Burnham FM01FD00B manual Description

Page 105

Appendix A - Figures (continued)

Figure Number

Page Number

Description

Section III - Boiler Assembly Instructions (Knockdown Boiler) (continued)

Figure 25

42

Internal Wiring Harness - Length Adjustment for Penetration Through Side

 

 

of Jacket Front Panel

Figure 26

44

Install Top Corner/Intermediate Panels

Figure 27

44

Install Jacket Front Panel

Figure 28

45

Jacket Split Rear Panel Detail

Figure 29

45

Install Jacket Split Rear Panel

Figure 30a

46

Installing Jacket Top Panels - Viewed From Front

Figure 30b

47

Install Jacket Top Panels - Viewed From Rear

Figure 30c

47

Install Jacket Rear Top Panel - Viewed Front Rear

Figure 31

47

Install Burner Swing Door

Figure 32

49

Install 3rd Pass Flueway Baffles (4 thru 11 Section Boilers Only)

Figure 33

49

Install 2nd Pass Flueway Baffles

Figure 34

50

Secure Burner Swing Door for Tight Perimeter Seal

Figure 35

50

Install Burner Adapter Plate and Burner to Burner Swing Door

Figure 36

51

Burner Adapter Plate Options

Figure 37

52

Install Jacket Front Panel Harness Cover Plates and Logo Plate

Figure 38

52

Purpose of tappings in Supply Manifold

Figure 39

53

Install Standard Trim and Operating Control

Figure 40

53

Control Connections to Internal Wiring Harness

Figure 41

54

Install Probe Low Water Cut-Off

Figure 42

54

Install High Limit Control

Figure 43

55

Install Modulation Control

Figure 44

55

Install Low/High/Low Control

Figure 45

55

Install Modulation Control

Figure 46

56

Install Flue Outlet Damper Assembly

Figure 47

57

Install Jacket Panels for Optional Burner Swing Door Cover

Section IV - Installation Instructions

Figure 48

58

Packaged Boiler Shipping Information

Figure 49a

59

Recommended MPC Minimum Piping - Single Boiler Application

Figure 49b

60

Recommended MPC Minimum Piping - Multiple Boiler Application

Figure 50a

61

Alternate MPC Minimum Piping - Single Boiler Application

Figure 50b

62

Alternate MPC Minimum Piping - Multiple Boiler Application

Figure 51

63

Parallel Piping Conversion

Figure 52

63

Typical Burnham Boiler - Primary-Secondary Loop System

Figure 53

63

Recommended Piping for Combination Heating & Cooling (Refrigeration)

 

 

