmentsIf GAS Pressure is LOW Setting the Boiler Control Pressure Switches Pressure Control Switch AdjustmentGeneral TROUBL-SHOOTING Trouble Possible Cause RemedyGeneral TROUBL-SHOOTING Testing Procedure Water Control Board Testing ProcedureIllustrated Parts List Item no Part DescriptionPressure Switch Box Control Box Assembly, with and without Cover Plumbing, Left Side Gas Boiler Front View Gas Boiler, 24, 200K Gas Train, 200K BTU Boiler Shown Gas Train, 200K Boiler Shown Electrical Information Electrical Information Cleaning Instructions MaintenanceCleaning the Boiler Maintenance Application Instructions General NotesDo not Reuse Container