Market Forge Industries Gas Operated Boiler, M36G300A-4SP Adjustments, If GAS Pressure is LOW

Page 9

OPERATING INSTRUCTIONS

CAUTION: BE SURE TO READ:

Disconnect The Power Supply to the boiler before servicing or cleaning.

Keep the appliance area free and clear of combustibles.

Do not obstruct the flow of combustion and ventilation air.

Keep this manual for future reference.

Contact the factory, the factory representative, or an authorized service company to perform maintenance and repairs.

In the event of a power failure, no attempt should be made to operate the appliance. Be sure the water switch is in the OFF position.

LIGHTING INSTRUCTION, SPARK PILOT: (Be sure boiler drain valve is closed)

1.Press water switch from OFF to ON.

2.Wait 5 to 10 minutes for water to fill in the boiler (Gauge glass should be 2/3 full).

3.Press the heat switch from ON to OFF and release back to ON position when the low water light goes OFF. Green indicator light will come on (This is necessary to manually reset the unit).

ADJUSTMENTS

A. IF GAS PRESSURE IS LOW:

Check your gas supply line for a restriction. If no restriction exists, check with your Natural gas supplier to provide at least 5” of water column pressure in the gas supply line. If no restriction exists and Propane gas is being used, the tank pressure regulator should be adjusted to supply at least 11” of water column pressure in the gas supply line. If this adjustment cannot be made to your satisfaction, the gas supplier should be noti- fied.

B. IF GAS PRESSURE IS TOO HIGH:

Adjust the pressure regulator on the boiler gas valve to reduce the pressure if Natural gas is being used. If Propane gas is being used, adjust the pressure regulator supplied by the gas supplier. If the regulator cannot be adjusted, notify the gas supplier.

6

Image 9
Contents GAS Operated Boiler Table of Contents Introduction Introduction HOW to USE this ManualTo the Kitchen Manager Theory of Operation for GAS BoilerInstalling Legs Installation InstructionsGAS Operated Boilers Models LevelingElectric Service Connection GAS Service ConnectionsGas Operated Boilers Service ConnectionsLower Deflector Assembly First Check to be Sure That Operating InstructionsAdjustments If GAS Pressure is LOWIf GAS Pressure is TOO High Pressure Control Switch Adjustment Setting the Boiler Control Pressure SwitchesTrouble Possible Cause Remedy General TROUBL-SHOOTINGGeneral TROUBL-SHOOTING Water Control Board Testing Procedure Testing ProcedureItem no Part Description Illustrated Parts ListPressure Switch Box Control Box Assembly, with and without Cover Plumbing, Left Side Gas Boiler Front View Gas Boiler, 24, 200K Gas Train, 200K BTU Boiler Shown Gas Train, 200K Boiler Shown Electrical Information Electrical Information Maintenance Cleaning the BoilerCleaning Instructions Maintenance General Notes Application InstructionsDo not Reuse Container