INSTALLATION INSTRUCTIONS
GAS OPERATED BOILERS
MODELS:
•M24G100A - 4SP
•M24G200A - 4SP
•M36G100A - 4SP
•M36G200A - 4SP
• M36G300A - 4SP
CAUTION: BE SURE TO READ:
►Keep this appliance area free and clear from combustibles.
►Do not obstruct the flow of combustion and ventilation air.
►Keep this manual for future reference.
►This installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas code, ANSI
►This applicance, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electric Code,
►The boiler and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressure in excess of 1/2 psig (3.45 k/PA).
►The boiler must be isolated from the gas supply system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.45 k/PA).
►The wiring diagram label is located on the inside of the
►This product must be installed in a room with adequate air supply.
►Do not place any objects on or directly against the unit as to block air openings into the combustion chamber.
►Clearances from both combustible and
►This unit is serviceable from the front, do not install in such a manner where a service person cannot remove front panels.
INSTALLING LEGS:
Some models are shipped without legs. A separate carton will contain the legs. If your model is received this way, be sure to follow the installation instruction sheet packed with the legs.
LEVELING:
In order for the boiler to drain correctly, it is important to use a level on cabinet top both left and right and
LOWER DEFLECTOR PLATE:
The lower deflector plate must be installed on the boiler. Be sure to follow the installation instructions located on page 4.
1