Systems

Figure 54

64

Discharge Piping for Pressure Relief Valve

Section V - Operating Instructions

Section VI - Service Instructions

Section VII - Burner Specifications

105

Image 105
Contents 101786-01R5-11/10 Ialcastiron.comPrice $5.00 Castings Shipped Loose Field Assembly Knockdown Boiler Equipment Check ListParts Cartons On Bar Number Carton Qty. Req’d. Per Boiler Size Important Information Page Page Table of Contents Section VII Burner Specifications Section VI Service InstructionsSection Viii Repair Parts Rear CoverDimensional Information Section I General Information Table I Dimensional InformationCombustion Table II Ratings/Data Model MPC BoilersSection I General Information Table III Recommended Rear Service ClearanceBoiler Foundation MPC with Rear Outlet Vent Faulty Boiler Burner Operation Section II Cast Iron Block Assembly Instructions Hydrostatic Test Manual or Hydraulic Draw-up Section Assembly Vertical Bracing of Rear Section Page MPC4 DRAW-UP Page Section III Boiler Assembly Instructions Knockdown Boiler Section III Boiler Assembly Instructions KD Boiler Page Table VII Modular Return Water Mixing Tube Rwmt RC Return Water Mixing Tube RC Assembly and Installation Hand Form Support Channel Bracket Table Viii Frame/Bracket Mounting Locations Secure Brackets to Horizontal ChannelRear Section Horizontal Channel Assembly w/Mounting Hardware Mount Rear Section Horizontal Channel to Block Assembly Attachment of Lower Rear Section Bracket to Casting Leg Page Lower Tie Bar Installation Heat Exchanger Insulation One Piece and Modular Wrappers Internal Wiring Harness Components Page Internal Wiring Harness Components Install Protective Edging ‘B’ ‘C’ ‘D’ Table IX Internal Wiring Harness AdjustmentPage Table X Jacket Top Corner / Intermediate Panel Arrangement StepInstall Top Corner / Intermediate Panels Jacket Split Rear Panel Detail Table XI Jacket Top Panel Arrangement Installing Jacket Top Panels Viewed From FrontInstall Jacket Top Panels Viewed From Rear Avoid Breathing Fiber Particulates and Dust Install 2nd Pass Flueway Baffles Secure Burner Swing Door for Tight Perimeter Seal Power Flame ‘JR’ Series Burner Adapter Plate Beckett ‘CF’ Series Burner Adapter PlateBeckett ‘CG’ Series Burner Adapter Plate Purpose of Tappings in Supply Manifold Install Standard Trim Operating Control Install Probe Low Water Cut Off Install Low Fire Hold Control MPC4 & MPC5 Install Jacket Panels for Optional Burner Swing Door Cover Packaged Boiler Shipping Information Section IV Installation InstructionsRecommended MPC Minimum Piping Single Boiler Application Recommended MPC Minimum Piping Multiple Boiler Application Alternate MPC Minimum Piping Single Boiler Application Alternate MPC Minimum Piping Multiple Boiler Application Parallel Piping Conversion Discharge Piping for Pressure Relief Valve Section V Operating Instructions Test Controls Frequent Water Addition Section VI Service Instructions Maintenance of LOW Water Cutoff Devices Operation Combustion Safety Controls Frequency Accomplished by RemarksFuel Valves Table XII Recommended Periodic Testing Check List Table XIIIb Beckett Gas Burner Specifications Section VII Burner SpecificationsTable XIVb Power Flame Gas Burner Specifications Table XIVa Power Flame #2 Oil Burner Specifications500 C1-GO-10 16 / Closed Section Viii Repair Parts Repair Parts Cast Iron Section Assembly MPC Common Bare Boiler Components Repair Parts Common Bare Boiler Components MPC Common Bare Boiler Components Oil Burner Repair Parts Common Bare Boiler ComponentsGas Burner Oil, Gas, Gas/Oil Combo BurnerMPC Front & Center Section Frame Rail Assembly Repair Parts Front & Center Section Frame Rail Assembly MPC Rear Section Frame Rail Assembly Repair Parts Rear Section Frame Rail Assembly MPC Return Water Mixing Tube RC Assembly Required Repair Parts Return Water Mixing Tube RC AssemblyMPC Heat Exchanger Insulation Wrapper Repair Parts Heat Exchanger Insulation Wrapper MPC Internal Wiring Harness Components Repair Parts Internal Wiring Harness Components MPC Jacket Panel Assembly Repair Parts Jacket Panel Assembly MPC Jacket Panel Assembly Repair Parts Jacket Panel Assembly MPC 2nd and 3rd Pass Flueway Baffles Repair Parts MPC 2ND and 3RD Pass Flueway Baffles Page Description 100 Optional Working Pressure Trim 101102 Repair Parts Common Optional Controls Appendix a Figures Description 106 Appendix B Tables Limited Warranty

FM01FD00B specifications

The Burnham FM01FD00B is a remarkable heating solution that combines efficiency, reliability, and advanced technology to meet the demands of modern homes and commercial spaces. Standing out in the crowded market of heating systems, the FM01FD00B is designed for those who prioritize both performance and energy savings.

One of the most significant features of the Burnham FM01FD00B is its advanced combustion technology. The system utilizes a high-efficiency burner that maximizes fuel usage, resulting in lower operating costs and reduced environmental impact. The unit is engineered to provide consistent heat distribution, ensuring that every corner of a room reaches a comfortable temperature quickly and effectively.

In addition to its efficient burning capabilities, the FM01FD00B is compatible with multiple heating mediums, allowing it to adapt to various fuel types, including natural gas and propane. This versatility makes it an excellent choice for homeowners looking for flexible heating options that can cater to their specific needs.

The FM01FD00B also comes equipped with a state-of-the-art control system that offers precise temperature management. Users can easily program their desired heating schedule, ensuring optimal comfort at all times. The intuitive interface allows for easy adjustments, making it simple to maintain a cozy environment whether at home or away.

Another key characteristic is the unit's robust construction. Built with high-quality materials, the Burnham FM01FD00B is designed to withstand harsh conditions and provide lasting performance. The durable exterior is resistant to corrosion, further enhancing its longevity and reliability.

Moreover, the system features built-in safety mechanisms that protect against overheating and other potential hazards, ensuring peace of mind for users. This focus on safety extends to its low emissions, making it an eco-friendly choice for those looking to reduce their carbon footprint.

In conclusion, the Burnham FM01FD00B is a high-efficiency heating solution that excels in performance, adaptability, and safety. Its advanced technologies, robust construction, and user-friendly features make it an ideal choice for anyone seeking a dependable and efficient heating system for their home or business. Whether you prioritize energy savings, reliability, or comfort, the FM01FD00B stands out as a top contender in the heating market.